The relationship between the cornea and the optic disc

被引:8
|
作者
Kim, J. M. [2 ]
Park, K. H. [1 ]
Kim, S. H. [1 ]
Kang, J. H. [3 ]
Cho, S. W. [2 ]
机构
[1] Seoul Natl Univ, Coll Med, Dept Ophthalmol, Seoul Natl Univ Hosp, Seoul 110744, South Korea
[2] Sungkyunkwan Univ, Sch Med, Dept Ophthalmol, Kangbuk Samsung Hosp, Seoul, South Korea
[3] Kyung Hee Univ, Coll Med, Dept Ophthalmol, EW Neo Med Ctr, Seoul, South Korea
关键词
cornea; cup to disc ratio; optic disc; white to white diameter; NORMAL-TENSION GLAUCOMA; LAMINA-CRIBROSA; AXIAL LENGTH; THICKNESS; EYES; PROGRESSION; SIZE; ASTIGMATISM; PARAMETERS; SCLERA;
D O I
10.1038/eye.2010.98
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective To evaluate the structural relationship between the cornea and the optic disc in normal subjects. Methods This hospital-based observational study included 205 eyes from 205 individuals who were diagnosed as normal at our glaucoma clinic. The subjects underwent an eye examination, optic disc imaging with optic disc photography, optical coherence tomography, IOL master, specular microscopy, and ultrasound corneal pachymetry. Results In univariate regression models (Pearson's correlation coefficient), the cup-to-disc (CD) ratio showed a negative correlation with corneal curvature (r = -0.315, P < 0.001) and central corneal thickness (r = -0.206, P = 0.005), and a positive correlation with white-to-white diameter (horizontal limbus to limbus distance, r - 0.215, P - 0.003). In multiple linear regression models with CD ratio as the dependant parameter, the CD ratio was still significantly associated with corneal curvature (beta = -0.205, P = 0.011) and white-to-white diameter (beta = 0.207, P = 0.010). The central corneal thickness failed to show statistical significance, but did show a negative correlation with borderline significance (beta = -0.133, P = 0.075). Conclusions Eyes with a large CD ratio have large and flat corneas; this may suggest that there is a structural relationship between the cornea and the optic disc. These results can be helpful in analysing the anatomical relationship between the cornea and the optic disc. Eye (2010) 24, 1653-1657; doi: 10.1038/eye.2010.98; published online 23 July 2010
引用
收藏
页码:1653 / 1657
页数:5
相关论文
共 50 条
  • [1] The relationship between the cornea and the optic disc
    J M Kim
    K H Park
    S H Kim
    J H Kang
    S W Cho
    Eye, 2010, 24 : 1653 - 1657
  • [2] Study of correlation between optic disc size and corneal geometry and biomechanics
    da Silva, Renata Siqueira
    Siqueira da Silva, Jorge Augusto
    Fonyat de Lima, Fernanda Bina
    Valbon, Bruno de Freitas
    Salomao, Marcella Quaresma
    Ambrosio Junior, Renato
    REVISTA BRASILEIRA DE OFTALMOLOGIA, 2011, 70 (06) : 349 - 357
  • [3] Relationship between optic disc hemorrhage and corneal hysteresis
    Radcliffe, Nathan M.
    Tracer, Nathaniel
    De Moraes, Carlos Gustavo, V
    Tello, Celso
    Liebmann, Jeffrey M.
    Ritch, Robert
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2020, 55 (03): : 239 - 244
  • [4] Relationship between anterior segment and optic nerve head parameters in healthy subjects
    Cankaya, Ali Bulent
    Ozates, Serdar
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2017, 80 (05) : 285 - 289
  • [5] The prevalence of optic disc pits and their relationship to glaucoma
    Healey, Paul R.
    Mitchell, Paul
    JOURNAL OF GLAUCOMA, 2008, 17 (01) : 11 - 14
  • [6] Relationship between corneal thickness and optic disc damage in glaucoma
    Hewitt, AW
    Cooper, RL
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2005, 33 (02) : 158 - 163
  • [7] Optic Disc Damage Staging System
    Brusini, Paolo
    Zeppieri, Marco
    Tosoni, Claudia
    Parisi, Lucia
    Salvetat, Maria Letizia
    JOURNAL OF GLAUCOMA, 2010, 19 (07) : 442 - 449
  • [8] Relationship between optic disc ovality and horizontal disc tilt in normal young subjects
    Takasaki, Hiroko
    Higashide, Tomomi
    Takeda, Hisashi
    Ohkubo, Shinji
    Sugiyama, Kazuhisa
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2013, 57 (01) : 34 - 40
  • [9] RELATIONSHIP BETWEEN MORPHOMETRIC OPTIC DISC PARAMETERS, SEX AND AXIAL LENGTH
    MIGLIOR, S
    BRIGATTI, L
    VELATI, P
    BALESTRERI, C
    ROSSETTI, L
    BUJTAR, E
    ORZALESI, N
    CURRENT EYE RESEARCH, 1994, 13 (02) : 119 - 124
  • [10] Relationship between cup-disc ratio and optic disc diameter: The Blue Mountains eye study
    Healey, PRJ
    Mitchell, P
    Smith, W
    Wang, JJ
    AUSTRALIAN AND NEW ZEALAND JOURNAL OF OPHTHALMOLOGY, 1997, 25 : S99 - S101