Digital coincidence counting for radionuclide standardization

被引:46
|
作者
Keightley, John
Park, Tae Soon
机构
[1] Natl Phys Lab, Teddington TW11 0LW, Middx, England
[2] Korea Res Inst Stand & Sci, Taejon 305600, South Korea
关键词
D O I
10.1088/0026-1394/44/4/S05
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The 4 pi beta-gamma coincidence method for the absolute determination of nuclear disintegration rates has for decades been successfully applied to a variety of radionuclides, via the use of suites of dedicated analogue electronic modules. The high cost of procurement and maintenance of such systems, as well as the requirement for highly experienced technicians to perform the data collection have prompted the design of more flexible data collection techniques. Recent advances in digital signal acquisition technology have facilitated the possibility of storing pulse information from multiple detector systems along with a time stamp for each recorded event, allowing various radionuclide standardization techniques ( based on the concept of 4 pi beta-gamma coincidence counting) to be implemented ' offline' via the use of dedicated software routines. This brief paper reviews the progress in the development of such ' digital coincidence counting' systems used in the field of radionuclide metrology and may be viewed as a companion article to other papers ( in this issue) on primary methods for radionuclide standardization.
引用
收藏
页码:S32 / S35
页数:4
相关论文
共 50 条
  • [21] Standardization of 110mAg by liquid scintillation and 4πβ-γ coincidence counting
    García-Toraño, E
    Roteta, M
    Barquero, LR
    APPLIED RADIATION AND ISOTOPES, 2000, 52 (03) : 637 - 641
  • [22] STANDARDIZATION OF C-14 BY LIQUID-SCINTILLATION COINCIDENCE COUNTING
    WU, XZ
    SONG, L
    WANG, ZY
    YANG, YD
    WANG, C
    APPLIED RADIATION AND ISOTOPES, 1987, 38 (10) : 891 - 897
  • [23] STANDARDIZATION OF IODINE-129 BY BETA-PHOTON COINCIDENCE COUNTING
    MANN, WB
    HUTCHINSON, JMR
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1976, 27 (03): : 187 - 188
  • [24] Digital coincidence counting (DCC) and its use in the corrections for out-of-channel gamma events in 4πβ-γ coincidence counting
    Keightley, JD
    Watt, GC
    APPLIED RADIATION AND ISOTOPES, 2002, 56 (1-2) : 205 - 210
  • [25] STANDARDIZATION OF 14C BY LIQUID-SCINTILLATION COINCIDENCE COUNTING.
    Wu, X.Z.
    Song, L.
    Wang, Z.Y.
    Yang, Y.D.
    Wang, C.
    International journal of radiation applications and instrumentation. Part A, Applied radiation and isotopes, 1987, 38 (10): : 891 - 897
  • [26] ABSOLUTE STANDARDIZATION OF 195AU BY BETA-GAMA COINCIDENCE COUNTING
    ADAMS, RJ
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1969, 20 (11): : 808 - &
  • [27] Standardization of 75Se by 4π(c, x)-γ coincidence counting method
    Park, T.S.
    Kim, I.S.
    Nuclear Instruments & Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1992, 312 (1-2):
  • [28] Development of a movable 4πβ(LS)-γ coincidence counting system for activity standardization of β-γ emitters
    Lee, J. M.
    Agung, A.
    Hwang, S. H.
    Lee, K. B.
    Hwang, H. Y.
    APPLIED RADIATION AND ISOTOPES, 2021, 174
  • [29] A DEVICE FOR AUTOMATIC DIGITAL DEADTIME CORRECTION OF COUNTING LOSSES OF SINGLE AND COINCIDENCE COUNTING RATES
    SEUFERT, H
    NUCLEAR INSTRUMENTS & METHODS, 1966, 44 (02): : 335 - &
  • [30] Application of digital sampling techniques for 4πβ(LS)-γ coincidence counting
    Lee, K. B.
    Lee, Jong Man
    Park, Tae Soon
    Oh, Pil Jei
    Lee, Sang Han
    Lee, Min Kie
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 626 : 72 - 76