Radiation dose management for pediatric cardiac computed tomography: a report from the Image Gently 'Have-A-Heart' campaign

被引:39
作者
Rigsby, Cynthia K. [1 ,2 ]
McKenney, Sarah E. [3 ]
Hill, Kevin D. [4 ]
Chelliah, Anjali [5 ,6 ]
Einstein, Andrew J. [6 ,7 ,8 ]
Han, B. Kelly [9 ]
Robinson, Joshua D. [10 ,11 ]
Sammet, Christina L. [1 ,2 ]
Slesnick, Timothy C. [12 ]
Frush, Donald P. [13 ]
机构
[1] Northwestern Univ, Ann & Robert H Lurie Childrens Hosp Chicago, Feinberg Sch Med, Dept Radiol,Dept Med Imaging 9, 225 E Chicago Ave, Chicago, IL 60611 USA
[2] Northwestern Univ, Dept Pediat, Ann & Robert H Lurie Childrens Hosp Chicago, Feinberg Sch Med,Dept Med Imaging 9, 225 E Chicago Ave, Chicago, IL 60611 USA
[3] Childrens Natl Med Ctr, Div Diagnost Imaging & Radiol, Washington, DC 20010 USA
[4] Duke Univ, Med Ctr, Dept Pediat, Durham, NC 27710 USA
[5] Columbia Univ, Med Ctr, Div Pediat Cardiol, New York, NY USA
[6] New York Presbyterian Hosp, New York, NY USA
[7] Columbia Univ, Dept Med, Div Cardiol, New York, NY USA
[8] Columbia Univ, Dept Radiol, Div Cardiol, New York, NY USA
[9] Childrens Hosp & Clin Minnesota, Childrens Heart Clin, Dept Pediat, Minneapolis, MN USA
[10] Northwestern Univ, Dept Pediat, Ann & Robert H Lurie Childrens Hosp Chicago, Div Pediat Cardiol,Feinberg Sch Med, Chicago, IL 60611 USA
[11] Northwestern Univ, Ann & Robert H Lurie Childrens Hosp Chicago, Feinberg Sch Med, Div Pediat Cardiol,Dept Radiol, Chicago, IL 60611 USA
[12] Emory Univ, Sch Med, Dept Pediat, Childrens Healthcare Atlanta, Atlanta, GA USA
[13] Duke Univ, Med Ctr, Dept Radiol, Durham, NC 27710 USA
关键词
Computed tomography; Children; Congenital heart disease; Heart; Radiation safety; CORONARY CT ANGIOGRAPHY; DUAL-SOURCE CT; CARDIOVASCULAR MAGNETIC-RESONANCE; EXPERT CONSENSUS DOCUMENT; POTENTIAL CANCER-RISKS; ITERATIVE RECONSTRUCTION; YOUNG-CHILDREN; CONTRAST-ENHANCEMENT; EMERGENCY-DEPARTMENT; DIAGNOSTIC-ACCURACY;
D O I
10.1007/s00247-017-3991-x
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Children with congenital or acquired heart disease can be exposed to relatively high lifetime cumulative doses of ionizing radiation from necessary medical imaging procedures including radiography, fluoroscopic procedures including diagnostic and interventional cardiac catheterizations, electrophysiology examinations, cardiac computed tomography (CT) studies, and nuclear cardiology examinations. Despite the clinical necessity of these imaging studies, the related ionizing radiation exposure could pose an increased lifetime attributable cancer risk. The Image Gently "Have-A-Heart" campaign is promoting the appropriate use of medical imaging studies in children with congenital or acquired heart disease while minimizing radiation exposure. The focus of this manuscript is to provide a comprehensive review of radiation dose management and CT performance in children with congenital or acquired heart disease.
引用
收藏
页码:5 / 20
页数:16
相关论文
共 50 条
  • [21] Helical prospective ECG-gating in cardiac computed tomography: radiation dose and image quality
    DeFrance, Tony
    Dubois, Eric
    Gebow, Dan
    Ramirez, Alex
    Wolf, Florian
    Feuchtner, Gudrun M.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2010, 26 (01) : 99 - 107
  • [22] Radiation Dose and Image Quality in Pediatric Cardiac Computed Tomography: A Comparison Between Sequential and Third-Generation Dual-Source High-Pitch Spiral Techniques
    Koh, Huiliang
    Ong, Ching Ching
    Choo, Yun Song
    Liang, Chong Ri
    Tan, Grace Hui Zhen
    Lim, Terence Chee Wen
    Quek, Swee Chye
    Sriram, Shankar
    San Teo, Lynette Li
    PEDIATRIC CARDIOLOGY, 2016, 37 (08) : 1397 - 1403
  • [23] Dual-source cardiac computed tomography angiography (CCTA) in the follow-up of cardiac transplant: comparison of image quality and radiation dose using three different imaging protocols
    Beitzke, D.
    Berger-Kulemann, V.
    Schoepf, V.
    Unterhumer, S.
    Spitzer, E.
    Feuchtner, G. M.
    Gyoengyoesi, M.
    Uyanik-Uenal, K.
    Zuckermann, A.
    Loewe, C.
    Wolf, F.
    EUROPEAN RADIOLOGY, 2015, 25 (08) : 2310 - 2317
  • [24] Radiation Dose from Computed Tomography Scans for Korean Pediatric and Adult Patients
    Won, Tristan
    Lee, Ae-Kyoung
    Choi, Hyung-do
    Lee, Choonsik
    JOURNAL OF RADIATION PROTECTION AND RESEARCH, 2021, 46 (03): : 98 - 105
  • [25] Image Gently Vendor Summit: Working Together for Better Estimates of Pediatric Radiation Dose from CT
    Strauss, Keith J.
    Goske, Marilyn J.
    Frush, Donald P.
    Butler, Priscilla F.
    Morrison, Gregory
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (05) : 1169 - 1175
  • [26] Radiation dose and image quality of 70 kVp functional cardiovascular computed tomography imaging in congenital heart disease
    Lesser, Andrew M.
    Newell, Marc C.
    Samara, Michael A.
    Gornick, Charles
    Grant, Katharine
    Garberich, Ross
    Han, B. Kelly
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2016, 10 (02) : 173 - 178
  • [27] The impact of pediatric-specific dose modulation curves on radiation dose and image quality in head computed tomography
    Joana Santos
    Shane Foley
    Graciano Paulo
    Mark F. McEntee
    Louise Rainford
    Pediatric Radiology, 2015, 45 : 1814 - 1822
  • [28] The impact of pediatric-specific dose modulation curves on radiation dose and image quality in head computed tomography
    Santos, Joana
    Foley, Shane
    Paulo, Graciano
    McEntee, Mark F.
    Rainford, Louise
    PEDIATRIC RADIOLOGY, 2015, 45 (12) : 1814 - 1822
  • [29] Radiation Dose and Image Quality of Prospective Triggering With Dual-Source Cardiac Computed Tomography
    Blankstein, Ron
    Shah, Amar
    Pale, Rodrigo
    Abbara, Suhny
    Bezerra, Hiram
    Bolen, Michael
    Mamuya, Wilfred S.
    Hoffmann, Udo
    Brady, Thomas J.
    Cury, Ricardo C.
    AMERICAN JOURNAL OF CARDIOLOGY, 2009, 103 (08) : 1168 - 1173
  • [30] Helical prospective ECG-gating in cardiac computed tomography: radiation dose and image quality
    Tony DeFrance
    Eric Dubois
    Dan Gebow
    Alex Ramirez
    Florian Wolf
    Gudrun M. Feuchtner