Pressure drop of R134a in mini channels with micro pin fins during flow boiling

被引:12
|
作者
Li, Jie [1 ]
Zhang, Dalin [1 ]
Yubing, Wang [1 ]
Chen, Weijian [1 ]
Zhu, Guangya [1 ]
机构
[1] Nanjing Univ Aeronaut & Astronaut, Coll Aerosp Engn, Key Lab Aircraft Environm Control & Life Support, Minist Ind & Informat Technol, Nanjing, Peoples R China
基金
中国国家自然科学基金;
关键词
Mini channel; Micro pin fin; Flow boiling; Pressure drop; Two-phase friction multiplier; HEAT-TRANSFER; SERRATED FINS; LIQUID FLOW; PERFORMANCE; OPTIMIZATION; SHAPES; SINKS; TUBES; WATER; BANK;
D O I
10.1016/j.applthermaleng.2022.119195
中图分类号
O414.1 [热力学];
学科分类号
摘要
Flow boiling in mini channel with micro pin fin arrays is a promising technology for thermal management in various fields such as microelectronics, energy utilization and national defence. Understanding its flow char-acteristics is the pave stone for further structure optimization of two-phase microchannel heat sinks. However, previous studies paid few attentions to the effect of different structural parameters on its flow performance, especially for the application with long channels for practical evaporators in aircraft environmental control systems. In this paper, an experimental system was set up to investigate the flow boiling pressure drops of refrigerant R134a in a 300 mm long channel with micro pin fin arrays. The flow characteristics of staggered diamond pin fin arrays with different channel widths of 1.0, 1.2 and 1.4 mm and fin angles of 30 degrees, 60 degrees and 90 degrees were comprehensively investigated. The pin fins with a height of 0.5 mm were arranged in the rectangular channel through 3D printing. Two-phase pressure drops in the test section were then measured. The test range of vapor quality, mass flux, heat flux and saturation pressure were 0-1, 200-500 kg/m2s, 10.0-37.5 kW/m2 and 390-700 kPa respectively. Experimental results revealed that the smaller channel width and the greater diamond angle resulted in the greater two-phase pressure drops. The heat flux showed an insignificant influence on the two-phase pressure drops. The existing empirical correlations for pressure drops were evaluated and failed to predict the present experimental data. A new one with the consideration of pin fin structure parameters was then developed to improve the prediction accuracy with the maximum mean absolute deviation of 5.4 %. The pro-posed correlation can illuminate future study on flow boiling in mini channel with pin fin arrays and be bene-ficial for the practical design of two-phase microchannel heat sinks.
引用
收藏
页数:17
相关论文
共 50 条
  • [41] Experimental investigation on flow boiling heat transfer of R134a in a minichannel heatsink with copper foam fins
    Gao W.
    Fu K.
    Xu X.
    Liang X.
    Zhongguo Kexue Jishu Kexue/Scientia Sinica Technologica, 2022, 52 (02): : 333 - 342
  • [42] R134a condensation flow regime and pressure drop in horizontal microchannals cooled symmetrically and asymmetrically
    Wang, Ji
    Wang, Jin
    Li, Jun Ming
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2017, 115 : 1091 - 1102
  • [43] Flow boiling in a 1.1 mm tube with R134a: Experimental results and comparison with model
    Shiferaw, D.
    Karayiannis, T. G.
    Kenning, D. B. R.
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2009, 48 (02) : 331 - 341
  • [44] Experimental study on condensation heat transfer of R134a in mini channel with micro diamond fins
    Liu R.
    Li J.
    Wang Y.
    Zhan H.
    Zhang D.
    Huagong Xuebao/CIESC Journal, 2022, 73 (11): : 4938 - 4947
  • [45] Detailed experimental investigations on frictional pressure drop of R134a during flow boiling in 5 mm diameter channel: The influence of acceleration pressure drop component
    Muszynski, Tomasz
    Andrzejczyk, Rafal
    Dorao, Carlos Alberto
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2017, 82 : 163 - 173
  • [46] Machine learning algorithms to predict flow boiling pressure drop in mini/micro-channels based on universal consolidated data
    Qiu, Yue
    Garg, Deepak
    Kim, Sung-Min
    Mudawar, Issam
    Kharangate, Chirag R.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2021, 178
  • [47] Flow boiling pressure drop correlation in small to micro passages
    Al-Zaidi, Ali H.
    Mahmoud, Mohamed M.
    Karayiannis, Tassos G.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2024, 224
  • [48] Comparison of flow boiling pressure drop and heat transfer of R134a with low GWP alternative R1234ze(E) in a dimpled flat duct
    Gao, Yuping
    Feng, Ye
    Tang, Ke
    Hrnjak, Pega
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2020, 119 : 165 - 174
  • [49] Convective boiling heat transfer and pressure drop characteristics of R134A in a microfinned helically coiled tube
    Cui, Wenzhi
    Li, Longjian
    Xin, Mingdao
    Chen, Qinghua
    Liao, Quan
    Jen, Tien-Chien
    HT2005: Proceedings of the ASME Summer Heat Transfer Conference 2005, Vol 2, 2005, : 343 - 348
  • [50] Flow boiling heat transfer of R134a in multi microchannels
    Fayyadh, E. M.
    Mahmoud, M. M.
    Sefiane, K.
    Karayiannis, T. G.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2017, 110 : 422 - 436