Medipix detectors in radiation therapy for advanced quality-assurance

被引:12
|
作者
Rosenfeld, Anatoly [1 ]
Alnaghy, Saree [1 ]
Petasecca, Marco [1 ]
Cutajar, Dean [1 ]
Lerch, Michael [1 ]
Pospisil, Stanislav [2 ]
Giacometti, Valentina [3 ]
Schulte, Reinhard [4 ]
Rosso, Valeria [5 ,6 ]
Wuerl, Matthias [7 ]
Granja, Carlos [8 ]
Martisikova, Maria [9 ,10 ,11 ]
Parodi, Katia [7 ]
机构
[1] Univ Wollongong, Ctr Med Radiat Phys, Wollongong, NSW, Australia
[2] Czech Tech Univ, Inst Expt & Appl Phys, Prague, Czech Republic
[3] Queens Univ Belfast, Sch Med Dent & Biomed Sci, Belfast, Antrim, North Ireland
[4] Loma Linda Univ, Sch Med, Loma Linda, CA USA
[5] Univ Pisa, Dept Phys, Pisa, Italy
[6] Ist Nazl Fis Nucl, Sez Pisa, Pisa, Italy
[7] Ludwig Maximilians Univ Munchen, Dept Med Phys, Munich, Germany
[8] Advacam, Prague, Czech Republic
[9] German Canc Res Ctr, Heidelberg, Germany
[10] Heidelberg Inst Radiat Oncol, Heidelberg, Germany
[11] Natl Ctr Radiat Res Oncol, Heidelberg, Germany
关键词
Medipix; Quality assurance; Semiconductor detectors; Radiotherapy; Particle therapy; CARBON ION-BEAMS; CHARGED-PARTICLE; OCULAR MELANOMA; PROTON-BEAM; IN-BEAM; TIMEPIX; SYSTEM; VISUALIZATION; DOSIMETRY; PATH;
D O I
10.1016/j.radmeas.2019.106211
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Spectroscopy-based photon-counting detector systems, Medipix, have many applications in medicine. Medipix detectors benefit from providing energy information as well as high spatial resolution. In this article, a review of Medipix detector technology applied to medicine and imaging techniques are presented. The technology has been used to develop quality assurance (QA) measurement devices in radiation-based treatments. A gamma camera system for radiotherapy has been developed to measure dose delivered to prostate treatments in realtime. The advantage of a high-resolution detector has been utilized in proton and heavy ion therapy for dose QA, measuring the charge particle spectra, and beam geometry for mini-beams. Applications in medical imaging using helium ion beams have been investigated to replace CT for ion beam radiotherapy. This technique provides many advantages over conventional CT such as high-resolution imaging and spectroscopy-based information for planning in helium ion treatments. The Medipix technology has shown it can be broadly applied in radiation and particle therapy applications for accurate QA as well as proving high-resolution imaging in medicine.
引用
收藏
页数:18
相关论文
共 50 条
  • [21] Quality assurance of helical tomotherapy intensity modulated radiation therapy
    Xu, Shouping
    Deng, Xiaowu
    Dai, Xiangkun
    Wang, Lianyuan
    Wang, Yunlai
    Xie, Chuanbin
    Ge, Ruigang
    Gong, Hanshun
    APCMBE 2008: 7TH ASIAN-PACIFIC CONFERENCE ON MEDICAL AND BIOLOGICAL ENGINEERING, 2008, 19 : 447 - +
  • [22] Quality Assurance for AI-Based Applications in Radiation Therapy
    Claessens, Michael
    Oria, Carmen Seller
    Brouwer, Charlotte L.
    Ziemer, Benjamin P.
    Scholey, Jessica E.
    Lin, Hui
    Witztum, Alon
    Morin, Olivier
    El Naqa, Issam
    Van Elmpt, Wouter
    Verellen, Dirk
    SEMINARS IN RADIATION ONCOLOGY, 2022, 32 (04) : 421 - 431
  • [23] Patterns of quality assurance and treatment planning for stereotactic body radiation therapy in India - A survey
    Sharma, Smriti
    Upreti, Ritu Raj
    Kinhikar, Rajesh A.
    Sahani, G.
    Sharma, P. K. Dash
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2024, 20 (06)
  • [24] Independent dose calculations for commissioning, quality assurance and dose reconstruction of PBS proton therapy
    Meier, G.
    Besson, R.
    Nanz, A.
    Safai, S.
    Lomax, A. J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (07): : 2819 - 2836
  • [25] A computer-assisted quality-assurance model for burn intensive care applications
    Pallua, N
    Gieseke, R
    Sobottka, HG
    Machens, HG
    Berger, A
    LANGENBECKS ARCHIV FUR CHIRURGIE, 1996, 381 (03): : 155 - 159
  • [26] A comprehensive and efficient daily quality assurance for PBS proton therapy
    Actis, O.
    Meer, D.
    Koenig, S.
    Weber, D. C.
    Mayor, A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (05): : 1661 - 1675
  • [27] Quality assurance in proton beam therapy using a plastic scintillator and a commercially available digital camera
    Almurayshid, Mansour
    Helo, Yusuf
    Kacperek, Andrzej
    Griffiths, Jennifer
    Hebden, Jem
    Gibson, Adam
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2017, 18 (05): : 210 - 219
  • [28] SOLED STATE DETECTORS FOR QUALITY ASSURANCE IN BRACHYTHERAPY
    Marinello, Ginette
    RADIOTHERAPY AND BRACHYTHERAPY, 2009, : 227 - 237
  • [29] A Quality-Assurance guide for the evaluation of mathematical models used to calculate the consequences of Major Hazards
    Vergison, E
    JOURNAL OF HAZARDOUS MATERIALS, 1996, 49 (2-3) : 281 - 297
  • [30] On the use of computed radiography plates for quality assurance of intensity modulated radiation therapy dose distributions
    Day, R. A.
    Sankar, A. P.
    Nailon, W. H.
    MacLeod, A. S.
    MEDICAL PHYSICS, 2011, 38 (02) : 632 - 645