Highly Sensitive Magnetic Field Measurement With Taper-Based In-Line Mach-Zehnder Interferometer and Vernier Effect

被引:20
|
作者
Gu, Sanfeng [1 ]
Feng, Danqi [1 ]
Zhang, Tianheng [1 ]
Deng, Shudan [1 ]
Li, Meng [1 ]
Hu, Yiwen [1 ]
Sun, Wei [2 ]
Deng, Ming [1 ]
机构
[1] Chongqing Univ, Minist Educ, Key Lab Optoelect Technol & Syst, Chongqing 400044, Peoples R China
[2] China Coal Technol & Engn Grp Chongqing Res Inst, Chongqing 400039, Peoples R China
基金
中国国家自然科学基金;
关键词
Optical fiber sensors; Magnetic fields; Interference; Magnetic field measurement; Temperature measurement; Sensitivity; Optical fiber couplers; Fiber-optic sensor; in-line Mach-Zehnder inter- ferometer; magnetic field measurement; optical Vernier effect; PHOTONIC CRYSTAL FIBER; SENSOR;
D O I
10.1109/JLT.2022.3141450
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A taper-based in-line Mach-Zehnder interferometer (MZI) coated with the magnetic fluids (MFs) is designed and experimentally verified for the highly sensitive magnetic field measurement. The effect of waist diameter on the characteristic parameters of transmission modes is numerically analyzed by the finite element method (FEM). The sensing MZI (S-MZI) with a waist diameter of similar to 8.92 mu m is fabricated, in which the multi-mode interference occurs between the fundamental mode (HE11) and cladding modes (HE21 and TM01 modes). The S-MZI has the average sensitivities of 1.180 and 1.305 nm/mT near 1550 nm as the magnetic field increases and decreases in the range of 10.15 similar to 30.44 mT. In order to further improve the measurement sensitivity of the magnetic field, a cascaded MZI (C-MZI) based on the Vernier effect is proposed, which is composed of a reference MZI (R-MZI) without MFs connected in series with the above S-MZI. An evident envelope and shift influenced by the external magnetic field is observed in the transmission spectra of the C-MZI, resulting in the sensitivity being elevated by an amplification factor. The C-MZI shows the average sensitivities of -5.148 and -5.782 nm/mT near 1500 nm, respectively, being similar to 4.77 and 4.83 times of those in the single S-MZI. Therefore, the proposed device may have broad applications in the magnetic field measurement in view of the advantages of high sensitivity, low cost, small volume, and simple fabrication.
引用
收藏
页码:909 / 917
页数:9
相关论文
共 50 条
  • [1] Fiber Taper-Based Mach-Zehnder Interferometer for Ethanol Concentration Measurement
    Liao, Changrui
    Zhu, Feng
    Zhou, Peng
    Wang, Ying
    MICROMACHINES, 2019, 10 (11)
  • [2] In-Line Microfiber-Assisted Mach-Zehnder Interferometer for Microfluidic Highly Sensitive Measurement of Salinity
    Xie, Nanjie
    Zhang, Hao
    Liu, Bo
    Liu, Haifeng
    Liu, Ting
    Wang, Chao
    IEEE SENSORS JOURNAL, 2018, 18 (21) : 8767 - 8772
  • [3] Nonadiabatic fiber taper-based Mach-Zehnder interferometer for refractive index sensing
    Xu, Linlin
    Li, Ying
    Li, Baojun
    APPLIED PHYSICS LETTERS, 2012, 101 (15)
  • [4] Highly Sensitive Strain and Temperature Sensors Based on Vernier Effect in Cascaded Mach-Zehnder Interferometer and Sagnac Interferometer
    Shi, Ruyue
    Chen, Hailiang
    Fan, Xiaoya
    Liu, Chaoyi
    Li, Hongwei
    Gao, Zhigang
    Zhang, Sa
    Gu, Mingqi
    Li, Lida
    Zheng, Yu
    Li, Shuguang
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73 : 1 - 1
  • [5] Fiber in-line magnetic field sensor based on Mach-Zehnder interferometer integrated with magnetic fluid
    雷雪琴
    徐彦超
    于雅婷
    彭保进
    Optoelectronics Letters, 2019, 15 (01) : 43 - 47
  • [6] Fiber in-line magnetic field sensor based on Mach-Zehnder interferometer integrated with magnetic fluid
    Xue-qin Lei
    Yan-chao Xu
    Ya-ting Yu
    Bao-jin Peng
    Optoelectronics Letters, 2019, 15 : 43 - 47
  • [7] Fiber in-line magnetic field sensor based on Mach-Zehnder interferometer integrated with magnetic fluid
    Lei Xue-qin
    Xu Yan-chao
    Yu Ya-ting
    Peng Bao-jin
    OPTOELECTRONICS LETTERS, 2019, 15 (01) : 43 - 47
  • [8] Tapered-open-cavity-based in-line Mach-Zehnder interferometer for highly sensitive axial-strain measurement
    Liu, Chuanxu
    Zhang, Meng
    Zhang, Hui
    Yang, Jiuru
    Shang, Qinghai
    Yang, Xiaotong
    Wang, Shuai
    Ran, Lingling
    OPTICS EXPRESS, 2022, 30 (04) : 6341 - 6354
  • [9] Packaged in-line Mach-Zehnder interferometer for highly sensitive curvature and flexural strain sensing
    Lin, H. S.
    Raji, Y. M.
    Lim, J. H.
    Lim, S. K.
    Mokhtar, M. R.
    Yusoff, Z.
    SENSORS AND ACTUATORS A-PHYSICAL, 2016, 250 : 237 - 242
  • [10] Highly sensitive vibration frequency sensing utilising serial in-line Mach-Zehnder interferometer
    Rodzi N.S.M.
    Mokhtar M.R.
    Optik, 2023, 291