We develop a heterodyne-detected polarization coherent anti-Stokes Raman scattering (HP-CARS) microscopy for high sensitive and high contrast molecular vibration imaging. The HP-CARS technique, which utilizes interference of the weak resonant CARS signal and the relatively intense local oscillator field generated simultaneously within the same focal excitation volume of the sample for optical heterodyne detection, yields an approximately sevenfold improvement in vibrational contrast compared with local oscillator CARS, while exhibiting a 12-fold amplification of the resonant signal compared with P-CARS. We demonstrate this method by imaging both 4.69 mu m polystyrene beads and unstained human epithelial cells in aqueous environments. (C) 2008 American Institute of Physics.
引用
收藏
页数:3
相关论文
共 14 条
[1]   Polarization coherent anti-Stokes Raman scattering microscopy [J].
Cheng, JX ;
Book, LD ;
Xie, XS .
OPTICS LETTERS, 2001, 26 (17) :1341-1343
[2]   An epi-detected coherent anti-stokes raman scattering (E-CARS) microscope with high spectral resolution and high sensitivity [J].
Cheng, JX ;
Volkmer, A ;
Book, LD ;
Xie, XS .
JOURNAL OF PHYSICAL CHEMISTRY B, 2001, 105 (07) :1277-1280
[3]  
CLARK JH, 1988, ADV NONLINEAR SPECTR
[4]   Simplified setup for high-resolution spectroscopy that uses ultrashort pulses [J].
Gershgoren, E ;
Bartels, RA ;
Fourkas, JT ;
Tobey, R ;
Murnane, MM ;
Kapteyn, HC .
OPTICS LETTERS, 2003, 28 (05) :361-363
[5]   High-contrast chemical imaging with gated heterodyne coherent anti-Stokes Raman scattering microscopy [J].
Greve, M ;
Bodermann, B ;
Telle, HR ;
Baum, P ;
Riedle, E .
APPLIED PHYSICS B-LASERS AND OPTICS, 2005, 81 (07) :875-879
[6]   Spectral focusing: High spectral resolution spectroscopy with broad-bandwidth laser pulses [J].
Hellerer, T ;
Enejder, AMK ;
Zumbusch, A .
APPLIED PHYSICS LETTERS, 2004, 85 (01) :25-27
[7]   Monitoring of lipid storage in Caenorhabditis elegans using coherent anti-Stokes Raman scattering (CARS) microscopy [J].
Hellerer, Thomas ;
Axaeng, Claes ;
Brackmann, Christian ;
Hillertz, Per ;
Pilon, Marc ;
Enejder, Annika .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2007, 104 (37) :14658-14663
[8]   OBSERVATION OF COHERENT ANTI-STOKES RAMAN-SCATTERING FROM LIQUID WATER [J].
ITZKAN, I ;
LEONARD, DA .
APPLIED PHYSICS LETTERS, 1975, 26 (03) :106-108
[9]   High spectral resolution multiplex CARS spectroscopy using chirped pulses [J].
Knutsen, KP ;
Johnson, JC ;
Miller, AE ;
Petersen, PB ;
Saykally, RJ .
CHEMICAL PHYSICS LETTERS, 2004, 387 (4-6) :436-441
[10]   Near-field effects on coherent anti-Stokes Raman scattering microscopy imaging [J].
Liu, Cheng ;
Huang, Zhiwei ;
Lu, Fake ;
Zheng, Wei ;
Hutmacher, Dietmar W. ;
Sheppard, Colin .
OPTICS EXPRESS, 2007, 15 (07) :4118-4131