Pressure drop of R134a in mini channels with micro pin fins during flow boiling

被引:12
|
作者
Li, Jie [1 ]
Zhang, Dalin [1 ]
Yubing, Wang [1 ]
Chen, Weijian [1 ]
Zhu, Guangya [1 ]
机构
[1] Nanjing Univ Aeronaut & Astronaut, Coll Aerosp Engn, Key Lab Aircraft Environm Control & Life Support, Minist Ind & Informat Technol, Nanjing, Peoples R China
基金
中国国家自然科学基金;
关键词
Mini channel; Micro pin fin; Flow boiling; Pressure drop; Two-phase friction multiplier; HEAT-TRANSFER; SERRATED FINS; LIQUID FLOW; PERFORMANCE; OPTIMIZATION; SHAPES; SINKS; TUBES; WATER; BANK;
D O I
10.1016/j.applthermaleng.2022.119195
中图分类号
O414.1 [热力学];
学科分类号
摘要
Flow boiling in mini channel with micro pin fin arrays is a promising technology for thermal management in various fields such as microelectronics, energy utilization and national defence. Understanding its flow char-acteristics is the pave stone for further structure optimization of two-phase microchannel heat sinks. However, previous studies paid few attentions to the effect of different structural parameters on its flow performance, especially for the application with long channels for practical evaporators in aircraft environmental control systems. In this paper, an experimental system was set up to investigate the flow boiling pressure drops of refrigerant R134a in a 300 mm long channel with micro pin fin arrays. The flow characteristics of staggered diamond pin fin arrays with different channel widths of 1.0, 1.2 and 1.4 mm and fin angles of 30 degrees, 60 degrees and 90 degrees were comprehensively investigated. The pin fins with a height of 0.5 mm were arranged in the rectangular channel through 3D printing. Two-phase pressure drops in the test section were then measured. The test range of vapor quality, mass flux, heat flux and saturation pressure were 0-1, 200-500 kg/m2s, 10.0-37.5 kW/m2 and 390-700 kPa respectively. Experimental results revealed that the smaller channel width and the greater diamond angle resulted in the greater two-phase pressure drops. The heat flux showed an insignificant influence on the two-phase pressure drops. The existing empirical correlations for pressure drops were evaluated and failed to predict the present experimental data. A new one with the consideration of pin fin structure parameters was then developed to improve the prediction accuracy with the maximum mean absolute deviation of 5.4 %. The pro-posed correlation can illuminate future study on flow boiling in mini channel with pin fin arrays and be bene-ficial for the practical design of two-phase microchannel heat sinks.
引用
收藏
页数:17
相关论文
共 50 条
  • [21] Experimental investigation on the heat transfer performance, pressure drop and pressure drop instabilities of flow boiling in mini-channels
    Kuang, B
    Zhang, RH
    Chen, H
    Wang, X
    Shuai, JY
    Kulenovic, R
    Groll, M
    ENERGY AND ENVIRONMENT, VOLS 1 AND 2, 2003, : 696 - 701
  • [22] Flow boiling heat transfer and pressure drop of R-134a in a mini tube: an experimental investigation
    Copetti, Jacqueline B.
    Macagnan, Mario H.
    Zinani, Flavia
    Kunsler, Nicole L. F.
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2011, 35 (04) : 636 - 644
  • [23] An experimental study of flow boiling frictional pressure drop of R134a and evaluation of existing correlations
    Xu, Yu
    Fang, Xiande
    Li, Dingkun
    Li, Guohua
    Yuan, Yuliang
    Xu, Anyi
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2016, 98 : 150 - 163
  • [24] Flow Boiling Pressure Drop of R134a in Microdiameter Tubes: Experimental Results and Assessment of Correlations
    Mahmoud, Mohamed M.
    Karayiannis, Tassos G.
    Kenning, David B. R.
    HEAT TRANSFER ENGINEERING, 2014, 35 (02) : 178 - 192
  • [25] R134a flow boiling heat transfer and pressure drop inside a 3.4 mm ID microfin tube
    Mancin, Simone
    Diani, Andrea
    Rossetto, Luisa
    ATI 2013 - 68TH CONFERENCE OF THE ITALIAN THERMAL MACHINES ENGINEERING ASSOCIATION, 2014, 45 : 608 - 615
  • [26] The effect of heating direction on flow boiling heat transfer of R134a in micro-channels
    Mingchen Xu
    Li Jia
    Chao Dang
    Qi Peng
    Journal of Thermal Science, 2017, 26 : 166 - 174
  • [27] Heat transfer and pressure drop characteristics of R134a flow boiling in the parallel/tandem microchannel heat sinks
    Zhang, Yaxian
    Wang, Jingtao
    Liu, Wei
    Liu, Zhichun
    ENERGY CONVERSION AND MANAGEMENT, 2017, 148 : 1082 - 1095
  • [28] Water flow boiling in a partially modified microgap with shortened micro pin fins
    Yin, Liaofei
    Jiang, Peixue
    Xu, Ruina
    Hu, Haowei
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2020, 155
  • [29] A VISUALIZATION STUDY DURING FLOW BOILING OF R134a IN A HORIZONTAL MICROCHANNEL
    Ali, Rashid
    Palm, Bjorn
    Maqbool, Mohammad H.
    PROCEEDINGS OF THE 8TH INTERNATIONAL CONFERENCE ON NANOCHANNELS, MICROCHANNELS AND MINICHANNELS, 2010, PTS A AND B, 2011, : 85 - 94
  • [30] Experimental investigation on the flow boiling of R134a in a plate heat exchanger with mini-wavy corrugations
    Lao, Wei-chao
    Fang, Yi-dong
    Chen, Qing-hu
    Xu, Lin-jie
    Yang, Hui-nan
    Huang, Yu-qi
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2024, 162 : 53 - 63