Three-dimensional measurement of the course of the radial nerve at the posterior humeral shaft: An in vivo anatomical study

被引:4
作者
Park, Ji-Kang [1 ]
Choi, Seung-Myung [1 ,2 ,3 ]
Kang, Sang-Woo [1 ]
Kim, Kook-Jong [1 ]
Min, Kyoung-Tae [1 ]
机构
[1] Chungbuk Natl Univ Hosp, Sch Med, Dept Orthpaed Surg, Cheongju, South Korea
[2] Konkuk Univ, Sch Med, Dept Orthpaed Surg, Chungju Hosp, 82 Gugwon Daero, Chungju 27376, South Korea
[3] Chungbuk Natl Univ, Grad Sch Med, Dept Orthoped Surg, Cheongju, South Korea
关键词
anatomy; humerus; radial nerve; three-dimensional reconstruction; COMPUTED-TOMOGRAPHY; SAFE ZONE; PALSY; ELBOW; PIN; SEGMENTATION;
D O I
10.1177/2309499020930828
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: Iatrogenic radial nerve injury caused by surgical exposure of the humerus is a serious complication. We aimed to describe the course of the radial nerve at the posterior humeral shaft using a three-dimensional (3D) reconstruction technique by utilizing computed tomography (CT) images of living subjects. We hypothesized that the course of the radial nerve in the posterior aspect of the humeral shaft would be reliably established using this technique and the measurements would have satisfactory intraobserver/interobserver reliabilities. Methods: This in vivo anatomical study utilized 652 upper extremity CT angiography images from 326 patients. A 3D modeling of the humerus and radial nerve was performed. We evaluated the segment of the radial nerve that lays directly on the posterior aspect of the humeral shaft and measured its proximal point, mid, and distal points. The shortest distances from the olecranon fossa to these points were defined as R1, R2, and R3, respectively. The relationships between these parameters and humeral length (HL) and transcondylar length (TL) were evaluated, and the intraobserver/interobserver reliabilities of these parameters were measured. Results: The HL was 293.6 mm, and TL was 58.64 mm on average. The R1 measured 159.2 (range 127.1-198.2) mm, R2 was 136.6 (105.7-182.5), and R3 was 112.8 (76.8-150.0) mm on average (p< .001). The intraobserver/interobserver reliabilities ranged from 0.90 to 0.98. Conclusion: The course of the radial nerve at the posterior aspect of the humeral shaft can be reliably established using the 3D reconstruction technique, and all measurements had excellent intraobserver/interobserver reliability.
引用
收藏
页数:8
相关论文
共 50 条
[21]   The human endosalpinx: anatomical three-dimensional study and reconstruction using confocal microtomography [J].
Castro, Pedro Teixeira ;
Aranda, Osvaldo Luiz ;
Pinho Matos, Ana Paula ;
Marchiori, Edson ;
Bittencourt de Araujo, Luiz Felipe ;
Lopes Alves, Haimon Diniz ;
Machado, Alessandra Silveira ;
Lopes, Ricardo Tadeu ;
Werner, Heron ;
Araujo Junior, Edward .
POLISH JOURNAL OF RADIOLOGY, 2019, 84 :E281-E288
[22]   Three-dimensional motion patterns of the carpel bones:: an in vivo study using three-dimensional computed tomography and clinical applications [J].
Feipel, V ;
Rooze, M .
SURGICAL AND RADIOLOGIC ANATOMY, 1999, 21 (02) :125-131
[23]   Three-dimensional motion patterns of the carpal bones: an in vivo study using three-dimensional computed tomography and clinical applications [J].
V. Feipel ;
M. Rooze .
Surgical and Radiologic Anatomy, 1999, 21 :125-131
[24]   Three-dimensional anatomical model of the facial nerve in 100 parotid tumours: improved planning and personalised surgery [J].
McGurk, M. ;
Sassoon, I. ;
Morley, S. .
BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2025, 63 (06) :455-461
[25]   Anatomical consideration for safe pericardiocentesis assessed by three-dimensional computed tomography: Should an anterior or posterior approach be used? [J].
Teranishi, Jin ;
Okajima, Katsunori ;
Kiuchi, Kunihiko ;
Shimane, Akira ;
Fukuzawa, Koji ;
Kanda, Gaku ;
Yokoi, Kiminobu ;
Yamada, Shinichiro ;
Taniguchi, Yasuyo ;
Yasaka, Yoshinori ;
Kawai, Hiroya .
JOURNAL OF ARRHYTHMIA, 2014, 30 (06) :491-495
[26]   A comprehensive framework of the right posterior section for tailored anatomical liver resection based on three-dimensional simulation system [J].
Zhang, Feihong ;
Xu, Zhenggang ;
Sun, Dongwei ;
Jiao, Chenyu ;
Ji, Guwei ;
Wang, Ke .
ANNALS OF TRANSLATIONAL MEDICINE, 2022, 10 (16)
[27]   Measurement and comparison of tibial posterior slope angle in different methods based on three-dimensional reconstruction [J].
Zhang, Yang ;
Wang, Jian ;
Xiao, Jun ;
Zhao, Liang ;
Li, Zhi-han ;
Yan, Ge ;
Shi, Zhan-jun .
KNEE, 2014, 21 (03) :694-698
[28]   The relationship between the midpoints connecting the tibial attachments of the anterior and posterior cruciate ligaments and the transepicondylar axis: In vivo three-dimensional measurement in the Chinese population [J].
Yang, Guang ;
Wang, Zhuo ;
Wen, Xiaoyu ;
Jiang, Zhengang ;
Qi, Xin ;
Yang, Chen .
KNEE, 2016, 23 (05) :777-784
[29]   Three-Dimensional Study of the Facial Canal Using Microcomputed Tomography for Improved Anatomical Comprehension [J].
Shin, Kang-Jae ;
Gil, Young-Chun ;
Lee, Ju-Young ;
Kim, Jeong-Nam ;
Song, Wu-Chul ;
Koh, Ki-Seok .
ANATOMICAL RECORD-ADVANCES IN INTEGRATIVE ANATOMY AND EVOLUTIONARY BIOLOGY, 2014, 297 (10) :1808-1816
[30]   Three-dimensional thoracic modeling for an anatomical compatibility study of the implantable total artificial heart [J].
Zhang, B ;
Masuzawa, T ;
Tatsumi, E ;
Taenaka, Y ;
Uyama, C ;
Takano, H ;
Takamiya, M .
ARTIFICIAL ORGANS, 1999, 23 (03) :229-234