ActiGraph and Actical Physical Activity Monitors: A Peek under the Hood

被引:268
作者
John, Dinesh [1 ]
Freedson, Patty [1 ]
机构
[1] Univ Massachusetts, Dept Kinesiol, Amherst, MA 01003 USA
基金
美国国家卫生研究院;
关键词
ACTIVITY MONITOR; ACCELEROMETER; PHYSICAL ACTIVITY; ACCELEROMETER;
D O I
10.1249/MSS.0b013e3182399f5e
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
JOHN, D., and P. FREEDSON. ActiGraph and Actical Physical Activity Monitors: A Peek under the Hood. Med. Sci. Sports Exerc., Vol. 44, No. 1S, pp. S86-S89, 2012. Since the 1980s, accelerometer-based activity monitors have been used by researchers to quantify physical activity. The technology of these monitors has continuously evolved. For example, changes have been made to monitor hardware (type of sensor (e. g., piezoelectric, piezoresistive, capacitive)) and output format (counts vs raw signal). Commonly used activity monitors belong to the ActiGraph and the Actical families. This article presents information on several electromechanical aspects of these commonly used activity monitors. The majority of the article focuses on the evolution of the ActiGraph activity monitor by describing the differences among the 7164, the GT1M, and the GT3X models. This is followed by brief descriptions of the influences of device firmware and monitor calibration status. We also describe the Actical, but the discussion is short because this device has not undergone any major changes since it was first introduced. This article may help researchers gain a better understanding of the functioning of activity monitors. For example, a common misconception among physical activity researchers is that the ActiGraph GT1M and GT3X are piezoelectric sensor-based monitors. Thus, this information may also help researchers to describe these monitors more accurately in scientific publications.
引用
收藏
页码:S86 / S89
页数:4
相关论文
共 5 条
  • [1] 3-DIRECTIONAL ACCELEROMETER FOR ANALYZING BODY MOVEMENTS
    CAVAGNA, G
    SAIBENE, F
    MARGARIA, R
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1961, 16 (01) : 191 - &
  • [2] Karcher J., 1922, Journal of the Franklin Institute, V194, P815
  • [3] Validation and comparison of ActiGraph activity monitors
    Sasaki, Jeffer E.
    John, Dinesh
    Freedson, Patty S.
    [J]. JOURNAL OF SCIENCE AND MEDICINE IN SPORT, 2011, 14 (05) : 411 - 416
  • [4] Walter PL, 1997, SOUND VIB, V31, P16
  • [5] PORTABLE ACCELEROMETER DEVICE FOR MEASURING HUMAN ENERGY-EXPENDITURE
    WONG, TC
    WEBSTER, JG
    MONTOYE, HJ
    WASHBURN, R
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1981, 28 (06) : 467 - 471