StimTrack: An open-source software for manual transcranial magnetic stimulation coil positioning

被引:7
|
作者
Ambrosini, Emilia [1 ,2 ]
Ferrante, Simona [1 ]
van de Ruit, Mark [3 ]
Biguzzi, Stefano [1 ]
Colombo, Vera [1 ]
Monticone, Marco [4 ]
Ferriero, Giorgio [2 ]
Pedrocchi, Alessandra [1 ]
Ferrigno, Giancarlo [1 ]
Grey, Michael J. [5 ]
机构
[1] Politecn Milan, Dept Elect Informat & Bioengn, Neuroengn & Med Robot Lab, Milan, Italy
[2] IRCCS, Sci Inst Lissone, Ist Clin Sci Maugeri, Dept Phys & Rehabilitat Med, Lissone, MB, Canada
[3] Delft Univ Technol, Fac Mech Maritime & Mat Engn, Dept Biomech Engn, Delft, Netherlands
[4] Univ Cagliari, Dept Publ Hlth Clin & Mol Med, Cagliari, Italy
[5] Univ East Anglia, Sch Hlth Sci, Acquired Brain Injury Rehabil Alliance, Norwich, Norfolk, England
关键词
Transcranial magnetic stimulation; Motor evoked potential; Coil positioning; Motor cortex; Repeatability; Accuracy; Neuronavigation; Intra and inter-session reliability; INPUT-OUTPUT PROPERTIES; CORTICOSPINAL EXCITABILITY; TMS; RELIABILITY; MUSCLE; MODULATION;
D O I
10.1016/j.jneumeth.2017.09.012
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: During Transcranial Magnetic Stimulation (TMS) experiments researchers often use a neuronavigation system to precisely and accurately maintain coil position and orientation. New method: This study aimed to develop and validate an open-source software for TMS coil navigation. StimTrack uses an optical tracker and an intuitive user interface to facilitate the maintenance of position and orientation of any type of coil within and between sessions. Additionally, online access to navigation data is provided, hereby adding e.g. the ability to start or stop the magnetic stimulator depending on the distance to target or the variation of the orientation angles. Results: StimTrack allows repeatable repositioning of the coil within 0.7 mm for translation and <1 degrees for rotation. Stimulus-response (SR) curves obtained from 19 healthy volunteers were used to demonstrate that StimTrack can be effectively used in a typical experiment. An excellent intra and inter-session reliability (ICC > 0.9) was obtained on all parameters computed on SR curves acquired using StimTrack. Comparison with existing method: StimTrack showed a target accuracy similar to that of a commercial neuronavigation system (BrainSight, Rogue Research Inc.). Indeed, small differences both in position (similar to 0.2 mm) and orientation (<1 degrees) were found between the systems. These differences are negligible given the human error involved in landmarks registration. Conclusions: StimTrack, available as supplementary material, is found to be a good alternative for commercial neuronavigation systems facilitating assessment changes in corticospinal excitability using TMS. StimTrack allows researchers to tailor its functionality to their specific needs, providing added value that benefits experimental procedures and improves data quality. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:97 / 104
页数:8
相关论文
共 50 条
  • [21] Coil model comparison for cerebellar transcranial magnetic stimulation
    Can, M. Kaan
    Laakso, Ilkka
    Nieminen, Jaakko O.
    Murakami, Takenobu
    Ugawa, Yoshikazu
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2019, 5 (01):
  • [22] The impact of repetitive navigated transcranial magnetic stimulation coil positioning and stimulation parameters on human language function
    Nico Sollmann
    Sebastian Ille
    Thomas Obermueller
    Chiara Negwer
    Florian Ringel
    Bernhard Meyer
    Sandro M Krieg
    European Journal of Medical Research, 20
  • [23] Positioning strategies of the transcranial magnetic stimulation
    Shönfeldt-Lecuona, C
    Spitzer, M
    Herwig, U
    NERVENHEILKUNDE, 2003, 22 (04) : 177 - +
  • [24] Positioning System for Transcranial Magnetic Stimulation
    Curta, C.
    Nicu, A.
    Plesa, M.
    Valcu, M.
    Ciupa, R.
    INTERNATIONAL CONFERENCE ON ADVANCEMENTS OF MEDICINE AND HEALTH CARE THROUGH TECHNOLOGY, 2009, 26 : 143 - +
  • [25] A low-cost system for coil tracking during transcranial magnetic stimulation
    Washabaugh, Edward P.
    Krishnan, Chandramouli
    RESTORATIVE NEUROLOGY AND NEUROSCIENCE, 2016, 34 (02) : 337 - 346
  • [26] Cerebellar transcranial magnetic stimulation: The role of coil type from distinct manufacturers
    Spampinato, Danny
    Ibanez, Jaime
    Spanoudakis, Manos
    Hammond, Paul
    Rothwell, John C.
    BRAIN STIMULATION, 2020, 13 (01) : 153 - 156
  • [27] Transcranial magnetic stimulation -: a sandwich coil design for a better sham
    Sommer, J
    Jansen, A
    Dräger, B
    Steinsträter, B
    Breitenstein, C
    Deppe, M
    Knecht, S
    CLINICAL NEUROPHYSIOLOGY, 2006, 117 (02) : 440 - 446
  • [28] Coil optimisation for transcranial magnetic stimulation in realistic head geometry
    Koponen, Lari M.
    Nieminen, Jaakko O.
    Mutanen, Tuomas P.
    Stenroos, Matti
    Ilmoniemi, Risto J.
    BRAIN STIMULATION, 2017, 10 (04) : 795 - 805
  • [29] The Effect of Coil Type and Navigation on the Reliability of Transcranial Magnetic Stimulation
    Fleming, Melanie K.
    Sorinola, Isaac O.
    Newham, Di J.
    Roberts-Lewis, Sarah F.
    Bergmann, Jeroen H. M.
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2012, 20 (05) : 617 - 625
  • [30] Within-subject effect of coil-to-cortex distance on cortical electric field threshold and motor evoked potentials in transcranial magnetic stimulation
    Julkunen, Petro
    Saisanen, Laura
    Danner, Nils
    Awiszus, Friedemann
    Kononen, Mervi
    JOURNAL OF NEUROSCIENCE METHODS, 2012, 206 (02) : 158 - 164