摘要
Issues associated with deactivating clumped spores of a biological pathogen are discussed within the context of decontaminating a civil facility using reactive gases. It is argued that gases will prove necessary to fully complete a decontamination and restoration operation following contamination with a biological pathogen. This is simply due to the fact that pathogenic agents may have found their way into hidden and otherwise inaccessible spaces, such as air ducts and cracks, where liquid-based reagents may prove impractical to employ. Results are given for ozone de-activating both clumped and dirty spores of the pathogen surrogate B. globigii. Re-hydration of dry spores is found to greatly enhance the effectiveness of ozone. The re-hydration process is found to require hours if moist air is employed as the source of water. At high relative humidity, capillary condensation of water within spore clumps is found to adversely effect the global deactivation rate in clumped spores. The cleanliness of the spores did not significantly affect the global kinetics. Using selected electronic materials, estimates of collateral damage induced by the reactive gas are also reported.
引用
收藏
页码:285 / 294
页数:10
相关论文
共 14 条
[1]  
[Anonymous], FREE RADICALS BIOL M
[2]   An investigation of the merits of ozone as an aerial disinfectant [J].
Elford, WJ ;
Van Den Ende, J .
JOURNAL OF HYGIENE, 1942, 42 (03) :240-265
[3]   INACTIVATION OF BACILLUS SPORES BY GASEOUS OZONE [J].
ISHIZAKI, K ;
SHINRIKI, N ;
MATSUYAMA, H .
JOURNAL OF APPLIED BACTERIOLOGY, 1986, 60 (01) :67-72
[4]  
LANGLAIS B, 1991, OZONE WATER TREATMEN, pCH2
[5]   OZONE DECONTAMINATION OF BIOCLEAN ROOMS [J].
MASAOKA, T ;
KUBOTA, Y ;
NAMIUCHI, S ;
TAKUBO, T ;
UEDA, T ;
SHIBATA, H ;
NAKAMURA, H ;
YOSHITAKE, J ;
YAMAYOSHI, T ;
DOI, H ;
KAMIKI, T .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1982, 43 (03) :509-513
[6]  
MOORE WJ, 1972, PHYSICAL CHEM
[7]   SORPTION OF WATER VAPOUR AND NITROGEN GAS BY BACTERIAL SPORES [J].
NEIHOF, R ;
THOMPSON, JK ;
DEITZ, VR .
NATURE, 1967, 216 (5122) :1304-&
[8]   OZONE AND GLYCOL VAPOR DECONTAMINATION OF AIR IN A CLOSED ROOM [J].
PELLEU, GB ;
BERRY, RF ;
HOLLEMAN, NG .
JOURNAL OF DENTAL RESEARCH, 1974, 53 (05) :1132-1137
[9]   Measurement of water vapor sorption by single biological aerosols [J].
Rubel, GO .
AEROSOL SCIENCE AND TECHNOLOGY, 1997, 27 (04) :481-490
[10]   REACTION OF CW AGENTS SIMULANTS ON SURFACES IN THE PRESENCE OF O-3, UV AND O-3 + UV [J].
SNELSON, A ;
TAYLOR, K ;
ONEILL, HJ .
JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-ENVIRONMENTAL SCIENCE AND ENGINEERING & TOXIC AND HAZARDOUS SUBSTANCE CONTROL, 1984, 19 (07) :775-790