Effect of sutureless implantation of the Perceval S aortic valve bioprosthesis on intraoperative and early postoperative outcomes

被引:143
|
作者
Flameng, Willem [1 ]
Herregods, Marie-Christine [1 ]
Hermans, Hadewich [1 ]
Van der Mieren, Gerry [1 ]
Vercalsteren, Monique [1 ]
Poortmans, Gert [1 ]
Van Hemelrijck, Jan [1 ]
Meuris, Bart [1 ]
机构
[1] Katholieke Univ Leuven, Dept Cardiovasc Dis, Louvain, Belgium
关键词
HIGH-RISK PATIENTS; REPLACEMENT; STENOSIS; PROSTHESIS;
D O I
10.1016/j.jtcvs.2011.02.021
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Prolonged aortic crossclamping can increase mortality and morbidity after aortic valve replacement in elderly and high-risk patients. Sutureless implantation of the prosthesis has the potential to shorten aortic crossclamp time. Methods: The Perceval S valve (Sorin Biomedica Cardio Srl, Sallugia, Italy), a sutureless implantable aortic bioprosthesis, was used in 32 patients (median age, 78 years; median logistic euroSCORE, 9.99) requiring aortic valve replacement with or without concomitant coronary artery bypass grafting. Hemodynamic parameters and clinical outcome were obtained at discharge, at 6 months, and up to 1 year postoperatively. Results: Aortic crossclamp time needed for aortic valve replacement was 18 +/- 6 minutes. Hemodynamics at discharge showed good function of all Perceval S valves with low transvalvular pressure gradients (mean, 12 +/- 5 mm Hg and peak, 23 +/- 9 mm Hg) and low incidence of paravalvular or valvular leakage. Operative mortality was 0%. Follow-up at 1 year showed 3 non-valve-related deaths. Survivors showed good clinical outcome and stable hemodynamic function of the valve prosthesis, except for 1 patient in whom endocarditis developed. Despite a moderate decrease in platelet counts persisting up to 12 months, freedom of bleeding and thromboembolic events was 100%. Conclusions: It is possible to implant a well-functioning sutureless stent-mounted valve in the aortic position in less than 20 minutes of aortic crossclamping. This is associated with excellent early clinical and hemodynamic outcome in high-risk patients. Moderate changes in hematologic parameters persisted but were not related to clinical events. (J Thorac Cardiovasc Surg 2011;142:1453-7)
引用
收藏
页码:1453 / 1457
页数:5
相关论文
共 50 条
  • [41] Single-center early experience with sutureless valve Perceval: focus onto size gaining
    Zanobini, Marco
    Loardi, Claudia
    Mammana, Francesco L.
    Kassem, Samer
    Alamanni, Francesco
    Di Minno, Alessandro
    Poggio, Paolo
    Myasoedova, Veronika
    Saccocci, Matteo
    JOURNAL OF CARDIOVASCULAR SURGERY, 2017, 58 (06) : 951 - 952
  • [42] Early and Long-Term Clinical and Echocardiographic Outcomes of Sutureless vs. Sutured Bioprosthesis for Aortic Valve Replacement
    Dokollari, Aleksander
    Torregrossa, Gianluca
    Bisleri, Gianluigi
    Hassanabad, Ali Fatehi
    Sa, Michel Pompeu
    Sicouri, Serge
    Veshti, Altin
    Prifti, Edvin
    Bacchi, Beatrice
    Cabrucci, Francesco
    Ramlawi, Basel
    Bonacchi, Massimo
    JOURNAL OF CARDIOVASCULAR DEVELOPMENT AND DISEASE, 2023, 10 (05)
  • [43] Sutureless valve implantation in a patient with bicuspid aortic valve
    Santarpino, Giuseppe
    Pfeiffer, Steffen
    Fischlein, Theodor
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2012, 157 (02) : E21 - E22
  • [44] Aortic Valve Replacement with the Perceval S Bioprosthesis: Single-Center Experience in 143 Patients
    Zannis, Konstantinos
    Joffre, Jeremie
    Czitrom, Daniel
    Folliguet, Thierry
    Noghin, Milena
    Lansac, Emmanuel
    Mitchell-Heggs, Laurens
    Debauchez, Mathieu
    Laborde, Francois
    JOURNAL OF HEART VALVE DISEASE, 2014, 23 (06) : 795 - 802
  • [45] Clinical outcomes and prognostic factors of transcatheter aortic valve implantation in bicuspid aortic valve patients
    Yoon, Sung-Han
    Sharma, Rahul
    Chakravarty, Tarun
    Kawamori, Hiroyuki
    Maeno, Yoshio
    Miyasaka, Masaki
    Nomura, Takahiro
    Ochiai, Tomoki
    Israr, Sharjeel
    Rami, Tanya
    Nakamura, Mamoo
    Chen, Wen
    Makkar, Raj R.
