Digital coincidence counting for radionuclide standardization

被引:46
|
作者
Keightley, John
Park, Tae Soon
机构
[1] Natl Phys Lab, Teddington TW11 0LW, Middx, England
[2] Korea Res Inst Stand & Sci, Taejon 305600, South Korea
关键词
D O I
10.1088/0026-1394/44/4/S05
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The 4 pi beta-gamma coincidence method for the absolute determination of nuclear disintegration rates has for decades been successfully applied to a variety of radionuclides, via the use of suites of dedicated analogue electronic modules. The high cost of procurement and maintenance of such systems, as well as the requirement for highly experienced technicians to perform the data collection have prompted the design of more flexible data collection techniques. Recent advances in digital signal acquisition technology have facilitated the possibility of storing pulse information from multiple detector systems along with a time stamp for each recorded event, allowing various radionuclide standardization techniques ( based on the concept of 4 pi beta-gamma coincidence counting) to be implemented ' offline' via the use of dedicated software routines. This brief paper reviews the progress in the development of such ' digital coincidence counting' systems used in the field of radionuclide metrology and may be viewed as a companion article to other papers ( in this issue) on primary methods for radionuclide standardization.
引用
收藏
页码:S32 / S35
页数:4
相关论文
共 50 条
  • [41] Use of sum-peak and coincidence counting methods for activity standardization of 22Na
    de Oliveira, E. M.
    Iwahara, A.
    Poledna, R.
    da Silva, M. A. L.
    Tauhata, L.
    Delgado, J. U.
    Lopes, R. T.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 687 : 69 - 74
  • [42] STANDARDIZATION OF 125I BY PHOTON-PHOTON COINCIDENCE COUNTING AND EFFICIENCY EXTRAPOLATION.
    Schrader, H.
    Walz, K.F.
    International journal of radiation applications and instrumentation. Part A, Applied radiation and isotopes, 1987, 38 (10): : 763 - 766
  • [43] Performance demonstration of 4πβ(LS)-γ coincidence counting systemcross for standardization of radionuclides with complex decay scheme
    Kulkarni, D. B.
    Anuradha, R.
    Joseph, Leena
    Kulkarni, M. S.
    Tomar, B. S.
    APPLIED RADIATION AND ISOTOPES, 2016, 108 : 24 - 29
  • [44] Software coincidence counting
    Havelka, M
    Auerbach, P
    Sochorová, J
    APPLIED RADIATION AND ISOTOPES, 2002, 56 (1-2) : 265 - 268
  • [45] COINCIDENCE AND NON-COINCIDENCE COUNTING - REPLY
    BING, RJ
    IDEDA, S
    JOURNAL OF NUCLEAR MEDICINE, 1976, 17 (02) : 154 - 154
  • [46] A High Speed High Resolution Digital Platform for the 4πβ-γ Coincidence Counting System
    Zhang, Keli
    Song, Kezhu
    Yang, Junfeng
    Cao, Ping
    Wang, Haomi
    2012 18TH IEEE-NPSS REAL TIME CONFERENCE (RT), 2012,
  • [47] Standardization of 139Ce by the liquid scintillation counting using the triple to double coincidence ratio method
    Radioisotope Cent, Otwock-Swierk, Poland
    Appl Radiat Isot, 9-11 (1035-1040):
  • [48] THE ENHANCED TRIPLE TO DOUBLE COINCIDENCE RATIO (ETDCR) METHOD FOR STANDARDIZATION OF RADIONUCLIDES BY LIQUID SCINTILLATION-COUNTING
    BRODA, R
    POCHWALSKI, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 312 (1-2): : 85 - 89
  • [49] STANDARDIZATION OF SE-75 BY 4-PI(E, X)-GAMMA COINCIDENCE COUNTING METHOD
    PARK, TS
    KIM, IS
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 312 (1-2): : 67 - 70
  • [50] Standardization of 139Ce by the liquid scintillation counting using the triple to double coincidence ratio method
    Broda, R
    Peron, MN
    Cassette, P
    Terlikowska, T
    Hainos, D
    APPLIED RADIATION AND ISOTOPES, 1998, 49 (9-11) : 1035 - 1040