Phonophoresis versus ultrasound in the treatment of common musculoskeletal conditions

被引:89
作者
Klaiman, MD [1 ]
Shrader, JA
Danoff, JV
Hicks, JE
Pesce, WJ
Ferland, J
机构
[1] NIH, Dept Rehabil Med, Bethesda, MD 20892 USA
[2] Hosp Special Care, Dept Phys Med, New Britain, CT USA
关键词
musculoskeletal injuries; tendinitis; pressure algometry; corticosteroids;
D O I
10.1097/00005768-199809000-00002
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Purpose: The purpose of this study was to determine whether the pain response after phonophoresis (PH) differs from the pain response after ultrasound (US) alone. Methods: Forty-nine subjects with soft tissue injuries including epicondylitis, tendinitis, and tenosynovitis were randomly assigned (double blinded technique) to PH or US treatment groups. Both groups received 8 min of continuous US at 1.5 w.cm(-2), three times per week for 3 wk. For the PH group a gel containing 0.05% fluocinonide was used as a coupling agent. An identical gel absent the steroid was used for the US group. Subjects indicated their pain level by marking on a visual analog scale (VAS) at the start of treatment and at the end of weeks 1, 2, and 3. Pressure algometry was used to note tolerance to direct pressure over the target tissue. ANOVA for repeated measures was used to analyze data. Results: At the end of 3 wk of treatment, both groups combined showed a significant decrease in pain level and an increase in pressure tolerance (P < 0.05), but there were no differences between groups from the onset of treatment to the end of week 3 (VAS: US 5.5-1.9, PH 5.0-2.0; algometry (involved limb): US 4.7 lb-7.1 Ib, PH 5.1 lb-6.6 Ib). Conclusions: We conclude that US results in decreased pain and increased pressure tolerance in these selected soft tissue injuries. The addition of PH with fluocinonide does not augment the benefits of US used alone.
引用
收藏
页码:1349 / 1355
页数:7
相关论文
共 53 条
[41]  
Muir W S, 1990, Orthop Rev, V19, P351
[42]  
Munting E, 1978, Physiotherapy, V64, P180
[43]   HYDROCORTISONE PHONOPHORESIS - A LITERATURE-REVIEW [J].
NEWMAN, JT ;
NELLERMOE, MD ;
CARNETT, JL .
JOURNAL OF THE AMERICAN PODIATRIC MEDICAL ASSOCIATION, 1992, 82 (08) :432-435
[44]   Reliability of clinical pressure-pain algometric measurements obtained on consecutive days [J].
Nussbaum, EL ;
Downes, L .
PHYSICAL THERAPY, 1998, 78 (02) :160-169
[45]   INFLUENCE OF THERAPEUTIC ULTRASONIC IRRADIATION ON BLOOD-FLOW IN HUMAN CUTANEOUS, SUBCUTANEOUS, AND MUSCULAR TISSUES [J].
PAASKE, WP ;
HOVIND, H ;
SEJRSEN, P .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1973, 31 (04) :389-394
[46]  
POTTENGER FJ, 1989, MIL MED, V154, P355
[47]   RELIABILITY OF THE PRESSURE ALGOMETER AS A MEASURE OF MYOFASCIAL TRIGGER POINT SENSITIVITY [J].
REEVES, JL ;
JAEGER, B ;
GRAFFRADFORD, SB .
PAIN, 1986, 24 (03) :313-321
[48]   Test-retest reliability of patient reports of low back pain [J].
Roach, KE ;
Brown, MD ;
Dunigan, KM ;
Kusek, CL ;
Walas, M .
JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 1997, 26 (05) :253-259
[49]  
TERHAAR GR, 1982, BRIT J CANCER, V45, P172
[50]  
WARREN CG, 1976, ARCH PHYS MED REHAB, V57, P218