Clinical paper Mechanical active compression-decompression versus standard mechanical cardiopulmonary resuscitation: A randomised haemodynamic out-of-hospital cardiac arrest study

被引:12
作者
Berve, Per Olav [1 ,2 ,3 ,4 ]
Hardig, Bjarne Madsen [5 ,6 ]
Skalhegg, Tore [3 ]
Kongsgaard, Havard [2 ]
Kramer-Johansen, Jo [1 ,2 ,3 ]
Wik, Lars [2 ,3 ,4 ]
机构
[1] Univ Oslo, Inst Clin Med, Oslo, Norway
[2] Oslo Univ Hosp, Norwegian Natl Advisory Unit Prehosp Emergency Me, Oslo, Norway
[3] Oslo Univ Hosp, Div Prehosp Serv, Air Ambulance Dept, Oslo, Norway
[4] Oslo Univ Hosp, Dept Anaesthesiol, Oslo, Norway
[5] Lund Univ, Fac Med, Sect 2, Clin Sci, Lund, Sweden
[6] Stryker Jolife AB, Lund, Sweden
关键词
Invasive arterial blood pressure; Cardiac arrest; Cardiopulmonary resuscitation; Mechanical chest compression; Active compression decompression; ACD-CPR; Haemodynamic; ETCO2; Capnography; Cerebral oximetry; NIRS; rSO(2); SctO2; TIDAL CARBON-DIOXIDE; CHEST COMPRESSION; VENTILATION DETECTION; PERFUSION-PRESSURE; CEREBRAL OXIMETRY; BLOOD-FLOW; CPR; QUALITY; CAPNOGRAM; INJURIES;
D O I
10.1016/j.resuscitation.2021.10.026
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Active compression-decompression cardiopulmonary resuscitation (ACD-CPR) utilises a suction cup to lift the chest-wall actively during the decompression phase (AD). We hypothesised that mechanical ACD-CPR (Intervention), with AD up to 30 mm above the sternal resting position, would generate better haemodynamic results than standard mechanical CPR (Control). Methods: This out-of-hospital adult non-traumatic cardiac arrest trial was prospective, block-randomised and non-blinded. We included intubated patients with capnography recorded during mechanical CPR. Exclusion criteria were pregnancy, prisoners, and prior chest surgery. The primary endpoint was maximum tidal carbon dioxide partial pressure (pMTCO2) and secondary endpoints were oxygen saturation of cerebral tissue (SctO2), invasive arterial blood pressures and CPR-related injuries. Intervention device lifting force performance was categorised as Complete AD (>30 New
引用
收藏
页码:1 / 10
页数:10
相关论文
共 50 条
  • [21] MECHANICAL CHEST COMPRESSION DEVICE FOR OUT-OF-HOSPITAL CARDIAC ARREST: A NATIONWIDE OBSERVATIONAL STUDY
    Jung, Eujene
    Park, Jeong Ho
    Lee, Sun Young
    Ro, Young Sun
    Hong, Ki Jeong
    Song, Kyoung Jun
    Ryu, Hyun Ho
    Shin, Sang Do
    JOURNAL OF EMERGENCY MEDICINE, 2020, 58 (03) : 424 - 431
  • [22] Inspiratory impedance during active compression-decompression cardiopulmonary resuscitation - A randomized evaluation in patients in cardiac arrest
    Plaisance, P
    Lurie, KG
    Payen, D
    CIRCULATION, 2000, 101 (09) : 989 - 994
  • [23] Mechanical active compression-decompression cardiopulmonary resuscitation (ACD-CPR) versus manual CPR according to pressure of end tidal carbon dioxide (PETCO2) during CPR in out-of-hospital cardiac arrest (OHCA)
    Axelsson, C.
    Karlsson, T.
    Axelsson, A. B.
    Herlitz, J.
    RESUSCITATION, 2009, 80 (10) : 1099 - 1103
  • [24] Filtering mechanical chest compression artefacts from out-of-hospital cardiac arrest data
    Aramendi, E.
    Irusta, U.
    Ayala, U.
    Naas, H.
    Kramer-Johansen, J.
    Eftestol, T.
    RESUSCITATION, 2016, 98 : 41 - 47
  • [25] Effectiveness of mechanical chest compression for out-of-hospital cardiac arrest patients in an emergency department
    Lin, Ching-Kuo
    Huang, Mei-Chin
    Feng, Yu-Tung
    Jeng, Wei-Hsuan
    Chung, Te-Cheng
    Lau, Yu-Wa
    Cheng, Kuang-I
    JOURNAL OF THE CHINESE MEDICAL ASSOCIATION, 2015, 78 (06) : 360 - 363
  • [26] Compression-Only Versus Rescue-Breathing Cardiopulmonary Resuscitation After Pediatric Out-of-Hospital Cardiac Arrest
    Naim, Maryam Y.
    Griffis, Heather M.
    Berg, Robert A.
    Bradley, Richard N.
    Burke, Rita V.
    Markenson, David
    McNally, Bryan F.
    Nadkarni, Vinay M.
    Song, Lihai
    Vellano, Kimberly
    Vetter, Victoria
    Rossano, Joseph W.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2021, 78 (10) : 1042 - 1052
  • [27] Metrics of mechanical chest compression device use in out-of-hospital cardiac arrest
    Levy, Michael
    Kern, Karl B.
    Yost, Dana
    Chapman, Fred W.
    Hardig, Bjarne Madsen
    JOURNAL OF THE AMERICAN COLLEGE OF EMERGENCY PHYSICIANS OPEN, 2020, 1 (06) : 1214 - 1221
  • [28] Compression-only versus standard cardiopulmonary resuscitation in out-of-hospital cardiac arrest: A meta-analysis of randomized controlled trials
    Ahmed, Mushood
    Fatima, Laveeza
    Ahsan, Areeba
    Jain, Hritvik
    Zahra, Rubab
    Asif, Muhammad Hamza
    Jain, Jyoti
    Basit, Jawad
    Ahmed, Raheel
    PERFUSION-UK, 2024,
  • [29] Application of mechanical cardiopulmonary resuscitation devices and their value in out-of-hospital cardiac arrest: A retrospective analysis of the German Resuscitation Registry
    Seewald, Stephan
    Obermaier, Manuel
    Lefering, Rolf
    Bohn, Andreas
    Georgieff, Michael
    Muth, Claus-Martin
    Graesner, Jan-Thorsten
    Masterson, Siobhan
    Scholz, Jens
    Wnent, Jan
    PLOS ONE, 2019, 14 (01):
  • [30] Mechanical versus manual chest compression for out-of-hospital cardiac arrest (PARAMEDIC): a pragmatic, cluster randomised controlled trial
    Perkins, Gavin D.
    Lall, Ranjit
    Quinn, Tom
    Deakin, Charles D.
    Cooke, Matthew W.
    Horton, Jessica
    Lamb, Sarah E.
    Slowther, Anne-Marie
    Woollard, Malcolm
    Carson, Andy
    Smyth, Mike
    Whitfield, Richard
    Williams, Amanda
    Pocock, Helen
    Black, John J. M.
    Wright, John
    Han, Kyee
    Gates, Simon
    LANCET, 2015, 385 (9972) : 947 - 955