Pulse Oximeter Performance during Rapid Desaturation

被引:2
|
作者
Horakova, Lenka [1 ]
Roubik, Karel [1 ]
机构
[1] Czech Tech Univ, Fac Biomed Engn, Dept Biomed Technol, Kladno 27201, Czech Republic
关键词
pulse oximetry; hypoxemia; oxygen saturation; safety limits; avalanche victim; outdoor experiments; CLINICAL-EVALUATION; OXYGEN-SATURATION; SNOW BURIAL; AIR POCKET; ACCURACY; HYPOXIA; RESPIRATION; HYPERCAPNIA; INTUBATION; HYPOXEMIA;
D O I
10.3390/s22114236
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The reliability of pulse oximetry is crucial, especially in cases of rapid changes in body oxygenation. In order to evaluate the performance of pulse oximeters during rapidly developing short periods of concurrent hypoxemia and hypercapnia, 13 healthy volunteers underwent 3 breathing phases during outdoor experiments (39 phases in total), monitored simultaneously by five different pulse oximeters. A significant incongruity in values displayed by the tested pulse oximeters was observed, even when the accuracy declared by the manufacturers were considered. In 28.2% of breathing phases, the five used devices did not show any congruent values. The longest uninterrupted congruent period formed 74.4% of total recorded time. Moreover, the congruent periods were rarely observed during the critical desaturation phase of the experiment. The time difference between the moments when the first and the last pulse oximeter showed the typical study endpoint values of SpO(2) 85% and 75% was 32.1 +/- 23.6 s and 24.7 +/- 19.3 s, respectively. These results suggest that SpO(2) might not be a reliable parameter as a study endpoint, or more importantly as a safety limit in outdoor experiments. In the design of future studies, more parameters and continuous clinical assessment should be included.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Pulse Oximeter
    Oncel, Tumay Umuroglu
    JOURNAL OF THE TURKISH SOCIETY OF INTENSIVE CARE-TURK YOGUN BAKM DERNEGI DERGISI, 2006, 4 (02): : 96 - 106
  • [22] Evaluation of pulse oximeter at the nasal septum during general anesthesia: comparison with finger oximeter
    Oh, Yena
    Kim, Duk Kyung
    Ryu, Dae Kyun
    Choi, Ji Won
    JOURNAL OF ANESTHESIA, 2024, 38 (03) : 364 - 370
  • [23] Performance of a novel reusable pediatric pulse oximeter probe
    King, Carina
    Mvalo, Tisungane
    Sessions, Kristen
    Wilson, Iain
    Walker, Isabeau
    Zadutsa, Beatiwel
    Makwenda, Charles
    Phiri, Tambosi
    Boyd, Nicholas
    Bernstein, Mike
    McCollum, Eric D.
    PEDIATRIC PULMONOLOGY, 2019, 54 (07) : 1052 - 1059
  • [24] Pulse Oximeter Performance, Racial Inequity, and the Work Ahead
    Okunlola, Olubunmi E.
    Lipnick, Michael S.
    Batchelder, Paul B.
    Bernstein, Michael
    Feiner, John R.
    Bickler, Philip E.
    RESPIRATORY CARE, 2022, 67 (02) : 252 - 257
  • [25] EVALUATION OF THE OHMEDA BIOX 3700 PULSE OXIMETER DURING RAPID CHANGES IN ARTERIAL OXYGEN-SATURATION
    BERKO, RS
    KAGLE, DM
    ALEXANDER, CM
    GIUFFRE, M
    GROSS, JB
    ANESTHESIOLOGY, 1986, 65 (3A) : A130 - A130
  • [26] MONITORING OF NOCTURNAL OXYGEN DESATURATION USING PULSE OXIMETER AND APNOMONITOR IN PATIENTS WITH CHRONIC PULMONARY-DISEASE
    MIYAHARA, Y
    MIYAHARA, Y
    NAITO, T
    IKEDA, S
    RESPIRATION, 1995, 62 (06) : 348 - 352
  • [27] PULSE OXIMETER FAILURE DURING GENERAL-ANESTHESIA
    TRIVEDI, NS
    BARKER, SJ
    HYATT, J
    SHAH, NK
    ANESTHESIOLOGY, 1995, 83 (3A) : A473 - A473
  • [28] UTILITY OF THE PULSE OXIMETER DURING CARDIOPULMONARY-RESUSCITATION
    NARANG, VPS
    ANESTHESIOLOGY, 1986, 65 (02) : 239 - 240
  • [29] Desaturation during rapid sequence induction of anaesthesia
    Dawson, J. S.
    ANAESTHESIA, 2010, 65 (09) : 957 - 957
  • [30] Pulse oximeter for homecare
    Lopera, JM
    Díaz, J
    Prieto, MJ
    Nuño, F
    SECOND JOINT EMBS-BMES CONFERENCE 2002, VOLS 1-3, CONFERENCE PROCEEDINGS: BIOENGINEERING - INTEGRATIVE METHODOLOGIES, NEW TECHNOLOGIES, 2002, : 1738 - 1739