Diagnostic Performance of Thyroglobulin Value in Indeterminate Range in Fine Needle Aspiration Washout Fluid from Lymph Nodes of Thyroid Cancer

被引:50
作者
Sohn, Yu-Mee [2 ]
Kim, Min Jung [1 ]
Kim, Eun-Kyung [1 ]
Kwak, Jin Young [1 ]
机构
[1] Yonsei Univ, Coll Med, Dept Radiol, Res Inst Radiol Sci, Seoul 120752, South Korea
[2] Kyung Hee Univ, Coll Med, Kyung Hee Univ Hosp, Dept Radiol, Seoul, South Korea
关键词
Fine needle aspiration biopsy; thyroglobulin; lymph nodes; ULTRASONOGRAPHIC DIFFERENTIATION; SERUM THYROGLOBULIN; BIOPSY SPECIMENS; CARCINOMA; NECK; METASTASIS; ULTRASOUND; CYTOLOGY; NODULES; UTILITY;
D O I
10.3349/ymj.2012.53.1.126
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: The purpose was to compare the frequency of metastatic and nonmetastatic lymph nodes diagnosed by fine needle aspiration biopsy cytology (FNAC) and thyroglobulin concentration from fine needle aspiration biopsy washout fluid (FNAB-Tg) in an indeterminate range (0.2-100 ng/mL), and to evaluate the most appropriate threshold value of FNAB-Tg in an indeterminate range. Materials and Methods: We performed ultrasound-guided FNAB and FNAB-Tg in suspicious metastatic cervical lymph nodes of papillary thyroid carcinoma and performed surgery. Ninety-five lymph nodes with indeterminate values of FNAB-Tg ranging from 0.2-100 ng/mL in ninety-two patients were included in this study. The diagnostic performances in multiple Tg levels (0.7, 1.0, 5.0, 10.0, 20.0, 50.0) were evaluated to compare with FNAB cytology using sensitivity, specificity, and accuracy with area under the curve (AUC) analysis. Results: Forty-two were metastatic lymph nodes and fifty three were nonmetastatic lymph nodes. FNAB-Tg ranged from 0.22 to 90.9 ng/mL in metastatic lymph nodes (mean; 34.3 +/- 33.3 ng/mL) and 0.20 to 56.7 ng/mL in nonmetastatic lymph nodes (mean; 4.9 +/- 11.1 ng/mL) (p<0.001). The most excellent diagnostic performance was displayed in 5 ng/mL of FNAB-Tg with AUC of 0.76, sensitivity, specificity, accuracy, 69.0, 83.0, and 76.8, respectively. However, there was no significant difference from 10 ng/mL FNAB. Conclusion: We ascertained that 5 ng/mL yielded the most excellent diagnostic performance among FNAB-Tg levels in the present setting with a large series with the indeterminate range (0.2-100 ng/mL) of FNAB-Tg values. These results need additional confirmation under different laboratory conditions.
引用
收藏
页码:126 / 131
页数:6
相关论文
共 26 条
[1]   Utility of Thyroglobulin measurement in fine-needle aspiration biopsy specimens of lymph nodes in the diagnosis of recurrent thyroid carcinoma [J].
Baloch, Zubair W. ;
Barroeta, Julieta E. ;
Walsh, Janet ;
Gupta, Prabodh K. ;
LiVolsi, Virginia A. ;
Langer, Jill E. ;
Mandel, Susan J. .
CYTOJOURNAL, 2008, 5
[2]  
Baskin HJ, 2004, THYROID, V14, P959
[3]   The diagnostic value for differentiated thyroid carcinoma metastases of thyroglobulin (Tg) measurement in washout fluid from fine-needle aspiration biopsy of neck lymph nodes is maintained in the presence of circulating anti-Tg antibodies [J].
Boi, F ;
Baghino, G ;
Atzeni, F ;
Lai, ML ;
Faa, G ;
Mariotti, S .
JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2006, 91 (04) :1364-1369
[4]   EFFICACY OF SONOGRAPHICALLY GUIDED BIOPSY OF THYROID MASSES AND CERVICAL LYMPH-NODES [J].
BOLAND, GW ;
LEE, MJ ;
MUELLER, PR ;
MAYOSMITH, W ;
DAWSON, SL ;
SIMEONE, JF .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 161 (05) :1053-1056
[5]   Significance of low levels of thyroglobulin in fine needle aspirates from cervical lymph nodes of patients with a history of differentiated thyroid cancer [J].
Borel, Anne-Laure ;
Boizel, Robert ;
Faure, Patrice ;
Barbe, Genevieve ;
Boutonnat, Jean ;
Sturm, Nathalie ;
Seigneurin, Daniel ;
Bricault, Ivan ;
Caravel, Jean-Pierre ;
Chaffanjon, Philippe ;
Chabre, Olivier .
EUROPEAN JOURNAL OF ENDOCRINOLOGY, 2008, 158 (05) :691-698
[6]   Identification of a Neck Lump as a Lymph Node Metastasis from an Occult Contralateral Papillary Microcarcinoma of the Thyroid: Key Role of Thyroglobulin Assay in the Fine-Needle Aspirate [J].
Bruno, Rocco ;
Giannasio, Paolo ;
Chiarella, Rosarita ;
Capula, Carmelo ;
Russo, Diego ;
Filetti, Sebastiano ;
Costante, Giuseppe .
THYROID, 2009, 19 (05) :531-533
[7]   Diagnostic utility of thyroglobulin detection in fine-needle aspiration of cervical cystic metastatic lymph nodes from papillary thyroid cancer with negative cytology [J].
Cignarelli, M ;
Ambrosi, A ;
Marino, A ;
Lamacchia, O ;
Campo, M ;
Picca, G ;
Giorgino, F .
THYROID, 2003, 13 (12) :1163-1167
[8]   Thyroglobulin detection in fine-needle aspirates of cervical lymph nodes:: a technique for the diagnosis of metastatic differentiated thyroid cancer [J].
Cunha, Nuno ;
Rodrigues, Fernando ;
Curado, Fatima ;
Ilheu, Olga ;
Cruz, Carlos ;
Naidenov, Plamen ;
Rascao, Maria Joao ;
Ganho, Joao ;
Gomes, Idilio ;
Pereira, Henriques ;
Real, Odete ;
Figueiredo, Paulo ;
Campos, Beatriz ;
Valido, Frederico .
EUROPEAN JOURNAL OF ENDOCRINOLOGY, 2007, 157 (01) :101-107
[9]   COMPARING THE AREAS UNDER 2 OR MORE CORRELATED RECEIVER OPERATING CHARACTERISTIC CURVES - A NONPARAMETRIC APPROACH [J].
DELONG, ER ;
DELONG, DM ;
CLARKEPEARSON, DI .
BIOMETRICS, 1988, 44 (03) :837-845
[10]   Sonographic imaging of thyroid nodules and cervical lymph nodes [J].
Fish, Stephanie A. ;
Langer, Jill E. ;
Mandel, Susan J. .
ENDOCRINOLOGY AND METABOLISM CLINICS OF NORTH AMERICA, 2008, 37 (02) :401-+