Direct measurement of Cu(II)aq in seawater at pH 8 with the jalpaite ion-selective electrode

被引:42
|
作者
Zirino, A
VanderWeele, DA
Belli, SL
DeMarco, R
Mackey, DJ
机构
[1] SPAWAR Syst Ctr, San Diego, CA 92152 USA
[2] Curtin Univ Technol, Sch Appl Chem, Perth, WA 6001, Australia
[3] CSIRO, Div Oceanog, Hobart, Tas 7001, Australia
关键词
measurement; seawater; copper; ion-selective electrode;
D O I
10.1016/S0304-4203(97)00108-4
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The variability of measurement of the pCu of seawater at pH 8 was studied using up to 5 similar Orion 90-24, jalpaite-based electrodes. Large variability (ca. 1 pCu unit) among the values yielded by the individual electrodes was observed when the electrodes were stored in artificial seawater and exposed to light including sunlight This variability is in agreement with mechanisms proposed previously. The variability among the electrodes was reduced to about +/-0.2 pCu units when the electrodes were stored in sacrificial EN seawater solution and shielded from light. Eight measurements of San Diego Bay seawater made with an individual electrode yielded pCu = 12.23 +/-:0.06 (1 sigma) regardless of the order in which the electrode was calibrated with standard buffer solutions. This degree of precision makes it possible to follow the small, time-dependent changes in the pCu of seawater. The effects of electrode rotation and the adsorption or desorption of organic matter on the electrode are presented and discussed. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:173 / 184
页数:12
相关论文
共 50 条
  • [41] DIRECT ION-SELECTIVE ELECTRODE DETERMINATION OF MICROMOLAR BORON AS TETRAFLUOROBORATE
    GULENS, J
    LEESON, PK
    ANALYTICAL CHEMISTRY, 1980, 52 (13) : 2235 - 2237
  • [42] DIRECT DETERMINATION OF BENZYLNITRILES USING THE CYANIDE ION-SELECTIVE ELECTRODE
    HASSAN, SSM
    MARI, MA
    MIKROCHIMICA ACTA, 1986, 1 (3-4) : 201 - 205
  • [43] DIRECT ION-SELECTIVE ELECTRODE METHOD IS USEFUL IN DIAGNOSIS OF PSEUDOHYPONATREMIA
    Dhatt, Gurjit
    Talor, Zvi
    Kazory, Amir
    JOURNAL OF EMERGENCY MEDICINE, 2012, 43 (02): : 348 - 349
  • [44] Calibration of the Hg chalcogenide glass membrane ion-selective electrode in seawater media
    De Marco, R
    Shackleton, J
    TALANTA, 1999, 49 (02) : 385 - 391
  • [45] COPPER(I) ACTIVITY OF THE COPPER(II) ION-SELECTIVE ELECTRODE
    STUNZI, H
    TALANTA, 1982, 29 (01) : 75 - 76
  • [46] COATED WIRE ION-SELECTIVE ELECTRODE FOR DETERMINATION OF ZINC(II)
    CATTRALL, RW
    PUI, CP
    ANALYTICA CHIMICA ACTA, 1976, 87 (02) : 419 - 427
  • [47] PREPARATION AND ANALYTICAL APPLICATIONS OF A COPPER(II) ION-SELECTIVE ELECTRODE
    DELRIO, MIG
    ARRIBAS, MCB
    BATANERO, PS
    ANALUSIS, 1983, 11 (03) : 131 - 135
  • [48] Cd(II)-ion-selective electrode based on chalcogenide glasses
    Vassilev, V.
    Radonova, M.
    Boycheva, S.
    JOURNAL OF NON-CRYSTALLINE SOLIDS, 2009, 355 (48-49) : 2365 - 2369
  • [49] Polymeric membrane ion-selective electrode based on potential-modulated ion transfer: ultrasensitive measurement of oceanic pH
    Liu, Lu
    Liu, Yuanxin
    Jiang, Tianjia
    Liang, Rongning
    Qin, Wei
    CHEMICAL COMMUNICATIONS, 2024, 60 (91) : 13404 - 13407
  • [50] COUPLED ION-SELECTIVE ELECTRODE MEASUREMENT OF AQUEOUS CARBONATE AND BICARBONATE ION ACTIVITIES
    PIGOTT, JD
    ANALYTICAL CHEMISTRY, 1989, 61 (06) : 638 - 640