The implant thread as a retention element in cortical bone: the effect of thread size and thread profile: a finite element study

被引:152
|
作者
Hansson, S
Werke, M
机构
[1] Astra Tech AB, Dept Res & Dev, S-43121 Molndal, Sweden
[2] Swedish Inst Prod Engn Res, S-43153 Molndal, Sweden
关键词
thread profile; thread size; stress; bone; implant; SINGLE TOOTH IMPLANTS; CONICAL FIXTURE DESIGN; ORAL IMPLANTS; FIXATION; BEHAVIOR; SMOOTH; TISSUE; STRAIN;
D O I
10.1016/S0021-9290(03)00164-7
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Assuming that high stress peaks in the bone can trigger bone resorption a screw-shaped bone implant should be given such a design that the peak stresses arising in the bone, as a result of a certain load, are minimized. Using idealized assumptions the aim of the study was to analyse the effect of variations of the size and the profile of the thread of an axially loaded, screw-shaped, bone implant upon the magnitude of the stress peaks in cortical bone. The investigation was performed by means of axisymmetric finite element analysis. It was found that the shape of the thread profile has a profound effect upon the magnitude of the stresses in the bone and that very small threads of a favourable profile can be quite effective. (C) 2003 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1247 / 1258
页数:12
相关论文
共 50 条
  • [1] The Effect of Dental Implant Materials and Thread Profiles-A Finite Element and Statistical Study
    Shafi, Aisyah Ahmad
    Kadir, Mohammed Rafiq Abdul
    Sulaiman, Eshamsul
    Abu Kasim, Noor Hayaty
    Abu Kassim, Noor Lide
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2013, 3 (04) : 509 - 513
  • [2] Biomechanical Effect of an Exposed Dental Implant's First Thread: A Three-Dimensional Finite Element Analysis Study
    Hudieb, Malik Ismail
    Wakabayashi, Noriyuki
    Abu-Hammad, Osama Abdullah
    Kasugai, Shohei
    MEDICAL SCIENCE MONITOR, 2019, 25 : 3933 - 3940
  • [3] Impact of screw thread shape on stress transfer in bone: a finite element study
    Tetteh, Emmanuel
    McCullough, Matthew B. A.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2020, 23 (09) : 518 - 523
  • [4] Optimal design of thread height and width on an immediately loaded cylinder implant: A finite element analysis
    Ao, Jianhua
    Li, Tao
    Liu, Yanpu
    Ding, Yin
    Wu, Guofeng
    Hu, Kaijin
    Kong, Liang
    COMPUTERS IN BIOLOGY AND MEDICINE, 2010, 40 (08) : 681 - 686
  • [5] Analysis of the Effect of Thread Depth in Four Different Thread Designs on the Stress Distribution at the Implant-bone Interface Using Finite Element Analysis - A Comparative Three-Dimensional In vitro Study
    Patwari, Swati
    Sahu, Jeeban
    Samanta, Satyaki
    Bharti, Shreya
    Saha, Dipanwita
    Manna, Rohan
    JOURNAL OF THE INTERNATIONAL CLINICAL DENTAL RESEARCH ORGANIZATION, 2024, 16 (01) : 48 - 54
  • [6] Effect of thread size on the implant neck area: preliminary results at 1 year of function
    Kang, Young-Il
    Lee, Dong-Won
    Park, Kwang-Ho
    Moon, Ik-Sang
    CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (10) : 1147 - 1151
  • [7] The influence of implant body and thread design of mini dental implants on the loading of surrounding bone: a finite element analysis
    Toth, Arpad
    Hasan, Istabrak
    Bourauel, Christoph
    Mundt, Torsten
    Biffar, Reiner
    Heinemann, Friedhelm
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2017, 62 (04): : 393 - 405
  • [8] Selection of the implant thread pitch for optimal biomechanical properties: A three-dimensional finite element analysis
    Kong, Liang
    Zhao, Yunzhuan
    Hu, Kaijin
    Li, Dehua
    Zhou, Hongzhi
    Wu, Ziyan
    Liu, Baolin
    ADVANCES IN ENGINEERING SOFTWARE, 2009, 40 (07) : 474 - 478
  • [9] Effect of screw thread length on stiffness of proximal humerus locking plate constructs: A finite element study
    Le, Louise
    Jabran, Ali
    Peach, Chris
    Ren, Lei
    MEDICAL ENGINEERING & PHYSICS, 2019, 63 : 79 - 87
  • [10] Evaluation of the cylinder implant thread height and width: A 3-dimensional finite element analysis
    Kong, Liang
    Hu, Kaijin
    Li, Dehua
    Song, Yingliang
    Yang, Jin
    Wu, Ziyan
    Liu, Baolin
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2008, 23 (01) : 65 - 74