On-line rheological characterization of semi-solid formulations

被引:13
作者
Qwist, Pernille Kjaergaard [1 ,2 ]
Sander, Camilla [2 ]
Okkels, Fridolin [3 ]
Jessen, Vibeke [2 ]
Baldursdottir, Stefania [1 ,4 ]
Rantanen, Jukka [1 ]
机构
[1] Univ Copenhagen, Fac Hlth & Med Sci, Dept Pharm, Univ Pk 2, Copenhagen, Denmark
[2] LEO Pharma AS, Ind Pk 55, Ballerup, Denmark
[3] Fluidan ApS, Diplomvej Bldg 381, Lyngby, Denmark
[4] Prof Claraplein 14, Antwerp, Belgium
关键词
Rheology; On-line; Hydroxyethyl cellulose gel; Semi-solid; Process analytical technology (PAT); Pressure difference apparatus (PDA); POLYMER MELTS; SPECTROSCOPY; FLOW; VISCOMETER; VISCOSITY; BATCH; TIME;
D O I
10.1016/j.ejps.2018.11.014
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
The rheological profile of a semi-solid product is a critical quality attribute. To monitor changes of this attribute during manufacturing, it would be beneficial to measure the rheological parameters in an on-line or in-line mode and implement this as a part of a control strategy for manufacturing of semi-solids. None of the process analytical technology (PAT) tools for measuring the rheological parameters have yet been widely accepted in the pharmaceutical area, as most of the equipment can only measure viscosity. Therefore, an automated system based on the measurement of pressure difference across both a topology optimized channel and a tube geometry (capillary viscometer) was investigated. The Pressure Difference Apparatus (PDA) can sample from the bulk intermediate/product stream and press the sample through the apparatus at different flow rates to yield a frequency sweep (G' and G '') and a flow curve (viscosity). A calibration model was successfully prepared and verified with hydroxyethyl cellulose gels with polymer content varying from 1.0 to 1.5% (w/w) resulting in gels of different viscosities. The calibration model was used on-line during manufacturing of a gel and manufacturing changes related to dilution of the product were clearly reflected in the batch evolution profiles. The measurements with the PDA reflected the shear rate and frequency ranges relevant for manufacturing and thereby complemented the rheology measurements obtained with a standard rheometer with real time data.
引用
收藏
页码:36 / 42
页数:7
相关论文
共 32 条
[1]  
[Anonymous], 2004, GUIDANCE IND 5 FRAME
[2]  
[Anonymous], 2009, Pharmacopeial Forum, V35, P750, DOI [DOI 10.14227/DT170410P12, 10.14227/DT170410P12]
[3]  
[Anonymous], 2009, ICH HARMONISED TRIPA
[4]   First normal stress difference measurements for polymer melts at high shear rates in a slit-die using hole and exit pressure data [J].
Baird, Donald G. .
JOURNAL OF NON-NEWTONIAN FLUID MECHANICS, 2008, 148 (1-3) :13-23
[5]   The oscillatory squeeze flow rheometer: comprehensive theory and a new experimental facility [J].
Bell, D. ;
Binding, D. M. ;
Walters, K. .
RHEOLOGICA ACTA, 2006, 46 (01) :111-121
[6]   Correlation between in-line measurements of tomato ketchup shear viscosity and extensional viscosity [J].
Berta, Marco ;
Wiklund, Johan ;
Kotze, Reinhardt ;
Stading, Mats .
JOURNAL OF FOOD ENGINEERING, 2016, 173 :8-14
[7]   In-line UV spectroscopy for the quantification of low-dose active ingredients during the manufacturing of pharmaceutical semi-solid and liquid formulations [J].
Bostijn, N. ;
Hellings, M. ;
Van der Veen, M. ;
Vervaet, C. ;
De Beer, T. .
ANALYTICA CHIMICA ACTA, 2018, 1013 :54-62
[8]   In situ rheological monitoring in semi-batch emulsification process for cosmetic lotion production [J].
Choplin, L ;
Torandell, S ;
Servoin, J .
CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 1998, 76 (03) :506-510
[9]   CONVERGING FLOW OF POLYMER MELTS [J].
HUANG, DC ;
SHROFF, RN .
JOURNAL OF RHEOLOGY, 1981, 25 (06) :605-617
[10]   CORRELATION OF DYNAMIC AND STEADY FLOW VISCOSITIES [J].
COX, WP ;
MERZ, EH .
JOURNAL OF POLYMER SCIENCE, 1958, 28 (118) :619-622