摘要
The use of magnesium and its alloys as biodegradable metallic implant materials requires that their corrosion behavior can be controlled. We tailored the Mg release kinetics and cell adhesion properties of commercially pure Mg by chemical surface treatments in simulated body fluid, in Dulbecco's Modified Eagle's cell culture medium in the presence or absence of fetal bovine serum (FBS), or in 100% FBS. He La cells were cultured for 24 h on these Mg surfaces to characterize their biocompatibility. Cell density on all treated surfaces was significantly increased compared with a polished Mg surface, where almost no cells survived. This low biocompatibility of pure Mg was not caused by the high Mg ion release with concentrations of up to 300 mg/L in the cell culture medium after 24 h, as cells grown on a glass substrate showed no adverse reactions to high Mg ion concentrations. Rather, the most critical factor for cell adhesion was a sufficiently reduced initial dissolution rate of the surface. A comparison among all surface treatments showed that an incubation of the Mg samples in cell culture medium gave the lowest dissolution rate and resulted in the best cell adhesion and spreading behavior. (C) 2010 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 96B: 84-90, 2011.
引用
收藏
页码:84 / 90
页数:7
相关论文
共 27 条
[1]   Spontaneous and biomimetic apatite formation on pure magnesium [J].
Cortes, D. A. ;
Lopez, H. Y. ;
Mantovani, D. .
THERMEC 2006, PTS 1-5, 2007, 539-543 :589-+
[2]   The preparation, cytocompatibility, and in vitro biodegradation study of pure β-TCP on magnesium [J].
Geng, F. ;
Tan, L. L. ;
Jin, X. X. ;
Yang, J. Y. ;
Yang, K. .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2009, 20 (05) :1149-1157
[3]   In vitro corrosion and biocompatibility of binary magnesium alloys [J].
Gu, Xuenan ;
Zheng, Yufeng ;
Cheng, Yan ;
Zhong, Shengping ;
Xi, Tingfei .
BIOMATERIALS, 2009, 30 (04) :484-498
[4]   Biocorrosion of magnesium alloys: a new principle in cardiovascular implant technology? [J].
Heublein, B ;
Rohde, R ;
Kaese, V ;
Niemeyer, M ;
Hartung, W ;
Haverich, A .
HEART, 2003, 89 (06) :651-656
[5]   Precipitation control of calcium phosphate on pure magnesium by anodization [J].
Hiromoto, Sachiko ;
Shishido, Tamao ;
Yamamoto, Akiko ;
Maruyama, Norio ;
Somekawa, Hidetoshi ;
Mukai, Toshiji .
CORROSION SCIENCE, 2008, 50 (10) :2906-2913
[6]   Control of degradation rate of bioabsorbable magnesium by anodization and steam treatment [J].
Hiromoto, Sachiko ;
Yamamoto, Akiko .
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2010, 30 (08) :1085-1093
[7]   High corrosion resistance of magnesium coated with hydroxyapatite directly synthesized in an aqueous solution [J].
Hiromoto, Sachiko ;
Yamamoto, Akiko .
ELECTROCHIMICA ACTA, 2009, 54 (27) :7085-7093
[8]   Evaluation of cyto-toxicity and corrosion behavior of alkali-heat-treated magnesium in simulated body fluid [J].
Li, LC ;
Gao, JC ;
Wang, Y .
SURFACE & COATINGS TECHNOLOGY, 2004, 185 (01) :92-98
[9]   The development of binary Mg-Ca alloys for use as biodegradable materials within bone [J].
Li, Zijian ;
Gu, Xunan ;
Lou, Siquan ;
Zheng, Yufeng .
BIOMATERIALS, 2008, 29 (10) :1329-1344
[10]   Effect of surface pre-treatments on biocompatibility of magnesium [J].
Lorenz, Carla ;
Brunner, Johannes G. ;
Kollmannsberger, Philip ;
Jaafar, Leila ;
Fabry, Ben ;
Virtanen, Sannakaisa .
ACTA BIOMATERIALIA, 2009, 5 (07) :2783-2789