Copper Nanoparticles with Copper Hexacyanoferrate and Poly(3,4-ethylenedioxythiophene) Hybrid Film Modified Electrode for Hydrogen Peroxide Detection

被引:0
|
作者
Tsai, Tsung-Hsuan [1 ]
Chen, Tse-Wei [1 ,2 ]
Chen, Shen-Ming [1 ]
机构
[1] Natl Taipei Univ Technol, Electroanal & Bioelectrochem Lab, Dept Chem Engn & Biotechnol, Taipei 106, Taiwan
[2] Fu Jen Catholic Univ, Dept Chem, New Taipei City 24205, Taiwan
来源
INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE | 2011年 / 6卷 / 10期
关键词
Copper nanoparticles; Copper Hexacyanoferrate; PEDOT; Electrocatalysis; Hydrogen Peroxide; Modified Electrodes; GLASSY-CARBON ELECTRODE; ELECTROCATALYTIC PROPERTIES; ASCORBIC-ACID; ELECTROCHEMICAL PREPARATION; NICKEL HEXACYANOFERRATE; COBALT; HYDROXYLAMINE; OXIDATION; BEHAVIOR; SENSOR;
D O I
暂无
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
An electroactive polynuclear hybrid films of copper nanoparticles with copper hexacyanoferrate (copper NPs-CuHCF) have been deposited on PEDOT electrode surfaces from KNO3 solution (pH 5.6) containing CuCl2 and K-3[Fe(CN)(6)] by multiple scan cyclic voltammetry. The films were characterized using field emission scanning electron microscopy and energy dispersive spectroscopy. The advantages of these films were demonstrated for the detection of hydrogen peroxide (H2O2) using cyclic voltammetry and amperometric techniques. The electrocatalytic reduction of H2O2 at different electrode surfaces, such as the bare GCE, the CuHCF/PEDOT/GCE, and the copper NPs/PEDOT/GCE modified electrodes, was determined in KNO3 solution (pH 5.6). The H2O2 electrochemical sensor exhibited a linear response range (from 1 x 10(-6) to 5.4 x 10(-4) M, R-2 = 0.9975, lowest detection limit (1 x 10(-7) M) and fast response time (3 s) for H2O2 determination. In addition, the copper NPs-CuHCF/PEDOT/GCE was advantageous in terms of its simple preparation, specificity, stability and reproducibility.
引用
收藏
页码:4628 / 4637
页数:10
相关论文
共 50 条
  • [1] Nickel, copper and manganese hexacyanoferrate with poly(3,4-ethylenedioxythiophene) hybrid film modified electrode for selectively determination of ascorbic acid
    Tsai, Tsung-Hsuan
    Chen, Tse-Wei
    Chen, Shen-Ming
    Sarawathi, Ramiah
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2012, 48 (03) : 291 - 301
  • [2] Selective Electroanalysis of Ascorbic Acid Using a Nickel Hexacyanoferrate and Poly(3,4-ethylenedioxythiophene) Hybrid Film Modified Electrode
    Tsai, Tsung-Hsuan
    Chen, Tse-Wei
    Chen, Shen-Ming
    ELECTROANALYSIS, 2010, 22 (14) : 1655 - 1662
  • [3] Nickel, copper and manganese hexacyanoferrate with poly(3,4-ethylenedioxythiophene) hybrid film modified electrode for selectively determination of ascorbic acid
    Tsung-Hsuan Tsai
    Tse-Wei Chen
    Shen-Ming Chen
    Ramiah Sarawathi
    Russian Journal of Electrochemistry, 2012, 48 : 291 - 301
  • [4] Manganese Hexacyanoferrate with Poly(3,4-ethylenedioxythiophene) Hybrid Film Modified Electrode for the Determination of Catechin and Melatonin
    Tsai, Tsung-Hsuan
    Huang, Yun-Chin
    Chen, Shen-Ming
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2011, 6 (08): : 3238 - 3253
  • [5] Farication of Silver Hexacyanoferrate and Functionlized MWCNT with Poly(3,4-ethylenedioxythiophene) Hybrid Film Modified Electrode for Selectively Determination of Ascorbic Acid And Hydrazine
    Yang, Cheng-Yu
    Hung, Yu-Tsung
    Chen, Shen-Ming
    Tsai, Tsung-Hsuan
    Lou, Bih-Show
    Liu, Xiaoheng
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2015, 10 (02): : 1128 - 1135
  • [6] Preparation and characterisation of poly(3,4-ethylenedioxythiophene) and poly(3,4-ethylenedioxythiophene)/poly(neutral red) modified carbon film electrodes, and application as sensors for hydrogen peroxide
    Ricardo Goncalves, A.
    Emilia Ghica, M.
    Brett, Christopher M. A.
    ELECTROCHIMICA ACTA, 2011, 56 (10) : 3685 - 3692
  • [7] Electrochemistry and detection of dopamine at a poly(3,4-ethylenedioxythiophene) electrode modified with ferrocene and cobaltocene
    Atta, Nada F.
    Galal, Ahmed
    Ali, Shimaa M.
    Hassan, Samar H.
    IONICS, 2015, 21 (08) : 2371 - 2382
  • [8] Detection of nitrite using poly(3,4-ethylenedioxythiophene) modified SPCEs
    Lin, Chia-Yu
    Vasantha, V. S.
    Ho, Kuo-Chuan
    SENSORS AND ACTUATORS B-CHEMICAL, 2009, 140 (01): : 51 - 57
  • [9] Selective electrochemical determination of dopamine, using a poly(3,4-ethylenedioxythiophene)/polydopamine hybrid film modified electrode
    Salgado, R.
    del Rio, R.
    del Valle, M. A.
    Armijo, F.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2013, 704 : 130 - 136
  • [10] Electrocatalytic Production of Hydrogen Peroxide with Poly(3,4-ethylenedioxythiophene) Electrodes
    Mitraka, Evangelia
    Gryszel, Maciej
    Vagin, Mikhail
    Jafari, Mohammad Javad
    Singh, Amritpal
    Warczak, Magdalena
    Mitrakas, Manassis
    Berggren, Magnus
    Ederth, Thomas
    Zozoulenko, Igor
    Crispin, Xavier
    Glowacki, Eric Daniel
    ADVANCED SUSTAINABLE SYSTEMS, 2019, 3 (02):