Digital coincidence counting for radionuclide standardization

被引:46
|
作者
Keightley, John
Park, Tae Soon
机构
[1] Natl Phys Lab, Teddington TW11 0LW, Middx, England
[2] Korea Res Inst Stand & Sci, Taejon 305600, South Korea
关键词
D O I
10.1088/0026-1394/44/4/S05
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The 4 pi beta-gamma coincidence method for the absolute determination of nuclear disintegration rates has for decades been successfully applied to a variety of radionuclides, via the use of suites of dedicated analogue electronic modules. The high cost of procurement and maintenance of such systems, as well as the requirement for highly experienced technicians to perform the data collection have prompted the design of more flexible data collection techniques. Recent advances in digital signal acquisition technology have facilitated the possibility of storing pulse information from multiple detector systems along with a time stamp for each recorded event, allowing various radionuclide standardization techniques ( based on the concept of 4 pi beta-gamma coincidence counting) to be implemented ' offline' via the use of dedicated software routines. This brief paper reviews the progress in the development of such ' digital coincidence counting' systems used in the field of radionuclide metrology and may be viewed as a companion article to other papers ( in this issue) on primary methods for radionuclide standardization.
引用
收藏
页码:S32 / S35
页数:4
相关论文
共 50 条
  • [1] Data Analysis Software for Radionuclide Standardization with a Digital Coincidence Counting System
    Brancaccio, Franco
    Dias, Mauro da Silva
    Koskinas, Marina Fallone
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [2] Data analysis software package for radionuclide standardization with a digital coincidence counting system
    Brancaccio, F.
    Dias, M. S.
    Koskinas, M. F.
    Moreira, D. S.
    de Toledo, F.
    APPLIED RADIATION AND ISOTOPES, 2020, 155
  • [3] Device for Measuring Radionuclide Activity by Digital Coincidence Counting
    Kuvykin I.V.
    Tsuriev S.M.-S.
    Measurement Techniques, 2018, 61 (3) : 303 - 307
  • [4] Recent Advances in Digital Coincidence Counting for Radionuclide Metrology
    Keightley, John
    Bobin, Christophe
    Bouchard, Jacques
    Capogni, Marco
    Loreti, Stefano
    Roteta, Miguel
    2013 3RD INTERNATIONAL CONFERENCE ON ADVANCEMENTS IN NUCLEAR INSTRUMENTATION, MEASUREMENT METHODS AND THEIR APPLICATIONS (ANIMMA), 2013,
  • [5] Standardization of 18F by digital coincidence counting
    Kim, Eun-Joo
    Park, Tae Soon
    Lee, Jong Man
    Hahm, Don Shik
    Lee, K. B.
    APPLIED RADIATION AND ISOTOPES, 2012, 70 (09) : 2103 - 2106
  • [6] Standardization of radionuclide by β(LS)-γ coincidence counting using the geometry-efficiency variation method
    Hwang, Han-Yull
    Sung, Ki Suk
    Lee, K. B.
    Lee, Jong Man
    Park, Tae Soon
    APPLIED RADIATION AND ISOTOPES, 2006, 64 (10-11) : 1119 - 1123
  • [7] RADIONUCLIDE STANDARDIZATION BY CHERENKOV COUNTING
    CARLES, AG
    MALONDA, AG
    APPLIED RADIATION AND ISOTOPES, 1995, 46 (08) : 799 - 803
  • [8] Digital coincidence counting with 4πβ(PPC)-γ for the standardization of 60Co
    Han, Minji
    Hwang, Sanghoon
    Agusbudiman, Agung
    Lee, J. M.
    Lee, K. B.
    Kim, B. C.
    Heo, D. H.
    Kim, T. H.
    APPLIED RADIATION AND ISOTOPES, 2024, 205
  • [9] Standardization of 241Am by digital coincidence counting, liquid scintillation counting and defined solid angle counting
    Balpardo, C.
    Capoulat, M. E.
    Rodrigues, D.
    Arenillas, P.
    APPLIED RADIATION AND ISOTOPES, 2010, 68 (7-8) : 1358 - 1361
  • [10] Digital coincidence counting
    Buckman, SM
    Ius, D
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 369 (2-3): : 368 - 374