HVAC energy savings, thermal comfort and air quality for occupant-centric control through a side-by-side experimental study

被引:80
作者
Kong, Meng [1 ,2 ]
Dong, Bing [1 ]
Zhang, Rongpeng [2 ]
O'Neill, Zheng [3 ]
机构
[1] Syracuse Univ, Dept Mech & Aerosp Engn, 223 Link Hall, Syracuse, NY 13244 USA
[2] Delos Living LLC, Well Living Lab, 221 First Ave SW Ste 100, Rochester, MN 55902 USA
[3] Texas A&M Univ, J Mike Walker 66 Dept Mech Engn, College Stn, TX 77843 USA
关键词
Occupancy sensing; Occupancy-based control; Side-by-side experiment; Energy savings; Thermal comfort; Indoor air quality; PREDICTIVE CONTROL; SBS SYMPTOMS; PRODUCTIVITY; POLLUTION; BEHAVIOR;
D O I
10.1016/j.apenergy.2021.117987
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Building sensing technologies have evolved rapidly in the last two decades in aid of monitoring building envi-ronment and energy system performance. A series of occupancy sensing systems were developed to track the occupant behavior in the indoor space. Occupancy-based building system control is defined as a control method that adjusts the building system operation schedules and setpoints based on the measured occupant behavior and has been identified as a smart building control strategy that can improve building energy efficiency as well as occupant comfort. Some studies demonstrated energy-saving potential and comfort-maintaining capability from occupancy-based control. This study adopted a first-of-its-kind side-by-side experimental approach to quantify the performance of the occupancy-based control in commercial buildings. Three state-of-the-art occupancy sensing technologies were integrated into the real-time Heating, Ventilation, and Air-Conditioning (HVAC) system control in this study. Their detection accuracy and its effectiveness on energy-saving and thermal comfort were analyzed. It was found that the occupancy-based control can maintain good thermal comfort and perceived indoor air quality with a satisfaction ratio greater than 80%. Although the daily energy-saving varied with oc-cupancy sensor accuracy and outdoor environment conditions, the weekly averaged energy saving was between 17 and 24%.
引用
收藏
页数:19
相关论文
共 42 条
  • [1] Occupancy-based zone-level VAV system control implications on thermal comfort, ventilation, indoor air quality and building energy efficiency
    Anand, Prashant
    Sekhar, Chandra
    Cheong, David
    Santamouris, Mattheos
    Kondepudi, Sekhar
    [J]. ENERGY AND BUILDINGS, 2019, 204
  • [2] [Anonymous], 2016, ASHRAE STANDARD 621
  • [3] [Anonymous], 2007, GREEN SCH ATTRIBUTES, DOI [10.17226/11756, DOI 10.17226/11756]
  • [4] [Anonymous], 2018, EXPLORING OCCUPANT B, DOI DOI 10.1007/978-3-319-61464-9
  • [5] [Anonymous], LEVENBERG MARQUARDT
  • [6] [Anonymous], FIT DATA SHALLOW NEU
  • [7] ASHRAE, 2019, 6212019 ANSIASHRAE
  • [8] ASHRAE, 2005, ASHRAE HDB
  • [9] Ashrae A., 2017, ASHRAE Standard, 55-201 7-Thermal Environmental Conditions for Human Occupancy, 55-201 7
  • [10] Effects of pollution from personal computers on perceived air quality, SBS symptoms and productivity in offices
    Bakó-Biró, Z
    Wargocki, P
    Weschler, CJ
    Fanger, PO
    [J]. INDOOR AIR, 2004, 14 (03) : 178 - 187