Radiation dose management for pediatric cardiac computed tomography: a report from the Image Gently 'Have-A-Heart' campaign

被引:39
作者
Rigsby, Cynthia K. [1 ,2 ]
McKenney, Sarah E. [3 ]
Hill, Kevin D. [4 ]
Chelliah, Anjali [5 ,6 ]
Einstein, Andrew J. [6 ,7 ,8 ]
Han, B. Kelly [9 ]
Robinson, Joshua D. [10 ,11 ]
Sammet, Christina L. [1 ,2 ]
Slesnick, Timothy C. [12 ]
Frush, Donald P. [13 ]
机构
[1] Northwestern Univ, Ann & Robert H Lurie Childrens Hosp Chicago, Feinberg Sch Med, Dept Radiol,Dept Med Imaging 9, 225 E Chicago Ave, Chicago, IL 60611 USA
[2] Northwestern Univ, Dept Pediat, Ann & Robert H Lurie Childrens Hosp Chicago, Feinberg Sch Med,Dept Med Imaging 9, 225 E Chicago Ave, Chicago, IL 60611 USA
[3] Childrens Natl Med Ctr, Div Diagnost Imaging & Radiol, Washington, DC 20010 USA
[4] Duke Univ, Med Ctr, Dept Pediat, Durham, NC 27710 USA
[5] Columbia Univ, Med Ctr, Div Pediat Cardiol, New York, NY USA
[6] New York Presbyterian Hosp, New York, NY USA
[7] Columbia Univ, Dept Med, Div Cardiol, New York, NY USA
[8] Columbia Univ, Dept Radiol, Div Cardiol, New York, NY USA
[9] Childrens Hosp & Clin Minnesota, Childrens Heart Clin, Dept Pediat, Minneapolis, MN USA
[10] Northwestern Univ, Dept Pediat, Ann & Robert H Lurie Childrens Hosp Chicago, Div Pediat Cardiol,Feinberg Sch Med, Chicago, IL 60611 USA
[11] Northwestern Univ, Ann & Robert H Lurie Childrens Hosp Chicago, Feinberg Sch Med, Div Pediat Cardiol,Dept Radiol, Chicago, IL 60611 USA
[12] Emory Univ, Sch Med, Dept Pediat, Childrens Healthcare Atlanta, Atlanta, GA USA
[13] Duke Univ, Med Ctr, Dept Radiol, Durham, NC 27710 USA
关键词
Computed tomography; Children; Congenital heart disease; Heart; Radiation safety; CORONARY CT ANGIOGRAPHY; DUAL-SOURCE CT; CARDIOVASCULAR MAGNETIC-RESONANCE; EXPERT CONSENSUS DOCUMENT; POTENTIAL CANCER-RISKS; ITERATIVE RECONSTRUCTION; YOUNG-CHILDREN; CONTRAST-ENHANCEMENT; EMERGENCY-DEPARTMENT; DIAGNOSTIC-ACCURACY;
D O I
10.1007/s00247-017-3991-x
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Children with congenital or acquired heart disease can be exposed to relatively high lifetime cumulative doses of ionizing radiation from necessary medical imaging procedures including radiography, fluoroscopic procedures including diagnostic and interventional cardiac catheterizations, electrophysiology examinations, cardiac computed tomography (CT) studies, and nuclear cardiology examinations. Despite the clinical necessity of these imaging studies, the related ionizing radiation exposure could pose an increased lifetime attributable cancer risk. The Image Gently "Have-A-Heart" campaign is promoting the appropriate use of medical imaging studies in children with congenital or acquired heart disease while minimizing radiation exposure. The focus of this manuscript is to provide a comprehensive review of radiation dose management and CT performance in children with congenital or acquired heart disease.
