Linear polarization sensitivity of SeGA detectors

被引:9
作者
Miller, D. [1 ]
Chester, A.
Moeller, V.
Starosta, K.
Vaman, C.
Weisshaar, D.
机构
[1] Michigan State Univ, Natl Superconducting Cyclotron Lab, E Lansing, MI 48824 USA
[2] Michigan State Univ, Dept Phys & Astron, E Lansing, MI 48824 USA
基金
美国国家科学基金会;
关键词
segmented germanium detectors; polarization sensitivity; gamma-ray compton polarimeters;
D O I
10.1016/j.nima.2007.07.141
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Parity is a key observable in nuclear spectroscopy. Linear polarization measurements of gamma-rays are a probe to access the parities of energy levels. Utilizing the segmentation of detectors in the Segmented Germanium Array (SeGA) at the NSCL and analyzing the positions of interaction therein allows the detectors to be used as Compton polarimeters. Unlike other segmented detectors, SeGA detectors are irradiated from the side to utilize the transversal segmentation for better Doppler corrections. Sensitivity in such an orientation has previously been untested. A linear polarization sensitivity Q approximate to 0.14 has been measured in the 350-keV energy range for SeGA detectors using (alpha-gamma correlations from a Cf-249 source. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:713 / 718
页数:6
相关论文
共 15 条
[1]   Simulated response characteristics of Gammasphere [J].
Devlin, M ;
Sobotka, LG ;
Sarantites, DG ;
LaFosse, DR .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 383 (2-3) :506-512
[2]   NUCLEAR SHELL STRUCTURE AT PARTICLE DRIP LINES [J].
DOBACZEWSKI, J ;
HAMAMOTO, I ;
NAZAREWICZ, W ;
SHEIKH, JA .
PHYSICAL REVIEW LETTERS, 1994, 72 (07) :981-984
[3]   The Clover:: a new generation of composite Ge detectors [J].
Duchêne, G ;
Beck, FA ;
Twin, PJ ;
de France, G ;
Curien, D ;
Han, L ;
Beausang, CW ;
Bentley, MA ;
Nolan, PJ ;
Simpson, J .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 432 (01) :90-110
[4]   POLARIZATION MEASUREMENTS ON NUCLEAR GAMMA-RAYS [J].
FAGG, LW ;
HANNA, SS .
REVIEWS OF MODERN PHYSICS, 1959, 31 (03) :711-758
[5]  
Falk F., 1970, Physica Scripta, V1, P13, DOI 10.1088/0031-8949/1/1/002
[6]   Calibration of Compton polarimeters [J].
Jones, GD .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 491 (03) :452-459
[7]   FIGURE OF MERIT FOR GAMMA-RAY POLARIMETERS [J].
LOGAN, BA ;
JONES, RT ;
LJUBICIC, A .
NUCLEAR INSTRUMENTS & METHODS, 1973, 108 (03) :603-604
[8]   Thirty-two-fold segmented germanium detectors to identify γ-rays from intermediate-energy exotic beams [J].
Mueller, WF ;
Church, JA ;
Glasmacher, T ;
Gutknecht, D ;
Hackman, G ;
Hansen, PG ;
Hu, Z ;
Miller, KL ;
Quirin, P .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 466 (03) :492-498
[9]   A SECTORED GE-COMPTON POLARIMETER FOR PARITY ASSIGNMENTS IN PHOTON SCATTERING EXPERIMENTS [J].
SCHLITT, B ;
MAIER, U ;
FRIEDRICHS, H ;
ALBERS, S ;
BAUSKE, I ;
VONBRENTANO, P ;
HEIL, RD ;
HERZBERG, RD ;
KNEISSL, U ;
MARGRAF, J ;
PITZ, HH ;
WESSELBORG, C ;
ZILGES, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 337 (2-3) :416-426
[10]   Gamma-ray polarization sensitivity of the Gammasphere segmented germanium detectors [J].
Schmid, GJ ;
Macchiavelli, AO ;
Asztalos, SJ ;
Clark, RM ;
Deleplanque, MA ;
Diamond, RM ;
Fallon, P ;
Kruecken, R ;
Lee, IY ;
MacLeod, RW ;
Stephens, FS ;
Vetter, K .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 417 (01) :95-110