Medipix detectors in radiation therapy for advanced quality-assurance

被引:12
|
作者
Rosenfeld, Anatoly [1 ]
Alnaghy, Saree [1 ]
Petasecca, Marco [1 ]
Cutajar, Dean [1 ]
Lerch, Michael [1 ]
Pospisil, Stanislav [2 ]
Giacometti, Valentina [3 ]
Schulte, Reinhard [4 ]
Rosso, Valeria [5 ,6 ]
Wuerl, Matthias [7 ]
Granja, Carlos [8 ]
Martisikova, Maria [9 ,10 ,11 ]
Parodi, Katia [7 ]
机构
[1] Univ Wollongong, Ctr Med Radiat Phys, Wollongong, NSW, Australia
[2] Czech Tech Univ, Inst Expt & Appl Phys, Prague, Czech Republic
[3] Queens Univ Belfast, Sch Med Dent & Biomed Sci, Belfast, Antrim, North Ireland
[4] Loma Linda Univ, Sch Med, Loma Linda, CA USA
[5] Univ Pisa, Dept Phys, Pisa, Italy
[6] Ist Nazl Fis Nucl, Sez Pisa, Pisa, Italy
[7] Ludwig Maximilians Univ Munchen, Dept Med Phys, Munich, Germany
[8] Advacam, Prague, Czech Republic
[9] German Canc Res Ctr, Heidelberg, Germany
[10] Heidelberg Inst Radiat Oncol, Heidelberg, Germany
[11] Natl Ctr Radiat Res Oncol, Heidelberg, Germany
关键词
Medipix; Quality assurance; Semiconductor detectors; Radiotherapy; Particle therapy; CARBON ION-BEAMS; CHARGED-PARTICLE; OCULAR MELANOMA; PROTON-BEAM; IN-BEAM; TIMEPIX; SYSTEM; VISUALIZATION; DOSIMETRY; PATH;
D O I
10.1016/j.radmeas.2019.106211
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Spectroscopy-based photon-counting detector systems, Medipix, have many applications in medicine. Medipix detectors benefit from providing energy information as well as high spatial resolution. In this article, a review of Medipix detector technology applied to medicine and imaging techniques are presented. The technology has been used to develop quality assurance (QA) measurement devices in radiation-based treatments. A gamma camera system for radiotherapy has been developed to measure dose delivered to prostate treatments in realtime. The advantage of a high-resolution detector has been utilized in proton and heavy ion therapy for dose QA, measuring the charge particle spectra, and beam geometry for mini-beams. Applications in medical imaging using helium ion beams have been investigated to replace CT for ion beam radiotherapy. This technique provides many advantages over conventional CT such as high-resolution imaging and spectroscopy-based information for planning in helium ion treatments. The Medipix technology has shown it can be broadly applied in radiation and particle therapy applications for accurate QA as well as proving high-resolution imaging in medicine.
引用
收藏
页数:18
相关论文
共 50 条
  • [31] External dosimetry audit for quality assurance of carbon-ion radiation therapy clinical trials
    Mizuno, Hideyuki
    Fukumura, Akifumi
    Kanematsu, Nobuyuki
    Yonai, Shunsuke
    Shirai, Toshiyuki
    Yusa, Ken
    Yanou, Toshihiro
    Suga, Masaki
    Mizota, Manabu
    Minohara, Shinichi
    Kanai, Tatsuaki
    Kamada, Tadashi
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (01): : 31 - 36
  • [32] A dedicated cloud system for real-time upfront quality assurance in pediatric radiation therapy
    Meroni, Silvia
    Cavatorta, Claudia
    Barra, Salvina
    Cavagnetto, Francesca
    Scarzello, Giovanni
    Scaggion, Alessandro
    Pecori, Emilia
    Diletto, Barbara
    Alessandro, Ombretta
    Massimino, Maura
    Gianolini, Stefano
    Pignoli, Emanuele
    Gandola, Lorenza
    STRAHLENTHERAPIE UND ONKOLOGIE, 2019, 195 (09) : 843 - 850
  • [33] Definition of parameters for quality assurance of flattening filter free (FFF) photon beams in radiation therapy
    Fogliata, A.
    Garcia, R.
    Knoos, T.
    Nicolini, G.
    Clivio, A.
    Vanetti, E.
    Khamphan, C.
    Cozzi, L.
    MEDICAL PHYSICS, 2012, 39 (10) : 6455 - 6464
  • [34] Quality assurance of intensity modulated radiation therapy treatment planning using head and neck phantom
    Zahra
    Rehman, Jalil ur
    Asghar, H. M. Noor ul Huda Khan
    Ahmad, Nisar
    Gilani, Zaheer Abbas
    Nasar, Gulfam
    Akhter, Malik M.
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2019, 18 (03) : 239 - 245
  • [35] Radiation therapy quality assurance in clinical trials - Global harmonisation group
    Melidis, Christos
    Bosch, Walter R.
    Izewska, Joanna
    Fidarova, Elena
    Zubizarreta, Eduardo
    Ishikura, Satoshi
    Followill, David
    Galvin, James
    Xiao, Ying
    Ebert, Martin A.
    Kron, Tomas
    Clark, Catharine H.
    Miles, Elizabeth A.
    Aird, Edwin G. A.
    Weber, Damien C.
    Ulin, Kenneth
    Verellen, Dirk
    Hurkmans, Coen W.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 (03) : 327 - 329
  • [36] A national survey on technology and quality assurance for stereotactic body radiation therapy
    Marino, Carmelo
    Garibaldi, Cristina
    Veronese, Ivan
    Carbonini, Claudia
    Russo, Serenella
    Stasi, Michele
    Mancosu, Pietro
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 65 : 6 - 14
  • [37] X-Tream quality assurance in synchrotron X-ray microbeam radiation therapy
    Fournier, Pauline
    Cornelius, Iwan
    Donzelli, Mattia
    Requardt, Herwig
    Nemoz, Christian
    Petasecca, Marco
    Brauer-Krisch, Elke
    Rosenfeld, Anatoly
    Lerch, Michael
    JOURNAL OF SYNCHROTRON RADIATION, 2016, 23 : 1180 - 1190
  • [38] Effects of Cathode Ray Tube Display Formats on Quality-Assurance Auditor's Performance
    Ramadan, Mohamed
    Mohamed, Ahamed
    El-Hariry, Hussien
    HUMAN FACTORS AND ERGONOMICS IN MANUFACTURING & SERVICE INDUSTRIES, 2010, 20 (01) : 61 - 72
  • [39] Daily quality assurance phantom for ultrasound image guided radiation therapy
    Drever, Laura
    Hilts, Michelle
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2007, 8 (03): : 126 - 136
  • [40] Design of an anthropomorphic intensity modulated radiation therapy quality assurance phantom
    Radford, DA
    Followill, DS
    Hanson, WF
    PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 197 - 200