Design and Simulation Study of Excitation Coil System with Different Array Configurations for Magnetic Particle Imaging Application

被引:0
作者
Birahim, Muhd Fikri Shahkhirin [1 ]
Othman, Nurmiza [1 ,2 ]
Sapuan, Syarfa Zahirah [1 ,2 ]
Tomari, Mohd Razali Md [1 ,2 ]
机构
[1] Univ Tun Hussein Onn Malaysia, Fac Elect & Elect Engn, Batu Pahat 86400, Johor, Malaysia
[2] Univ Tun Hussein Onn Malaysia, Ctr Electromagnet Compatibil EMC, Batu Pahat 86400, Johor, Malaysia
来源
INTERNATIONAL JOURNAL OF INTEGRATED ENGINEERING | 2020年 / 12卷 / 03期
关键词
Magnetic Particle Imaging (MPI); Magnetic nanoparticles (MNPs); 3D analysis; COPPER; RESOLUTION; CORE;
D O I
10.30880/ijie.2020.12.03.032
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Magnetic Particle Imaging (MPI) is a tomographic imaging method has been introduced for three-dimensional (3D) imaging of human body with some potential applications such as magnetic hyperthermia and cancer imaging. It involves three important elements; tracer development using magnetic nanoparticles (MNPs), hardware realization (scanner using excitation and pickup coils), and image reconstruction optimization. Their combination will produce a high-quality image taken from any biological tissue in the human body based on the secondary magnetic field signal from the magnetized MNPs that are injected into human body. A homogeneous and adequate magnetic field strength from an excitation coil is needed to enhance the quality of the secondary signal. However, the complex surface topography of human body and physical properties of an excitation coil influence the strength and the homogeneity of the magnetic field generation at the MNPs. Therefore, this paper presents a new concept of excitation coil configuration to improve the magnetic field strength and the homogeneity to obtain better magnetization of MNPs to be detected in MPI. Two designs will be proposed with variation in physical properties and coil arrangement based on simulation study that will be carried out by using ANSYS Maxwell to generate magnetic field strength and homogeneity towards the targeted distance of 10 mm - 50 mm below the coils. The obtained magnetic field from the simulation was validated by the mathematical calculation using Biot-Savart Law equation. As a result, the new concept of excitation coil configuration proposed can be used to improve the MPI scanner system performance for various medical application.
引用
收藏
页码:278 / 286
页数:10
相关论文
共 29 条
  • [1] Abdulkareem S, 2017, INT J INTEGR ENG, V9, P39
  • [2] Ann HJ, 2017, INT J INTEGR ENG, V9, P54
  • [3] [Anonymous], ARABIAN J CHEM
  • [4] [Anonymous], J PHYS D
  • [5] Bringout G, 2013, 2013 INT WORKSH MAGN
  • [6] Bringout G., 2015, IEEE Trans. Magn., V51, P1
  • [7] Buzug T. M., 2013, BIOMED TECH ENG, V58
  • [8] Copper Better than Silver: Electrical Resistivity of the Grain-Free Single-Crystal Copper Wire
    Cho, Yong Chan
    Lee, Seunghun
    Ajmal, Muhammad
    Kim, Won-Kyung
    Cho, Chae Ryong
    Jeong, Se-Young
    Park, Jeung Hun
    Park, Sang Eon
    Park, Sungkyun
    Pak, Hyuk-Kyu
    Kim, Hyoung Chan
    [J]. CRYSTAL GROWTH & DESIGN, 2010, 10 (06) : 2780 - 2784
  • [9] Tomographic imaging using the nonlinear response of magnetic particles
    Gleich, B
    Weizenecker, R
    [J]. NATURE, 2005, 435 (7046) : 1214 - 1217
  • [10] 2D Images Recorded With a Single-Sided Magnetic Particle Imaging Scanner
    Graefe, Ksenija
    von Gladiss, Anselm
    Bringout, Gael
    Ahlborg, Mandy
    Buzug, Thorsten M.
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2016, 35 (04) : 1056 - 1065