Effective dose equivalent and effective dose for photon exposures from point and disk sources on the floor

被引:6
作者
Kim, CH [1 ]
Reece, WD [1 ]
Poston, JW [1 ]
机构
[1] Texas A&M Univ, Dept Nucl Engn, College Stn, TX 77843 USA
来源
HEALTH PHYSICS | 1998年 / 75卷 / 02期
关键词
Monte Carlo; dose equivalent; effective; photons; phantom;
D O I
10.1097/00004032-199808000-00008
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A complete set of H-E and E values were calculated for photon exposures from point and disk sources on the floor using the MCNP code and a "hermaphroditic" phantom. It was found that a male can receive a higher H-E or health risks than a female by a factor of two from an identical point source on the floor when source distance is less than 50 cm. Conversely, if the source distance becomes larger than 100 cm, the female receives H-E higher than the male by up to 40%. For identical sources, both the male and female experience significantly higher H-E from front-located sources than from back- or side-located sources. For a 100 cm source distance, male H-E from a front-located source is greater than that from a side-located source by factors of 4, 3, and 2 for 0.08, 0.3, and 1.0 MeV photons, respectively. In the female cases, the differences are somewhat smaller but still differ by factors of 3, 2, and 1.7. It was also found that both the highest male and female H-E values occur when a source is within 40-60 cm in front of the phantom. The maximum male H-E is 1.8 x 10(-18), 6.6 x 10(-18), and 2.1 x 10(-17) Sv per photon emission for 0.08, 0.3, and 1.0 MeV photons, respectively. For females, these maximum values are slightly smaller, 1.4 x 10(-18), 5.3 x 10(-18), and 1.9 x 10(-17) Sv/photon, respectively. Tissue kerma free-in-air at 100 cm above a disk source (K-tissue) was found to greatly overestimate H-E if the source radius is less than 200 cm. For radii larger than 200 cm, the K-tissue gives a relatively better estimate of H-E, overestimating by not more than 100%. The point source H-E values were directly integrated to estimate H-E for simple nonself-shielding sources such as disk, circle, and line sources. This simple approach was found to overestimate H-E by less than 10% for these irradiation geometries. Finally, the comparison of H-E and E showed that for most cases these values are almost identical. For point sources, when source distance is larger than 50 cm, the difference between H-E and E was always less than 23% over photon energies between 0.08 and 1.0 MeV. For disk sources of radius larger than 50 cm, the difference was even smaller (<12%).
引用
收藏
页码:170 / 178
页数:9
相关论文
共 50 条
[31]   Dose coefficients of percentile-specific computational phantoms for photon external exposures [J].
Yeom, Yeon Soo ;
Han, Haegin ;
Choi, Chansoo ;
Shin, Bangho ;
Kim, Chan Hyeong ;
Lee, Choonsik .
RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2020, 59 (01) :151-160
[32]   Dose coefficients of percentile-specific computational phantoms for photon external exposures [J].
Yeon Soo Yeom ;
Haegin Han ;
Chansoo Choi ;
Bangho Shin ;
Chan Hyeong Kim ;
Choonsik Lee .
Radiation and Environmental Biophysics, 2020, 59 :151-160
[33]   Effective dose conversion coefficient for gamma ray exposure from an overhead plume [J].
Dey, Riya ;
Patni, H. K. ;
Singh, Kapil Deo ;
Kulkarni, M. S. ;
Anand, S. .
PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (15)
[34]   A Monte Carlo estimation of effective dose in chest tomosynthesis [J].
Sabol, John M. .
MEDICAL PHYSICS, 2009, 36 (12) :5480-5487
[35]   Monte Carlo calculation of the organ equivalent dose and effective dose due to immersion in a 16N beta source in air using the ICRP reference phantoms [J].
Gomez-Ros, Jose M. ;
Moraleda, Montserrat ;
Arce, Pedro ;
Bui, Duc-Ky ;
Dang, Thi-My-Linh ;
Desorgher, Laurent ;
Kim, Han Sung ;
Krstic, Dragana ;
Kuc, Michal ;
Le, Ngoc-Thiem ;
Lee, Yi-Kang ;
Nguyen, Ngoc-Quynh ;
Nikezic, Dragoslav ;
Tyminska, Katarzyna ;
Vrba, Tomas .
RADIATION MEASUREMENTS, 2021, 145
[36]   CARDIAC CATHETERIZATION: IMPACT OF FACE AND NECK SHIELDING ON NEW ESTIMATES OF EFFECTIVE DOSE [J].
von Boetticher, Heiner ;
Lachmund, Joern ;
Hoffmann, Wolfgang .
HEALTH PHYSICS, 2009, 97 (06) :622-627
[37]   BETA-RAY DOSE DISTRIBUTIONS FROM POINT SOURCES IN AN INFINITE WATER MEDIUM [J].
CROSS, WG ;
FREEDMAN, NO ;
WONG, PY .
HEALTH PHYSICS, 1992, 63 (02) :160-171
[38]   Low dose radiation therapy for COVID-19: Effective dose and estimation of cancer risk [J].
Garcia-Hernandez, Trinitat ;
Romero-Exposito, Maite ;
Sanchez-Nieto, Beatriz .
RADIOTHERAPY AND ONCOLOGY, 2020, 153 :289-295
[39]   Fluence-to-effective dose conversion coefficients from a Saudi population based phantom for monoenergetic photon beams from 10 keV to 20 MeV [J].
Ma, Andy K. ;
Hussein, Mohammed Adel ;
Altaher, Khalid Mohammed ;
Farid, Khalid Yousif ;
Amer, Mamun ;
Aldhafery, Bander Fuhaid ;
Alghamdi, Ali A. .
JOURNAL OF RADIOLOGICAL PROTECTION, 2015, 35 (01) :75-86
[40]   The difference of scoring dose to water or tissues in Monte Carlo dose calculations for low energy brachytherapy photon sources [J].
Landry, Guillaume ;
Reniers, Brigitte ;
Pignol, Jean-Philippe ;
Beaulieu, Luc ;
Verhaegen, Frank .
MEDICAL PHYSICS, 2011, 38 (03) :1526-1533