Incident contamination lepton doses measured using radiochromic film in radiotherapy

被引:1
|
作者
Butson, MJ
Yu, PKN
Metcalfe, PE
机构
[1] Illawarra Canc Care Ctr, Dept Med Phys, Wollongong, NSW 2500, Australia
[2] City Univ Hong Kong, Dept Phys & Mat Sci, Hong Kong, Peoples R China
关键词
D O I
10.1016/S1350-4487(98)00072-9
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Measurement of lepton contamination is achieved across a radiotherapy photon beam and peripheral doses using radiochromic film. An extrapolation technique is used where several layers are suspended in air to measure incident contamination without the-effects of phantom scatter. Surface dose was measured as 11% of D-max for 6 MV beams at central axis and 9% for 10 MV photons for a 10 x 10 cm field size. Peripheral lepton doses were found to decrease compared to central, however, were still measurable. Peripheral lepton dose was found to increase with field size and was 12% and 15%, 2 cm outside the geometric held edge of a 30 x 30 cm field size at 6 and 10 MV respectively. Radiochromic film is a suitable dosimeter for measurement of lepton contamination absorbed dose to surface layers of skin. (C) 1998 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:605 / 609
页数:5
相关论文
共 50 条
  • [11] Reference dosimetry using radiochromic film
    Girard, Frederic
    Bouchard, Hugo
    Lacroix, Frederic
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2012, 13 (06): : 339 - 353
  • [12] Evaluation of a Magnetic Resonance Image Gated Radiotherapy System Using a Motion Phantom and Radiochromic Film
    Lamb, J.
    Ginn, J.
    O'Connell, D.
    Thomas, D.
    Agazaryan, N.
    Cao, M.
    Yang, Y.
    Low, D.
    MEDICAL PHYSICS, 2016, 43 (06) : 3442 - 3442
  • [13] A protocol for accurate radiochromic film dosimetry using Radiochromic.com
    Mendez, Ignasi
    Jose Rovira-Escutia, Juan
    Casar, Bozidar
    RADIOLOGY AND ONCOLOGY, 2021, 55 (03) : 369 - 378
  • [14] Radiochromic film dosimetry in radiotherapy: a survey of current practice in the United Kingdom
    Palmer, Antony L.
    Nash, David
    BRITISH JOURNAL OF RADIOLOGY, 2024, 97 (1155) : 646 - 651
  • [15] The comparison of doses measured by radiochromic films and semiconductor detector in a 175 MeV proton beam
    Mumot, Marta
    Mytsin, Gennady V.
    Molokanov, Alexander G.
    Malicki, Julian
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2009, 25 (03): : 105 - 110
  • [16] Radiochromic film for individual patient QA in extracranial stereotactic lung radiotherapy
    Kron, T.
    Clements, N.
    Aarons, Y.
    Dunn, L.
    Chesson, B.
    Miller, J.
    Roozen, K.
    Ball, D.
    RADIATION MEASUREMENTS, 2011, 46 (12) : 1920 - 1923
  • [17] Dosimetric validation of a magnetic resonance image gated radiotherapy system using a motion phantom and radiochromic film
    Lamb, James M.
    Ginn, John S.
    O'Connell, Dylan P.
    Agazaryan, Nzhde
    Cao, Minsong
    Thomas, David H.
    Yang, Yingli
    Lazea, Mircea
    Lee, Percy
    Low, Daniel A.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2017, 18 (03): : 163 - 169
  • [18] Multi-dimensional dosimetric verification of stereotactic radiotherapy for uveal melanoma using radiochromic EBT film
    Sturtewagen, Eva
    Fuss, Martina
    Paelinck, Leen
    De Wagter, Carlos
    Georg, Dietmar
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2008, 18 (01): : 27 - 36
  • [19] Dosimetry using a radiochromic film and a mammography phantom
    Gotanda, Tatsuhiro
    Kawaji, Yasuyuki
    Yatake, Hidetoshi
    Imai, Shinya
    Akagawa, Takuya
    Katsuda, Toshizo
    RADIATION PROTECTION DOSIMETRY, 2023, 199 (8-9) : 1007 - 1011
  • [20] Absorbed dose distributions of ruthenium ophthalmic plaques measured in water with radiochromic film
    Hermida-Lopez, M.
    Brualla, L.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S421 - S422