Seismic-induced fire resistance of composite welded beam-to-column joints with concrete-filled tubes

被引:24
作者
Pucinotti, R. [1 ]
Bursi, O. S. [2 ]
Franssen, J-M. [3 ]
Lennon, T. [4 ]
机构
[1] Mediterranean Univ Reggio Calabria, Dept Mat & Mech, Reggio Di Calabria, Italy
[2] Trento Univ, Dept Mech & Struct Engn, Trento, Italy
[3] Univ Liege, Dept Architecture Geol Environm & Construct, Liege, Belgium
[4] Bldg Res Estab Ltd, Garston, England
关键词
Performance-based engineering; Fire; Seismic; Steel-concrete composite beam-to-column joint; Welded connection; Concrete-filled tube; STEEL; PERFORMANCE;
D O I
10.1016/j.firesaf.2011.05.003
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Major earthquakes in urban areas have often been followed by significant fires that cause extensive damage to property. Therefore, a seismic-induced fire is a scenario that should be addressed properly in performance-based engineering. In this paper, numerical and experimental results of welded steel-concrete composite full-strength beam-to-column joints under post-earthquake fires are described. This was part of a European project aimed at developing fundamental data and prequalification design guidelines of ductile and fire-resistant composite beam-to-column joints with concrete-filled tubes. In detail, seismic and fire analyses were used to design moment-resisting frames endowed with the proposed joint typology. A total of six specimens were designed and subjected to both monotonic and cyclic lateral loads. The specimens were subassemblages of beam-to-column joints, and performed well. Since the scope of the project was to promote joint typologies able to survive a seismic-induced fire, some specimens were pre-damaged before being subjected to fire loadings by imposing monotonic loads equivalent to damage levels induced by seismic loadings. Thus, after fire testing, valuable information about the performance of the proposed joint typology was obtained, and the adequacy of the concurrent seismic and fire design was demonstrated. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:335 / 347
页数:13
相关论文
共 45 条
  • [41] The Influence of Key Component Characteristic on the Resistance to Progressive Collapse of Composite Joint With the Concrete-Filled Steel Tubular Column and Steel Beam With Through Bolt-Extended Endplate
    Shi, Yan-Li
    Zheng, Long
    Wang, Wen-Da
    FRONTIERS IN MATERIALS, 2019, 6
  • [42] A novel seawater and sea sand concrete-filled CFRP-carbon steel composite tube column: Seismic behavior and finite element analysis
    Zhang, Yirui
    Wei, Yang
    Li, Bing
    Wang, Gaofei
    Huang, Linjie
    ENGINEERING STRUCTURES, 2022, 270
  • [43] Seismic performance of exterior beam-column joints constructed with engineered cementitious composite: Comparison with ordinary and steel fibre reinforced concrete
    Suryanto, B.
    Tambusay, A.
    Suprobo, P.
    Bregoli, G.
    Aitken, M. W.
    ENGINEERING STRUCTURES, 2022, 250
  • [44] Seismic behavior and design of repairable precast RC beam-concrete-filled square steel tube column joints with energy-dissipating bolts
    Zhang, Yue
    Li, Dongsheng
    JOURNAL OF BUILDING ENGINEERING, 2021, 44 (44):
  • [45] Seismic Resistance Evaluation of Reinforced Concrete (RC) Exterior Beam-Column Joints with and without GFRP under Quasi-static Lateral Cyclic Loading by Adopting Experimental Analysis
    Osman, S. A.
    Yatim, M. Y. M.
    Abd Kader, Asma Nabila Binti
    Amit, Mohd Razmi Mohd
    JURNAL KEJURUTERAAN, 2022, 34 (06): : 1175 - 1184