StimTrack: An open-source software for manual transcranial magnetic stimulation coil positioning

被引:7
|
作者
Ambrosini, Emilia [1 ,2 ]
Ferrante, Simona [1 ]
van de Ruit, Mark [3 ]
Biguzzi, Stefano [1 ]
Colombo, Vera [1 ]
Monticone, Marco [4 ]
Ferriero, Giorgio [2 ]
Pedrocchi, Alessandra [1 ]
Ferrigno, Giancarlo [1 ]
Grey, Michael J. [5 ]
机构
[1] Politecn Milan, Dept Elect Informat & Bioengn, Neuroengn & Med Robot Lab, Milan, Italy
[2] IRCCS, Sci Inst Lissone, Ist Clin Sci Maugeri, Dept Phys & Rehabilitat Med, Lissone, MB, Canada
[3] Delft Univ Technol, Fac Mech Maritime & Mat Engn, Dept Biomech Engn, Delft, Netherlands
[4] Univ Cagliari, Dept Publ Hlth Clin & Mol Med, Cagliari, Italy
[5] Univ East Anglia, Sch Hlth Sci, Acquired Brain Injury Rehabil Alliance, Norwich, Norfolk, England
关键词
Transcranial magnetic stimulation; Motor evoked potential; Coil positioning; Motor cortex; Repeatability; Accuracy; Neuronavigation; Intra and inter-session reliability; INPUT-OUTPUT PROPERTIES; CORTICOSPINAL EXCITABILITY; TMS; RELIABILITY; MUSCLE; MODULATION;
D O I
10.1016/j.jneumeth.2017.09.012
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: During Transcranial Magnetic Stimulation (TMS) experiments researchers often use a neuronavigation system to precisely and accurately maintain coil position and orientation. New method: This study aimed to develop and validate an open-source software for TMS coil navigation. StimTrack uses an optical tracker and an intuitive user interface to facilitate the maintenance of position and orientation of any type of coil within and between sessions. Additionally, online access to navigation data is provided, hereby adding e.g. the ability to start or stop the magnetic stimulator depending on the distance to target or the variation of the orientation angles. Results: StimTrack allows repeatable repositioning of the coil within 0.7 mm for translation and <1 degrees for rotation. Stimulus-response (SR) curves obtained from 19 healthy volunteers were used to demonstrate that StimTrack can be effectively used in a typical experiment. An excellent intra and inter-session reliability (ICC > 0.9) was obtained on all parameters computed on SR curves acquired using StimTrack. Comparison with existing method: StimTrack showed a target accuracy similar to that of a commercial neuronavigation system (BrainSight, Rogue Research Inc.). Indeed, small differences both in position (similar to 0.2 mm) and orientation (<1 degrees) were found between the systems. These differences are negligible given the human error involved in landmarks registration. Conclusions: StimTrack, available as supplementary material, is found to be a good alternative for commercial neuronavigation systems facilitating assessment changes in corticospinal excitability using TMS. StimTrack allows researchers to tailor its functionality to their specific needs, providing added value that benefits experimental procedures and improves data quality. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:97 / 104
页数:8
相关论文
共 50 条
  • [1] Analysing concurrent transcranial magnetic stimulation and electroencephalographic data: A review and introduction to the open-source TESA software
    Rogasch, Nigel C.
    Sullivan, Caley
    Thomson, Richard H.
    Rose, Nathan S.
    Bailey, Neil W.
    Fitzgerald, Paul B.
    Farzan, Faranak
    Hernandez-Pavon, Julio C.
    NEUROIMAGE, 2017, 147 : 934 - 951
  • [2] A triangulation-based magnetic resonance image-guided method for transcranial magnetic stimulation coil positioning
    Andoh, Jamila
    Riviere, Denis
    Mangin, Jean-Francois
    Artiges, Eric
    Cointepas, Yann
    Grevent, David
    Paillere-Martinot, Marie-Laure
    Martinot, Jean-Luc
    Cachia, Arnaud
    BRAIN STIMULATION, 2009, 2 (03) : 123 - 131
  • [3] Assessment of standard coil positioning in transcranial magnetic stimulation in depression
    Nauczyciel, Cecilia
    Hellier, Pierre
    Morandi, Xavier
    Blestel, Sophie
    Drapier, Dominique
    Ferre, Jean Christophe
    Barillot, Christian
    Millet, Bruno
    PSYCHIATRY RESEARCH, 2011, 186 (2-3) : 232 - 238
  • [4] A new method for reproducible coil positioning in transcranial magnetic stimulation mapping
    Miranda, PC
    deCarvalho, M
    Conceicao, I
    Luis, MLS
    DuclaSoares, E
    ELECTROMYOGRAPHY AND MOTOR CONTROL-ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1997, 105 (02): : 116 - 123
  • [5] The impact of repetitive navigated transcranial magnetic stimulation coil positioning and stimulation parameters on human language function
    Sollmann, Nico
    Ille, Sebastian
    Obermueller, Thomas
    Negwer, Chiara
    Ringel, Florian
    Meyer, Bernhard
    Krieg, Sandro M.
    EUROPEAN JOURNAL OF MEDICAL RESEARCH, 2015, 20
  • [6] Transcranial magnetic stimulation in therapy studies:: Examination of the reliability of "standard" coil positioning by neuronavigation
    Herwig, U
    Padberg, F
    Unger, J
    Spitzer, M
    Schönfeldt-Lecuona, C
    BIOLOGICAL PSYCHIATRY, 2001, 50 (01) : 58 - 61
  • [7] Accuracy of robotic coil positioning during transcranial magnetic stimulation
    Goetz, Stefan M.
    Kozyrkov, I. Cassie
    Luber, Bruce
    Lisanby, Sarah H.
    Murphy, David L. K.
    Grill, Warren M.
    Peterchev, Angel, V
    JOURNAL OF NEURAL ENGINEERING, 2019, 16 (05)
  • [8] MAGIC: An open-source MATLAB toolbox for external control of transcranial magnetic stimulation devices
    Saatlou, Forough Habibollahi
    Rogasch, Nigel C.
    McNair, Nicolas A.
    Biabani, Mana
    Pillen, Steven D.
    Marshall, Tom R.
    Bergmann, Til O.
    BRAIN STIMULATION, 2018, 11 (05) : 1189 - 1191
  • [9] Effect of coil positioning and orientation of the quadruple butterfly coil during transcranial magnetic stimulation
    Afuwape, Oluwaponmile Faith
    Rastogi, Priyam
    Jiles, David
    AIP ADVANCES, 2021, 11 (01)
  • [10] Open-tES: An open-source stimulator for transcranial electrical stimulation designed for rodent research
    Pedron, Solene
    Dumontoy, Stephanie
    Dimauro, Julien
    Haffen, Emmanuel
    Andrieu, Patrice
    Van Waes, Vincent
    PLOS ONE, 2020, 15 (07):