In vivo solid phase microextraction sampling of human saliva for non-invasive and on-site monitoring

被引:88
作者
Bessonneau, Vincent [1 ]
Boyaci, Ezel [1 ]
Maciazek-Jurczyk, Malgorzata [1 ]
Pawliszyn, Janusz [1 ]
机构
[1] Univ Waterloo, Dept Chem, Waterloo, ON N2L 3G1, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Saliva; In vivo sampling; Solid-phase microextraction; Doping substances; Steroids; CHROMATOGRAPHY-MASS SPECTROMETRY; VOLATILE ORGANIC-COMPOUNDS; ALTERNATIVE SPECIMENS; HORMONE MEASUREMENT; METABOLOME; LC/MS/MS; CORTISOL; TOOL; LC;
D O I
10.1016/j.aca.2014.11.029
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
On-site sample preparation is an analytical approach based on direct sampling from the system under investigation. It has the advantage of combining sampling and sample preparation into a single step, thus generally is fast, minimizes the potential sources of error and eliminates the risks for analytes instability. For such analysis solid phase microextraction in thin film geometry (TF-SPME) can provide robust and convenient in vivo sampling, offering in the same time faster analysis and higher extraction recovery (i.e., better sensitivity) due to large surface to volume ratio. In this study, TF-SPME in coated blade and membrane formats with a single extraction phase were used for in vivo and ex vivo saliva extraction and separation by LC and GC, respectively. Due to applicability for wide range of polarity of analytes as well as thermal and solvent stability during the desorption, hydrophilic lipophilic balanced particles (HLB) were chosen as extraction phase and used for fast (5 min) in vivo and ex vivo sampling. The results of metabolomic profiling of the saliva are indicating that even 5 min in vivo sampling using TF-SPME followed by GC and LC analyses provides complementary coverage of wide range of analytes with different physical and chemical properties. To demonstrate the applicability of the method for doping analyses, the SPME-LC-MS/MS method was validated for simultaneous quantification of 49 prohibited substances with limit of quantification (LOQ) ranging between 0.004 and 0.98 ng mL(-1). Moreover, the method was also validated and successfully applied for determination of endogenous steroids in saliva where the concentrations of the analytes are substantially low. The developed assay offers fast and reliable multiresidue analysis of saliva as an attractive alternative to the standard analysis methods. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:35 / 45
页数:11
相关论文
共 27 条
  • [1] An investigation of volatile organic compounds from the saliva of healthy individuals using headspace-trap/GC-MS
    AL-Kateb, Huda
    Costello, Benjamin de Lacy
    Ratcliffe, Norman
    [J]. JOURNAL OF BREATH RESEARCH, 2013, 7 (03)
  • [2] Bessonneau V, 2013, BIOANALYSIS, V5, P783, DOI [10.4155/BIO.13.35, 10.4155/bio.13.35]
  • [3] SPME - Quo vadis?
    Bojko, Barbara
    Cudjoe, Erasmus
    Gomez-Rios, German A.
    Gorynski, Krzysztof
    Jiang, Ruifen
    Reyes-Garces, Nathaly
    Risticevic, Sanja
    Silva, Erica A. S.
    Togunde, Oluranti
    Vuckovic, Dajana
    Pawliszyn, Janusz
    [J]. ANALYTICA CHIMICA ACTA, 2012, 750 : 132 - 151
  • [4] Introduction of solid-phase microextraction as a high-throughput sample preparation tool in laboratory analysis of prohibited substances
    Boyaci, Ezel
    Gorynski, Krzysztof
    Rodriguez-Lafuente, Angel
    Bojko, Barbara
    Pawliszyn, Janusz
    [J]. ANALYTICA CHIMICA ACTA, 2014, 809 : 69 - 81
  • [5] Applicability of emanating volatile organic compounds from various forensic specimens for individual differentiation
    Brown, Jessica S.
    Prada, Paola A.
    Curran, Allison M.
    Furton, Kenneth G.
    [J]. FORENSIC SCIENCE INTERNATIONAL, 2013, 226 (1-3) : 173 - 182
  • [6] Kinetics and the on-site application of standards in a solid-phase microextration fiber
    Chen, Y
    Pawliszyn, J
    [J]. ANALYTICAL CHEMISTRY, 2004, 76 (19) : 5807 - 5815
  • [7] de Almeida Patricia Del Vigna, 2008, J Contemp Dent Pract, V9, P72
  • [8] Fast Analytical Methodology Based on Mass Spectrometry for the Determination of Volatile Biomarkers in Saliva
    del Nogal Sanchez, Miguel
    Hernandez Garcia, Elena
    Perez Pavon, Jose Luis
    Moreno Cordero, Bernardo
    [J]. ANALYTICAL CHEMISTRY, 2012, 84 (01) : 379 - 385
  • [9] The role of alternative specimens in toxicological analysis
    Gallardo, E.
    Queiroz, J. A.
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2008, 22 (08) : 795 - 821
  • [10] Salivary Sex Hormone Measurement in a National, Population-Based Study of Older Adults
    Gavrilova, Natalia
    Lindau, Stacy Tessler
    [J]. JOURNALS OF GERONTOLOGY SERIES B-PSYCHOLOGICAL SCIENCES AND SOCIAL SCIENCES, 2009, 64 : I94 - I105