Chemometric evaluation of the band broadening in micellar electrokinetic chromatography of peptides

被引:7
|
作者
Thorsteinsdóttir, M
Westerlund, D
Andersson, G
Kaufmann, P
机构
[1] Univ Uppsala, Ctr Biomed, Fac Pharm, S-75123 Uppsala, Sweden
[2] Scotia Lipid Tekn AB, S-11384 Stockholm, Sweden
关键词
band broadening; micellar electrokinetic chromatography; chemometrics; taurodeoxycholate micelles; response surface modelling; peptides;
D O I
10.1016/S0021-9673(98)00154-X
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Very high efficiencies were obtained for enkephalin-related peptides with low distribution to anionic micelles of taurodeoxycholate (TDC), while the efficiencies decreased drastically for peptides with a strong association to the micelles. This phenomenon was evaluated by studying the influence of TDC concentration, injected plug length, applied voltage, temperature, ionic strength of the background electrolyte and composition of injected solution on the band broadening. A chemometric approach, using a fractional factorial design for the screening experiment and response surface modelling was applied to evaluate the effect of the experimental factors on the peak width of the peptides. Partial least square regression of the peak widths at different TDC concentrations revealed two different phenomena in the system. One in which electrophoretic migration in the aqueous phase dominated, giving narrow peak widths, and a second dominated by micellar solubilization, resulting in peak widths four-times broader for the peptides, probably due to slow sorption-desorption kinetics. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:191 / 201
页数:11
相关论文
共 50 条
  • [1] BAND BROADENING IN ELECTROKINETIC CHROMATOGRAPHY WITH MICELLAR SOLUTIONS AND OPEN-TUBULAR CAPILLARIES
    TERABE, S
    OTSUKA, K
    ANDO, T
    ANALYTICAL CHEMISTRY, 1989, 61 (03) : 251 - 260
  • [2] Band broadening in micellar liquid chromatography
    Lavine, BK
    Hendayana, S
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1996, 19 (01) : 101 - 123
  • [3] Micellar electrokinetic chromatography of highly hydrophobic peptides
    Idei, M
    Seprodi, J
    Gyorffy, E
    Hollósy, F
    Vadász, Z
    Mészáros, G
    Teplán, I
    Kéri, G
    ANALYTICA CHIMICA ACTA, 1998, 372 (1-2) : 273 - 279
  • [4] Band broadening arising from stepwise alterations in mobile phase composition in micellar electrokinetic chromatography
    Butehorn, U
    Pyell, U
    CHROMATOGRAPHIA, 1996, 43 (5-6) : 237 - 241
  • [5] Multivariate evaluation of the separation performance in micellar electrokinetic capillary chromatography of peptides: Optimization
    M. Thorsteinsdóttir
    D. Westerlund
    G. Andersson
    P. Kaufmann
    Chromatographia, 1998, 47 : 141 - 151
  • [6] Multivariate evaluation of the separation performance in micellar electrokinetic capillary chromatography of peptides: Optimization
    Thorsteinsdottir, M
    Westerlund, D
    Andersson, G
    Kaufmann, P
    CHROMATOGRAPHIA, 1998, 47 (3-4) : 141 - 151
  • [7] Multivariate evaluation of the separation performance in micellar electrokinetic capillary chromatography of peptides: Optimization
    Analytical Pharmaceutical Chemistry, Faculty of Pharmacy, Uppsala University Biomedical Centre, P.O Box 574, 751 23 Uppsala, Sweden
    不详
    Chromatographia, 3-4 (141-151):
  • [9] BAND BROADENING IN MICELLAR LIQUID-CHROMATOGRAPHY
    HENDAYANA, S
    LAVINE, BK
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1993, 205 : 38 - ANYL
  • [10] Multivariate evaluation of organic modifier effects on the separation performance of peptides in micellar electrokinetic chromatography
    Thorsteinsdóttir, M
    Ringbom, C
    Westerlund, D
    Andersson, G
    Kaufmann, P
    JOURNAL OF CHROMATOGRAPHY A, 1999, 831 (02) : 293 - 309