Inter-laboratory analysis of selected genetically modified plant reference materials with digital PCR

被引:10
|
作者
Dobnik, David [1 ]
Demsar, Tina [1 ]
Huber, Ingrid [2 ]
Gerdes, Lars [2 ]
Broeders, Sylvia [3 ]
Roosens, Nancy [3 ]
Debode, Frederic [4 ]
Berben, Gilbert [4 ]
Zel, Jana [1 ]
机构
[1] Natl Inst Biol NIB, Dept Biotechnol & Syst Biol, Vecna Pot 111, Ljubljana 1000, Slovenia
[2] Bavarian Hlth & Food Safety Author LGL, Vet Str 2, D-85764 Oberschleissheim, Germany
[3] Sci Inst Publ Hlth WIV ISP, J Wytsmanstr 14, B-1050 Brussels, Belgium
[4] Walloon Agr Res Ctr CRA W, Chaussee Namur 24, B-5030 Gembloux, Belgium
关键词
Digital PCR; Droplet digital PCR; Absolute quantification; Reference materials; GMO quantification; POLYMERASE-CHAIN-REACTION; MULTIPLEX QUANTIFICATION; MODIFIED ORGANISMS; GMO DETECTION; DNA; LECTIN;
D O I
10.1007/s00216-017-0711-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Digital PCR (dPCR), as a new technology in the field of genetically modified (GM) organism (GMO) testing, enables determination of absolute target copy numbers. The purpose of our study was to test the transferability of methods designed for quantitative PCR (qPCR) to dPCR and to carry out an inter-laboratory comparison of the performance of two different dPCR platforms when determining the absolute GM copy numbers and GM copy number ratio in reference materials certified for GM content in mass fraction. Overall results in terms of measured GM% were within acceptable variation limits for both tested dPCR systems. However, the determined absolute copy numbers for individual genes or events showed higher variability between laboratories in one third of the cases, most possibly due to variability in the technical work, droplet size variability, and analysis of the raw data. GMO quantification with dPCR and qPCR was comparable. As methods originally designed for qPCR performed well in dPCR systems, already validated qPCR assays can most generally be used for dPCR technology with the purpose of GMO detection.
引用
收藏
页码:211 / 221
页数:11
相关论文
共 50 条
  • [1] Inter-laboratory analysis of selected genetically modified plant reference materials with digital PCR
    David Dobnik
    Tina Demšar
    Ingrid Huber
    Lars Gerdes
    Sylvia Broeders
    Nancy Roosens
    Frederic Debode
    Gilbert Berben
    Jana Žel
    Analytical and Bioanalytical Chemistry, 2018, 410 : 211 - 221
  • [2] Development and inter-laboratory assessment of droplet digital PCR assays for multiplex quantification of 15 genetically modified soybean lines
    Kosir, Alexandra Bogozalec
    Spilsberg, Bjorn
    Holst-Jensen, Arne
    Zel, Jana
    Dobnik, David
    SCIENTIFIC REPORTS, 2017, 7
  • [3] Critical assessment of digital PCR for the detection and quantification of genetically modified organisms
    Demeke, Tigst
    Dobnik, David
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2018, 410 (17) : 4039 - 4050
  • [4] Inter-laboratory assessment of different digital PCR platforms for quantification of human cytomegalovirus DNA
    Pavsic, Jernej
    Devonshire, Alison
    Blejec, Andrej
    Foy, Carole A.
    Van Heuverswyn, Fran
    Jones, Gerwyn M.
    Schimmel, Heinz
    Zel, Jana
    Huggett, Jim F.
    Redshaw, Nicholas
    Karczmarczyk, Maria
    Mozioglu, Erkan
    Akyurek, Sema
    Akgoz, Muslum
    Milavec, Mojca
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2017, 409 (10) : 2601 - 2614
  • [5] Digital PCR for the characterization of reference materials
    Cleveland, Megan H.
    He, Hua-Jun
    Milavec, Mojca
    Bae, Young-Kyung
    Vallone, Peter M.
    Huggett, Jim F.
    MOLECULAR ASPECTS OF MEDICINE, 2024, 96
  • [6] Inter-laboratory assessment of different digital PCR platforms for quantification of human cytomegalovirus DNA
    Jernej Pavšič
    Alison Devonshire
    Andrej Blejec
    Carole A. Foy
    Fran Van Heuverswyn
    Gerwyn M. Jones
    Heinz Schimmel
    Jana Žel
    Jim F. Huggett
    Nicholas Redshaw
    Maria Karczmarczyk
    Erkan Mozioğlu
    Sema Akyürek
    Müslüm Akgöz
    Mojca Milavec
    Analytical and Bioanalytical Chemistry, 2017, 409 : 2601 - 2614
  • [7] Droplet digital PCR for routine analysis of genetically modified foods (GMO) - A comparison with real-time quantitative PCR
    Iwobi, Azuka
    Gerdes, Lars
    Busch, Ulrich
    Pecoraro, Sven
    FOOD CONTROL, 2016, 69 : 205 - 213
  • [8] Inter-laboratory comparison of eleven quantitative or digital PCR assays for detection of proviral bovine leukemia virus in blood samples
    Pluta, Aneta
    Jaworski, Juan Pablo
    Droscha, Casey
    Vanderweele, Sophie
    Taxis, Tasia M.
    Valas, Stephen
    Brnic, Dragan
    Jungic, Andreja
    Ruano, Maria Jose
    Sanchez, Azucena
    Murakami, Kenji
    Nakamura, Kurumi
    Puentes, Rodrigo
    De Brun, Mlaureana
    Ruiz, Vanesa
    Gomez, Marla Eliana Ladera
    Lendez, Pamela
    Dolcini, Guillermina
    Camargos, Marcelo Fernandes
    Fonseca, Antonio
    Barua, Subarna
    Wang, Chengming
    Giza, Aleksandra
    Kuzmak, Jacek
    BMC VETERINARY RESEARCH, 2024, 20 (01)
  • [9] Inter-laboratory Testing of GMO Detection by Combinatory SYBR®Green PCR Screening (CoSYPS)
    Barbau-Piednoir, Elodie
    Stragier, Pieter
    Roosens, Nancy
    Mazzara, Marco
    Savini, Cristian
    Van den Eede, Guy
    Van den Bulcke, Marc
    FOOD ANALYTICAL METHODS, 2014, 7 (08) : 1719 - 1728
  • [10] Inter laboratory Validation of Quantitative Duplex Real-Time PCR Method for Screening Analysis of Genetically Modified Maize
    Takabatake, Reona
    Koiwa, Tomohiro
    Kasahara, Masaki
    Takashima, Kaori
    Futo, Satoshi
    Minegishi, Yasutaka
    Akiyama, Hiroshi
    Teshima, Reiko
    Oguchi, Taichi
    Mano, Junichi
    Furui, Satoshi
    Kitta, Kazumi
    FOOD HYGIENE AND SAFETY SCIENCE, 2011, 52 (04): : 265 - 269