Seismic-induced fire resistance of composite welded beam-to-column joints with concrete-filled tubes

被引:24
作者
Pucinotti, R. [1 ]
Bursi, O. S. [2 ]
Franssen, J-M. [3 ]
Lennon, T. [4 ]
机构
[1] Mediterranean Univ Reggio Calabria, Dept Mat & Mech, Reggio Di Calabria, Italy
[2] Trento Univ, Dept Mech & Struct Engn, Trento, Italy
[3] Univ Liege, Dept Architecture Geol Environm & Construct, Liege, Belgium
[4] Bldg Res Estab Ltd, Garston, England
关键词
Performance-based engineering; Fire; Seismic; Steel-concrete composite beam-to-column joint; Welded connection; Concrete-filled tube; STEEL; PERFORMANCE;
D O I
10.1016/j.firesaf.2011.05.003
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Major earthquakes in urban areas have often been followed by significant fires that cause extensive damage to property. Therefore, a seismic-induced fire is a scenario that should be addressed properly in performance-based engineering. In this paper, numerical and experimental results of welded steel-concrete composite full-strength beam-to-column joints under post-earthquake fires are described. This was part of a European project aimed at developing fundamental data and prequalification design guidelines of ductile and fire-resistant composite beam-to-column joints with concrete-filled tubes. In detail, seismic and fire analyses were used to design moment-resisting frames endowed with the proposed joint typology. A total of six specimens were designed and subjected to both monotonic and cyclic lateral loads. The specimens were subassemblages of beam-to-column joints, and performed well. Since the scope of the project was to promote joint typologies able to survive a seismic-induced fire, some specimens were pre-damaged before being subjected to fire loadings by imposing monotonic loads equivalent to damage levels induced by seismic loadings. Thus, after fire testing, valuable information about the performance of the proposed joint typology was obtained, and the adequacy of the concurrent seismic and fire design was demonstrated. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:335 / 347
页数:13
相关论文
共 45 条
  • [31] Seismic behavior of corrugated double-skin composite wall (DSCW) with concrete-filled steel tubes: Experimental investigation
    Zhou, Ji
    Chen, Zongping
    Liao, Haoyu
    Tang, Jiyu
    ENGINEERING STRUCTURES, 2022, 252
  • [32] Experimental Study on Seismic Behavior of Plane and Spatial Concrete Beam-column Joints After Exposure to Fire
    Lu Z.
    Chen Y.
    Li L.
    Liu X.
    Wei K.
    Tongji Daxue Xuebao/Journal of Tongji University, 2020, 48 (03): : 340 - 348
  • [33] Seismic behavior of composite shear walls with boundary columns using rectangular and U-shaped concrete-filled steel tubes
    Wang, Guo-Jue
    Jiang, Shi-Yong
    Hou, Quan-Sheng
    Zhu, Li-Min
    Tian, Chun-Yu
    JOURNAL OF BUILDING ENGINEERING, 2023, 73
  • [34] Seismic damage assessment of steel reinforced recycled concrete column-steel beam composite frame joints
    Dong, Jing
    Ma, Hui
    Zhang, Nina
    Liu, Yunhe
    Mao, Zhaowei
    EARTHQUAKES AND STRUCTURES, 2018, 14 (01) : 73 - 84
  • [35] Axial compression behavior of reinforced concrete beam to square thin-walled concrete-filled steel tube column joints stiffened by internal diaphragms
    Gan, Dan
    Zhao, Zhongxiang
    Zhou, Zheng
    Zhou, Xuhong
    STRUCTURAL CONCRETE, 2023, 24 (03) : 3674 - 3691
  • [36] NONLINEAR FEM ANALYSIS AND EXPERIMENT RESEARCH ON MECHANICAL BEHAVIOR OF BEAM-COLUMN JOINT OF CONCRETE-FILLED TUBE COMPOSITE MATERIAL
    Zhou, T.
    Wang, J. G.
    Wan, H. Y.
    ADVANCES IN HETEROGENEOUS MATERIAL MECHANICS 2011, 2011, : 796 - 799
  • [37] Assessment and Design Procedure for the Seismic Retrofit of Reinforced Concrete Beam-Column Joints using FRP Composite Materials
    Akguzel, Umut
    Pampanin, Stefano
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2012, 16 (01) : 21 - 34
  • [38] Seismic behavior of composite interior joints of prefabricated H-shaped steel reinforced concrete column - steel beam
    Wu, Chenglong
    Liu, Jiming
    Tan, Wenya
    Wang, Pengfei
    STRUCTURES, 2020, 23 : 558 - 572
  • [39] Fire resistance and flexural load capacity of beam-column welded-bolted hybrid connection joints under post-earthquake fire
    Xu, Jixiang
    Chong, Xinda
    Han, Jianping
    STRUCTURES, 2024, 62
  • [40] Static strength design of local thickened plate joints between multi-cell concrete-filled steel tubular column and steel beam
    Sun, Hao-Jun
    Liu, Ya-Zhou
    Hou, Yan-Guo
    Bai, Wen-Hua
    Liu, Guang-Hui
    Wang, Xiong
    Guo, Yan-Lin
    JOURNAL OF BUILDING ENGINEERING, 2023, 80