Preoperative thoracic false lumen branches are predictors of aortic enlargement after stent grafting for DeBakey IIIb aortic dissection

被引:29
作者
Liu, Feng [1 ]
Ge, Yang Yang [1 ]
Guo, Wei [1 ]
Liu, Xiao Ping [1 ]
Jia, Xin [1 ]
Xiong, Jiang [1 ]
Ma, Xiao Hui [1 ]
机构
[1] Chinese Peoples Liberat Army Gen Hosp, Dept Vasc & Endovasc Surg, 28 Fuxing Rd, Beijing 100853, Peoples R China
关键词
aortic dissection; TEVAR; aortic remodeling; thoracic false lumen branches; ENDOVASCULAR TREATMENT; B DISSECTION; COMPETING RISK; REPAIR; THROMBOSIS; MULTICENTER; PLACEMENT; TRIAL; TEVAR; ANEURYSMS;
D O I
10.1016/j.jtcvs.2017.09.010
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: The study objective was to assess the effect of preoperative thoracic false lumen branches on thoracic aortic enlargement along the stent graft after thoracic endovascular aortic repair for DeBakey IIIb aortic dissection. Methods: From January 2011 to December 2013, 67 patients who underwent thoracic endovascular aortic repair for DeBakey IIIb aortic dissection were retrospectively investigated. We assessed preoperative thoracic false lumen branches and diameter measurements at the level of the tracheal carina. Patients with a median follow-up of 12.2 months (interquartile range, 4.3-26.6 months) were categorized into 2 groups based on a receiver operating characteristic curve analysis: group A (preoperative thoracic false lumen branches >= 8, n = 28) and group B (preoperative thoracic false lumen branches < 8, n = 39). Diameter changes over time were evaluated using a mixed model approach. A multivariate Cox regression analysis was used to study the influence of the preoperative thoracic false lumen branches on thoracic aortic enlargement along the stent graft. Results: Six patients experienced thoracic aortic enlargement along the stent graft during follow-up (6 in group A, 0 in group B). The cumulative thoracic aortic enlargement along the stent-graft rate was higher in group A than in group B (log-rank P <. 01). Diameter data showed significantly more reduction of the thoracic false lumen from preprocedure to 12 months in group B than in group A (change difference, 2.51; standard error, 0.99; P=.01). Complete false lumen thrombosis was more prominent in group B than in group A at each follow-up time point. After multivariate adjustment, preoperative thoracic false lumen branches were associated with thoracic aortic enlargement along the stent graft (hazard ratio, 2.92; 95% confidence interval, 1.06-8.01). Conclusions: Preoperative thoracic false lumen branches are amorphologic predictor of thoracic aortic enlargement along the stent graft in DeBakey IIIb aortic dissection after thoracic endovascular aortic repair.
引用
收藏
页码:21 / +
页数:12
相关论文
共 50 条
  • [21] Re-expansion of Thrombosed False Lumen after Aortic Dissection Due to Collateral Retrograde Flow from the Aortic Branches
    Hamuro, Mamoru
    Miwa, Senri
    Yamamoto, Kenji
    Enomoto, Sakae
    ANNALS OF VASCULAR DISEASES, 2021, 14 (04) : 404 - 406
  • [22] Aortic Remodeling as a Prognostic Factor for Late Aortic Events After Thoracic Endovascular Aortic Repair in Type B Aortic Dissection With Patent False Lumen
    Watanabe, Yoshiki
    Shimamura, Kazuo
    Yoshida, Takuya
    Daimon, Takashi
    Shirakawa, Yukitoshi
    Torikai, Kei
    Sakamoto, Tomohiko
    Shijo, Takayuki
    Toda, Koichi
    Kuratani, Toru
    Sawa, Yoshiki
    JOURNAL OF ENDOVASCULAR THERAPY, 2014, 21 (04) : 517 - 525
  • [23] Antegrade Thoracic Stent Grafting During Repair of Acute DeBakey I Dissection Prevents Development of Thoracoabdominal Aortic Aneurysms
    Pochettino, Alberto
    Brinkman, William T.
    Moeller, Patrick
    Szeto, Wilson Y.
    Moser, William
    Cornelius, Katherine
    Bowen, Frank W.
    Woo, Y. Joseph
    Bavaria, Joseph E.
    ANNALS OF THORACIC SURGERY, 2009, 88 (02) : 482 - 490
  • [24] A computational model for false lumen thrombosis in type B aortic dissection following thoracic endovascular repair
    Menichini, Claudia
    Cheng, Zhuo
    Gibbs, Richard G. J.
    Xu, Xiao Yun
    JOURNAL OF BIOMECHANICS, 2018, 66 : 36 - 43
  • [25] Stent Graft Therapy for False Lumen Aneurysmal Degeneration in Established Type B Aortic Dissection (FADED) Results in Differential Volumetric Remodeling of the Thoracic versus Abdominal Aortic Segments
    Ruddy, Jean Marie
    Reisenman, Paul
    Priestley, Jennifer
    Brewster, Luke P.
    Duwayri, Yazan
    Veeraswamy, Ravi K.
    ANNALS OF VASCULAR SURGERY, 2014, 28 (07) : 1602 - 1609
  • [26] Factors Affecting Optimal Aortic Remodeling After Thoracic Endovascular Aortic Repair of Type B (IIIb) Aortic Dissection
    I-Ming Chen
    Po-Lin Chen
    Chun-Yang Huang
    Shih-Hsien Weng
    Wei-Yuan Chen
    Chun-Che Shih
    CardioVascular and Interventional Radiology, 2017, 40 : 671 - 681
  • [27] Factors Affecting Optimal Aortic Remodeling After Thoracic Endovascular Aortic Repair of Type B (IIIb) Aortic Dissection
    Chen, I-Ming
    Chen, Po-Lin
    Huang, Chun-Yang
    Weng, Shih-Hsien
    Chen, Wei-Yuan
    Shih, Chun-Che
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2017, 40 (05) : 671 - 681
  • [28] Computational Fluid Dynamics Simulations to Predict False Lumen Enlargement After Surgical Repair of Type-A Aortic Dissection
    Shad, Rohan
    Kong, Sandra
    Fong, Robyn
    Quach, Nicolas
    Kasinpila, Patpilai
    Bowles, Cayley
    Lee, Anson
    Hiesinger, William
    SEMINARS IN THORACIC AND CARDIOVASCULAR SURGERY, 2022, 34 (02) : 443 - 448
  • [29] Aortic Remodeling After Custom-Made Candy-Plug for Distal False Lumen Occlusion in Aortic Dissection
    Eleshra, Ahmed
    Rohlffs, Fiona
    Spanos, Konstantinos
    Panuccio, Giuseppe
    Heidemann, Franziska
    Tsilimparis, Nikolaos
    Kolbel, Tilo
    JOURNAL OF ENDOVASCULAR THERAPY, 2021, 28 (03) : 399 - 406
  • [30] Temporal pattern of aortic remodelling after endovascular treatment for chronic DeBakey IIIb dissection
    Kim, Tae-Hoon
    Song, Suk-Won
    Heo, Woon
    Lee, Kwang-Hun
    Yoo, Kyung-Jong
    Lee, Hye Sun
    Cho, Bum-Koo
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2020, 31 (02) : 232 - 238