Determinants of Quantitative Optic Nerve Measurements Using Spectral Domain Optical Coherence Tomography in a Population-Based Sample of Non-glaucomatous Subjects

被引:95
作者
Cheung, Carol Y. [1 ,2 ,3 ]
Chen, David [1 ,5 ,6 ]
Wong, Tien Y. [1 ,2 ,3 ,7 ]
Tham, Yih Chung [1 ]
Wu, Renyi [1 ]
Zheng, Yingfeng [1 ]
Cheng, Ching Yu [1 ,2 ,3 ,4 ]
Saw, Seang Mei [1 ,7 ]
Baskaran, Mani [1 ]
Leung, Christopher K. [8 ]
Aung, Tin [1 ,3 ]
机构
[1] Natl Eye Ctr, Singapore Eye Res Inst, Singapore 168751, Singapore
[2] Duke Natl Univ Singapore Grad Med Sch, Off Clin Sci, Ctr Quantitat Med, Singapore, Singapore
[3] Natl Univ Singapore, Yong Loo Lin Sch Med, Dept Ophthalmol, Singapore 117595, Singapore
[4] Natl Univ Singapore, Dept Epidemiol & Publ Hlth, Singapore 117548, Singapore
[5] Johns Hopkins Bloomberg Sch Publ Hlth, Baltimore, MD USA
[6] Wilmer Eye Inst, Baltimore, MD 21287 USA
[7] Univ Melbourne, Ctr Eye Res Australia, Melbourne, Vic, Australia
[8] Chinese Univ Hong Kong, Dept Ophthalmol & Visual Sci, Hong Kong, Hong Kong, Peoples R China
基金
新加坡国家研究基金会; 英国医学研究理事会;
关键词
FIBER LAYER THICKNESS; SINGAPORE MALAY EYE; DIAGNOSTIC-PERFORMANCE; DISEASE SEVERITY; DISC SIZE; GLAUCOMA; HEAD; METHODOLOGY; PEOPLE; ERROR;
D O I
10.1167/iovs.11-7481
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To evaluate the ocular and systemic factors influencing measurements of optic nerve head (ONH) parameters and retinal nerve fiber layer (RNFL) thickness with spectral-domain optical coherence tomography (SD-OCT) in healthy Chinese adults. METHODS. Adults ranging in age from 40 to 80 years were consecutively recruited from the population-based Singapore Chinese Eye Study. A SD-OCT instrument was used to measure ONH and RNFL parameters. A total of 542 eyes from 542 non-glaucomatous Chinese subjects were analyzed. Univariable and multiple linear regression analyses were performed to examine the effects of a range of ocular (e.g., intraocular pressure [IOP], axial length [AL], disc area) and systemic (e.g., blood pressure, serum glucose) factors on ONH and RNFL parameters. RESULTS. In multiple regression analyses, neuroretinal rim area was independently associated with age (beta = -0.006, P < 0.001), disc area (beta = -0.183, P < 0.001), IOP (beta = -0.009, P = 0.008), AL (beta = -0.023, P = 0.004), and lens nuclear color (beta = 0.042, P = 0.001). Vertical cup-to-disc ratio was independently correlated with age (beta = 0.003, P < 0.001), disc area (beta = 0.207, P < 0.001), IOP (beta = 0.004, P = 0.014), AL (beta = 0.010, P = 0.008), and lens nuclear color (beta = -0.017, P = 0.006). Average RNFL thickness was independently related to age (beta = -0.204, P = 0.001), disc area (beta = 4.218, P < 0.001), signal strength (beta = 1.348, P < 0.001), and AL (beta = -1.332, P < 0.001). Disc area had the strongest effect on measurements of ONH parameters and RNFL thickness. CONCLUSIONS. In a non-glaucomatous population, optic nerve measurements with SD-OCT vary with disc area, age, IOP, AL, lens nuclear color, and signal strength, but systemic parameters have little influence. This information may be useful for interpretation of SD-OCT measurements. (Invest Ophthalmol Vis Sci. 2011; 52: 9629-9635) DOI: 10.1167/iovs.11-7481
引用
收藏
页码:9629 / 9635
页数:7
相关论文
共 38 条
  • [1] Laser Scanning Tomography of Optic Discs of the Normal Japanese Population in a Population-based Setting
    Abe, Haruki
    Shirakashi, Motohiro
    Tsutsumi, Tae
    Araie, Makoto
    Tomidokoro, Atsuo
    Iwase, Aiko
    Tomita, Goji
    Yamamoto, Tetsuya
    [J]. OPHTHALMOLOGY, 2009, 116 (02) : 223 - 230
  • [2] Determinants of the optic cup to disc ratio in an Asian population - The Singapore Malay Eye Study (SiMES)
    Amerasinghe, Nishani
    Wong, Tien Y.
    Wong, Wan-Ling
    Mitchell, Paul
    Shen, Sunny Y.
    Loon, Seng-Chee
    Saw, Seang-Mei
    Foster, Paul J.
    Aung, Tin
    [J]. ARCHIVES OF OPHTHALMOLOGY, 2008, 126 (08) : 1101 - 1108
  • [3] [Anonymous], 2005, ANN FAM MED, V3, P171
  • [4] MATHEMATIC COUPLING OF DATA - A COMMON SOURCE OF ERROR
    ARCHIE, JP
    [J]. ANNALS OF SURGERY, 1981, 193 (03) : 296 - 303
  • [5] Retinal Nerve Fiber Layer Thickness in Normals Measured by Spectral Domain OCT
    Bendschneider, Delia
    Tornow, Ralf P.
    Horn, Folkert K.
    Laemmer, Robert
    Roessler, Christopher W.
    Juenemann, Anselm G.
    Kruse, Friedrich E.
    Mardin, Christian Y.
    [J]. JOURNAL OF GLAUCOMA, 2010, 19 (07) : 475 - 482
  • [6] The morphology of the optic nerve head in the Singaporean Chinese population (the Tanjong Pagar study): part 2 - biometric and systemic associations
    Bourne, R. R. A.
    Foster, P. J.
    Bunce, C.
    Peto, T.
    Hitchings, R. A.
    Khaw, P. T.
    Seah, S. K. L.
    Garway-Heath, D. F.
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2008, 92 (03) : 310 - 314
  • [7] Determinants of normal retinal nerve fiber layer thickness measured by stratus OCT
    Budenz, Donald L.
    Anderson, Douglas R.
    Varma, Rohit
    Schuman, Joel
    Cantor, Louis
    Savell, Jonathan
    Greenfeld, David S.
    Patella, Vincent Michael
    Quigley, Harry A.
    Tielsch, James
    [J]. OPHTHALMOLOGY, 2007, 114 (06) : 1046 - 1052
  • [8] Budenz Donald L, 2008, Trans Am Ophthalmol Soc, V106, P252
  • [9] Carl Zeiss Meditec Inc., 2010, CIRR HD OCT 5 0 US M
  • [10] Relationship between retinal nerve fiber layer measurement and signal strength in optical coherence tomography
    Cheung, Carol Yim Lui
    Leung, Christopher Kai Shun
    Lin, Dusheung
    Pang, Chi-Pui
    Lam, Dennis Shun Chiu
    [J]. OPHTHALMOLOGY, 2008, 115 (08) : 1347 - 1351