Diagnostic of Fusion Neutrons on EAST Tokamak Using 4H-SiC Detector

被引:9
作者
Hong, B. [1 ]
Zhong, G. Q. [2 ]
Hu, L. Q. [2 ]
Zhang, R. X. [2 ]
Zhou, R. J. [2 ]
Li, K. [2 ]
Huang, L. S. [2 ]
Chen, W. K. [2 ]
机构
[1] Comprehens Natl Sci Ctr, Inst Energy, Hefei 230031, Anhui, Peoples R China
[2] Chinese Acad Sci, Inst Plasma Phys, Hefei Inst Phys Sci, Hefei 230031, Anhui, Peoples R China
关键词
Neutrons; Detectors; Plasmas; Tokamak devices; Temperature measurement; Polyethylene; Silicon carbide; 4H-SiC detector; fusion neutron; neutron diagnostics; tokamak; DIAMOND;
D O I
10.1109/TNS.2022.3146180
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Due to significant radiation hardness, thermal properties, low sensitivity to gamma rays, and fast response, the 4H-SiC detector exhibits promising properties in measuring the neutron production in the high-power fusion devices. To demonstrate the potential value of the 4H-SiC detectors as a neutron flux monitor and a neutron spectrometer on experimentally advanced superconducting tokamak (EAST) during the 2021 EAST deuterium-deuterium plasma experimental campaigns, the 4H-SiC detector covered with a 25-mu m-thick (LiF)-Li-6 film 95% enriched in Li-6 and the 4H-SiC detector covered with a 1.5-mm-thick polyethylene layer were installed on a viewport located at the mid-plane of port F outside the EAST vacuum vessel and operated continuously during the whole experimental campaign with the goal to measure both the total and the time-dependent neutron emission from the plasma. The results are compared with those obtained with detectors routinely working at EAST (U-235 Fission Chambers). Despite their small active volumes, the 4H-SiC detectors were able to measure the total and the time-dependent neutron emission with good reliability and stability. The results of this work not only demonstrated the satisfactory performance of the 4H-SiC detector in the harsh environment of a mixed neutron-gamma high-radiation field and strong electromagnetic field, but also its applicability as a neutron spectrometer and a neutron flux monitor for fusion deuterium-plasma experiments.
引用
收藏
页码:639 / 644
页数:6
相关论文
共 13 条
[1]   Development of single crystal diamond neutron detectors and test at JET tokamak [J].
Angelone, M. ;
Lattanzi, D. ;
Pillon, M. ;
Marinelli, M. ;
Milani, E. ;
Tucciarone, A. ;
Verona-Rinati, G. ;
Popovichev, S. ;
Montereali, R. M. ;
Vincenti, M. A. ;
Murari, A. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 595 (03) :616-622
[2]   A diamond based neutron spectrometer for diagnostics of deuterium-tritium fusion plasmas [J].
Cazzaniga, C. ;
Nocente, M. ;
Rebai, M. ;
Tardocchi, M. ;
Calvani, P. ;
Croci, G. ;
Giacomelli, L. ;
Girolami, M. ;
Griesmayer, E. ;
Grosso, G. ;
Pillon, M. ;
Trucchi, D. M. ;
Gorini, G. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (11)
[3]   Fast neutron detection with silicon carbide semiconductor radiation detectors [J].
Flammang, Robert W. ;
Seidel, John G. ;
Ruddy, Frank H. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 579 (01) :177-179
[4]   Neutron Detector Needs for ITER [J].
Krasilnikov, V. ;
Bertalot, L. ;
Barnsley, R. ;
Walsh, M. .
FUSION SCIENCE AND TECHNOLOGY, 2017, 71 (02) :196-200
[5]   The performance of 4H-SiC detector at high temperature after gamma irradiation [J].
Li, Zheng ;
Wu, Jian ;
Wu, Kunlin ;
Fan, Yikui ;
Bai, Zhongxiong ;
Jiang, Yong ;
Yin, Yanpeng ;
Xie, Qilin ;
Lei, Jiarong .
RADIATION PHYSICS AND CHEMISTRY, 2019, 162 :153-156
[6]   Radiation Resistance of Silicon Carbide Schottky Diode Detectors in D-T Fusion Neutron Detection [J].
Liu, Linyue ;
Liu, Ao ;
Bai, Song ;
Lv, Ling ;
Jin, Peng ;
Ouyang, Xiaoping .
SCIENTIFIC REPORTS, 2017, 7
[7]   Diagnostic of fusion neutrons on JET tokamak using diamond detector [J].
Nemtsev, G. ;
Amosov, V. ;
Marchenko, N. ;
Meshchaninov, S. ;
Rodionov, R. ;
Popovichev, S. .
FUSION REACTOR DIAGNOSTICS, 2014, 1612 :93-96
[8]   The fast neutron response of 4H silicon carbide semiconductor radiation detectors [J].
Ruddy, FH ;
Dulloo, AR ;
Seidel, JG ;
Das, MK ;
Ryu, SH ;
Agarwal, AK .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (03) :1666-1670
[9]   CVD diamond as a high bandwidth neutron detector for inertial confinement fusion diagnostics [J].
Schmid, GJ ;
Griffith, RL ;
Izumi, N ;
Koch, JA ;
Lerche, RA ;
Moran, MJ ;
Phillips, TW ;
Turner, RE ;
Glebov, VY ;
Sangster, TC ;
Stoeckl, C .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2003, 74 (03) :1828-1831
[10]   Effect of heavy proton and neutron irradiations on epitaxial 4H-SiC Schottky diodes [J].
Sciortino, S ;
Hartjes, F ;
Lagomarsino, S ;
Nava, F ;
Brianzi, M ;
Cindro, V ;
Lanzieri, C ;
Moll, M ;
Vanni, P .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 552 (1-2) :138-145