引用
收藏
页码:5 / 20
页数:16
相关论文
共 50 条
  • [41] Image quality and radiation dose of dual-source CT cardiac angiography using prospective ECG-triggering technique in pediatric patients with congenital heart disease
    Liu, Ying
    Li, Jian
    Zhao, Hongliang
    Jia, Yan
    Ren, Jing
    Xu, Jian
    Hao, Yuewen
    Zheng, Minwen
    JOURNAL OF CARDIOTHORACIC SURGERY, 2016, 11
  • [42] Radiation Dose and Image Quality in Pediatric Cardiac Computed Tomography: A Comparison Between Sequential and Third-Generation Dual-Source High-Pitch Spiral Techniques
    Huiliang Koh
    Ching Ching Ong
    Yun Song Choo
    Chong Ri Liang
    Grace Hui Zhen Tan
    Terence Chee Wen Lim
    Swee Chye Quek
    Shankar Sriram
    Lynette Li San Teo
    Pediatric Cardiology, 2016, 37 : 1397 - 1403
  • [43] Pediatric chest computed tomography at 100 kVp with tin filtration: comparison of image quality with 70-kVp imaging at comparable radiation dose
    Sophie Vivier
    Valérie Deken
    Younes Arous
    Jean-Baptiste Faivre
    Alain Duhamel
    Antoine Deschildre
    Thomas Flohr
    Jacques Remy
    Martine Remy-Jardin
    Pediatric Radiology, 2020, 50 : 188 - 198
  • [44] Image quality and radiation dose in 256-slice cardiac computed tomography: Comparison of prospective versus retrospective image acquisition protocols
    Hosch, Waldemar
    Heye, Tobias
    Schulz, Felix
    Lehrke, Stephanie
    Schlieter, Martin
    Giannitsis, Evangelos
    Kauczor, Hans-Ulrich
    Katus, Hugo A.
    Korosoglou, Grigorios
    EUROPEAN JOURNAL OF RADIOLOGY, 2011, 80 (01) : 127 - 135
  • [45] Postoperative computed tomography imaging of pediatric patients with craniosynostosis: radiation dose and image quality comparison between multi-slice computed tomography and O-arm cone-beam computed tomography
    Touko Kaasalainen
    Ville Männistö
    Teemu Mäkelä
    Juho Suojanen
    Antton Nuorala
    Arja Heliövaara
    Junnu Leikola
    Pediatric Radiology, 2023, 53 : 1704 - 1712
  • [46] Optimizing image quality and minimizing radiation dose in pediatric abdominal multiphase contrast-enhanced computed tomography: a study on CARE kV and CARE Dose 4D
    Tian, Xinyu
    Chang, Zhenjiang
    Dilixiati, Subinuer
    Haimiti, Yilisuyaer
    Wang, Shui
    Sun, Jihang
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (02) : 1985 - 1993
  • [47] Managing Radiation Dose from Thoracic Multidetector Computed Tomography in Pediatric Patients: Background, Current Issues, and Recommendations
    MacDougall, Robert D.
    Strauss, Keith J.
    Lee, Edward Y.
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2013, 51 (04) : 743 - +
  • [48] Image quality and radiation dose of brain computed tomography in children: effects of decreasing tube voltage from 120 kVp to 80 kVp
    Park, Ji Eun
    Choi, Young Hun
    Cheon, Jung-Eun
    Kim, Woo Sun
    Kim, In-One
    Cho, Hyun Suk
    Ryu, Young Jin
    Kim, Yu Jin
    PEDIATRIC RADIOLOGY, 2017, 47 (06) : 710 - 717
  • [49] Image quality and radiation dose of brain computed tomography in children: effects of decreasing tube voltage from 120 kVp to 80 kVp
    Ji Eun Park
    Young Hun Choi
    Jung-Eun Cheon
    Woo Sun Kim
    In-One Kim
    Hyun Suk Cho
    Young Jin Ryu
    Yu Jin Kim
    Pediatric Radiology, 2017, 47 : 710 - 717
  • [50] High-Pitch Computed Tomography of the Lung in Pediatric Patients: An Intraindividual Comparison of Image Quality and Radiation Dose to Conventional 64-MDCT
    Tsiflikas, I.
    Thomas, C.
    Ketelsen, D.
    Seitz, G.
    Warmann, S.
    Claussen, C. D.
    Schaefer, J. F.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2014, 186 (06): : 585 - 590