The current design and operation of air-cooled condensers can cause a significant decrease in chiller performance under part load conditions. This paper demonstrates optimal condenser fan control to improve the coefficient of performance (COP) of air-cooled chillers. This control involves identifying the optimum set point of condensing temperature with the optimized power relationships of the compressors and condenser fans and enhancing the airflow and heat transfer area of the condensers. An example application of this control for an air-cooled centrifugal chiller indicated that the COP could increase by 11.4-237.2%, depending on the operating conditions. Such the increase of the COP results in a reduction of up to 14.1 kWh/m(2), or 27.3% in the annual electricity consumption per unit A/C floor area of chillers, given that the chillers serve an office building requiring an annual cooling energy per unit A/C floor area of 173.3 kWh/m(2). The simulation results of this study will give HVAC engineers a better understanding of how to optimize the design and operation of air-cooled chillers. (C) 2007 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:942 / 953
页数:12
相关论文
共 50 条
  • [1] Part load performance of air-cooled centrifugal chillers with variable speed condenser fan control
    Yu, F. W.
    Chan, K. T.
    BUILDING AND ENVIRONMENT, 2007, 42 (11) : 3816 - 3829
  • [2] Optimum condenser fan staging for air-cooled chillers
    Yu, FW
    Chan, KT
    APPLIED THERMAL ENGINEERING, 2005, 25 (14-15) : 2204 - 2218
  • [3] Improved condenser design and condenser-fan operation for air-cooled chillers
    Yu, FW
    Chan, KT
    APPLIED ENERGY, 2006, 83 (06) : 628 - 648
  • [4] Modelling of a condenser-fan control for an air-cooled centrifugal chiller
    Yu, F. W.
    Chan, K. T.
    APPLIED ENERGY, 2007, 84 (11) : 1117 - 1135
  • [5] Energy performance of air-cooled chillers with sprayed water on condenser
    Lu, Jian
    Ren, Shengfeng
    Yang, Junlan
    Chang, Ru
    Shen, Zheng
    Yang, Hongxing
    FIRST INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT, PROCEEDINGS VOLS 1-3, 2008, : 355 - 362
  • [6] Optimizing Design of Direct Air-cooled Condenser
    Wang, Xuedong
    Zheng, Yanjuan
    Luan, Tao
    PROGRESS IN POWER AND ELECTRICAL ENGINEERING, PTS 1 AND 2, 2012, 354-355 : 406 - +
  • [7] A STUDY ON AIR-COOLED CHILLERS WITH EVAPORATIVELY COOLED CONDENSER FOR 3 TYPES OF CLIMATE
    Kocak Soylu, Sezgi
    Atmaca, Ibrahim
    ISI BILIMI VE TEKNIGI DERGISI-JOURNAL OF THERMAL SCIENCE AND TECHNOLOGY, 2016, 36 (01) : 1 - 8
  • [8] Air-cooled condenser
    Phogat, S.S.
    Journal of the Institution of Engineers (India): Mechanical Engineering Division, 1988, 68 pt 6 : 191 - 195
  • [9] Contributors to increased fan inlet temperature at an air-cooled steam condenser
    Owen, Michael
    Kroeger, Detlev G.
    APPLIED THERMAL ENGINEERING, 2013, 50 (01) : 1149 - 1156
  • [10] Uniformity Index as a Universal Air-Cooled Condenser Fan Performance Metric
    Marincowitz, Fredrik
    Owen, Michael
    Muiyser, Jacques
    Holkers, Peter
    INTERNATIONAL JOURNAL OF TURBOMACHINERY PROPULSION AND POWER, 2022, 7 (04)