Incident contamination lepton doses measured using radiochromic film in radiotherapy

被引:1
|
作者
Butson, MJ
Yu, PKN
Metcalfe, PE
机构
[1] Illawarra Canc Care Ctr, Dept Med Phys, Wollongong, NSW 2500, Australia
[2] City Univ Hong Kong, Dept Phys & Mat Sci, Hong Kong, Peoples R China
关键词
D O I
10.1016/S1350-4487(98)00072-9
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Measurement of lepton contamination is achieved across a radiotherapy photon beam and peripheral doses using radiochromic film. An extrapolation technique is used where several layers are suspended in air to measure incident contamination without the-effects of phantom scatter. Surface dose was measured as 11% of D-max for 6 MV beams at central axis and 9% for 10 MV photons for a 10 x 10 cm field size. Peripheral lepton doses were found to decrease compared to central, however, were still measurable. Peripheral lepton dose was found to increase with field size and was 12% and 15%, 2 cm outside the geometric held edge of a 30 x 30 cm field size at 6 and 10 MV respectively. Radiochromic film is a suitable dosimeter for measurement of lepton contamination absorbed dose to surface layers of skin. (C) 1998 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:605 / 609
页数:5
相关论文
共 50 条
  • [1] USING A SCANNER TO MEASURE ABSORBED DOSES WITH RADIOCHROMIC FILM DOSIMETERS
    Morgunov, Volodymyr
    Lytovchenko, Serhii
    Chyshkala, Volodymyr
    Didenko, Natalia
    Vynnyk, Valentyn
    EAST EUROPEAN JOURNAL OF PHYSICS, 2022, (01): : 85 - 95
  • [2] Paper based radiochromic film for the detection and measurement of therapeutic radiation doses in radiotherapy: A preliminary study
    Mittal, Apoorva
    Shaw, Ranjay
    Binjola, Ashish
    Natanasabapathi, Gopishankar
    Sharma, Daya Nand
    RADIATION PHYSICS AND CHEMISTRY, 2023, 205
  • [3] Novel Radiochromic Film Dosimeter for Radiotherapy Applications
    Chopra, N.
    Liu, K.
    Beddar, S.
    Schueler, E.
    MEDICAL PHYSICS, 2022, 49 (06) : E326 - E327
  • [4] Radiochromic Film Dosimetry and its Applications in Radiotherapy
    Williams, Matthew
    Metcalfe, Peter
    CONCEPTS AND TRENDS IN MEDICAL RADIATION DOSIMETRY, 2011, 1345 : 75 - +
  • [5] Dependence of radiochromic film response kinetics on fractionated doses
    Ali, I
    Williamson, JF
    Costescu, C
    Dempsey, JF
    APPLIED RADIATION AND ISOTOPES, 2005, 62 (04) : 609 - 617
  • [6] Total skin electron therapy vertical profiles measured using radiochromic film
    Cappelletto, Nicole I. C.
    Shim, Martin G.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (05):
  • [7] Longitudinal radiochromic-film dosimetry for carbonion radiotherapy
    Kanematsu, N.
    Mizuno, H.
    Nakaji, T.
    Yonai, S.
    Matsumoto, S.
    Inaniwa, T.
    RADIOTHERAPY AND ONCOLOGY, 2019, 141 : S82 - S83
  • [8] Radiochromic film as a radiotherapy surface-dose detector
    Butson, MJ
    Mathur, JN
    Metcalfe, PE
    PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (06): : 1073 - 1078
  • [9] Investigation of a Novel Radiochromic Film Material for Radiotherapy Applications
    Gawad, M. Abdel
    Eldib, A.
    Lotfy, S.
    Desouky, O.
    MEDICAL PHYSICS, 2017, 44 (06) : 2934 - 2934
  • [10] Radiochromic film dosimetry of contrast-enhanced radiotherapy (CERT)
    Morris, Kevin N.
    Weil, Michael D.
    Malzbender, Rainer
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (22): : 5915 - 5925