    ANNALS OF CARDIOTHORACIC SURGERY, 2017, 6 (05) : 463 - 472
  • [46] Sutureless Aortic Valve Replacement with Perceval Bioprosthesis Superior to Transcatheter Aortic Valve Implantation: A Promising Option for the Gray-Zone of Aortic Valve Replacement Procedures-A State-of-the-Art Systematic Review, Meta-Analysis, and Future Directions
    Ali-Hasan-Al-Saegh, Sadeq
    Takemoto, Sho
    Shafiei, Saeed
    Yavuz, Senol
    Rad, Arian Arjomandi
    Amanov, Lukman
    Merzah, Ali Saad
    Salman, Jawad
    Ius, Fabio
    Kaufeld, Tim
    Schmack, Bastian
    Popov, Aron-Frederik
    Sabashnikov, Anton
    Ruhparwar, Arjang
    Zubarevich, Alina
    Weymann, Alexander
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (16)
  • [47] Early and intermediate outcome after aortic valve replacement with a sutureless bioprosthesis: Results of a multicenter study
    Rubino, Antonino S.
    Santarpino, Giuseppe
    De Praetere, Herbert
    Kasama, Keiichiro
    Dalen, Magnus
    Sartipy, Ulrik
    Lahtinen, Jarmo
    Heikkinen, Jouni
    Deste, Wanda
    Pollari, Francesco
    Svenarud, Peter
    Meuris, Bart
    Fischlein, Theodor
    Mignosa, Carmelo
    Biancari, Fausto
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2014, 148 (03) : 865 - 871
  • [48] Postoperative Conduction Disorders after Implantation of the Self-Expandable Suture less Perceval S Bioprosthesis
    van Boxtel, Astrid G. M.
    Houthuizen, Patrick
    Hamad, Mohamed A. Soliman
    Sjatskig, Jelena
    Tan, Erwin
    Prinzen, Frits W.
    van Straten, Albert H. M.
    JOURNAL OF HEART VALVE DISEASE, 2014, 23 (03) : 319 - 324
  • [49] Short- and mid-term safety and effectiveness of transcatheter aortic valve implantation in a failing surgical aortic bioprosthesis
    Ong, Sea Hing
    Bauernschmitt, Robert
    Schuler, Gerhard
    Mueller, Ralf
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2012, 42 (02) : 268 - 276
  • [50] Transcatheter Aortic Valve Implantation Impact on Clinical and Valve-Related Outcomes
    Webb, John G.
    Altwegg, Lukas
    Boone, Robert H.
    Cheung, Anson
    Ye, Jian
    Lichtenstein, Samuel
    Lee, May
    Masson, Jean Bernard
    Thompson, Christopher
    Moss, Robert
    Carere, Ron
    Munt, Brad
    Nietlispach, Fabian
    Humphries, Karin
    CIRCULATION, 2009, 119 (23) : 3009 - 3016