High quality standards for a large-scale prospective population-based observational cohort: Constances

被引:51
作者
Ruiz, Fabrice [1 ]
Goldberg, Marcel [2 ]
Lemonnier, Sylvie [2 ]
Ozguler, Anna [2 ]
Boos, Evelyne [1 ]
Brigand, Alain [3 ]
Giraud, Violaine [4 ]
Perez, Thierry [5 ,6 ]
Roche, Nicolas [7 ,8 ]
Zins, Marie [2 ]
机构
[1] CLINSEARCH, 110 Ave Pierre Brossolette, F-92240 Malakoff, France
[2] INSERM, UVSQ Cohortes Epidemiol Populat, UMS 011, 16 Ave Paul Vaillant Couturier, F-94807 Villejuif, France
[3] Ctr Examens St Angouleme, 5 Rue Croix Lanauve, F-16024 Angouleme, France
[4] Hop Ambroise Pare, AP HP, Serv Pneumol & Oncol Thorac, Boulogne, France
[5] CHU Lille, Hop Calmette, Serv Pneumol, F-59000 Lille, France
[6] CHU Lille, Hop Calmette, Serv EFR, F-59000 Lille, France
[7] Univ Paris 05, EA2511, 27 Rue Fg St Jacques, F-75014 Paris, France
[8] Hop Cochin, Serv Pneumol, 27 Rue Fg St Jacques, F-75014 Paris, France
关键词
Cohort study; Epidemiological methods; Measurement tool development; Methodology; Respiratory; SPIROMETRY; ASSURANCE;
D O I
10.1186/s12889-016-3439-5
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Background: Long-term multicentre studies are subject to numerous factors that may affect the integrity of their conclusions. Quality control and standardization of data collection are crucial to minimise the biases induced by these factors. Nevertheless, tools implemented to manage biases are rarely described in publications about population-based cohorts. This report aims to describe the processes implemented to control biases in the Constances cohort taking lung function results as an example. Methods: Constances is a general-purpose population-based cohort of 200,000 participants. Volunteers attend physical examinations at baseline and then every 5 years at selected study sites. Medical device specifications and measurement methods have to comply with Standard Operating Procedures developed by experts. Protocol deviations are assessed by on-site inspections and database controls. In February 2016, more than 94,000 participants yielding around 30 million readings from physical exams, had been covered by our quality program. Results: Participating centres accepted to revise their practices in accordance with the study research specifications. Distributors of medical devices were asked to comply with international guidelines and Constances requirements. Close monitoring enhanced the quality of measurements and recordings of the physical exams. Regarding lung function testing, spirometry acceptability rates per operator doubled in some sites within a few months and global repeatability reached 96.7 % for 29,772 acceptable maneuvers. Conclusions: Despite Constances volunteers being followed in multiple sites with heterogeneous materials, the investment of significant resources to set up and maintain a continuous quality management process has proved effective in preventing drifts and improving accuracy of collected data.
引用
收藏
页数:10
相关论文
共 12 条
[1]   Detection of Outliers Due to Participants' Non-Adherence to Protocol in a Longitudinal Study of Cognitive Decline [J].
Dugravot, Aline ;
Sabia, Severine ;
Shipley, Martin J. ;
Welch, Catherine ;
Kivimaki, Mika ;
Singh-Manoux, Archana .
PLOS ONE, 2015, 10 (07)
[2]   Repeatability of spirometry in 18,000 adult patients [J].
Enright, PL ;
Beck, KC ;
Sherrill, DL .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2004, 169 (02) :235-238
[3]   Interviewer variability in anthropometric measurements and estimates of body composition [J].
KlipsteinGrobusch, K ;
Georg, T ;
Boeing, H .
INTERNATIONAL JOURNAL OF EPIDEMIOLOGY, 1997, 26 :S174-S180
[4]   Technical and functional assessment of 10 office spirometers - A multicenter comparative study [J].
Liistro, Giuseppe ;
Vanwelde, Carl ;
Vincken, Walter ;
Vandevoorde, Jan ;
Verleden, Geert ;
Buffels, Johan .
CHEST, 2006, 130 (03) :657-665
[5]   Standardisation of spirometry [J].
Miller, MR ;
Hankinson, J ;
Brusasco, V ;
Burgos, F ;
Casaburi, R ;
Coates, A ;
Crapo, R ;
Enright, P ;
van der Grinten, CPM ;
Gustafsson, P ;
Jensen, R ;
Johnson, DC ;
MacIntyre, N ;
McKay, R ;
Navajas, D ;
Pedersen, OF ;
Pellegrino, R ;
Viegi, G ;
Wanger, J .
EUROPEAN RESPIRATORY JOURNAL, 2005, 26 (02) :319-338
[6]   Evaluation of Data Entry Errors and Data Changes to an Electronic Data Capture Clinical Trial Database [J].
Mitchel, Jules T. ;
Kim, Yong Joong ;
Choi, Joonhyuk ;
Park, Glen ;
Cappi, Silvana ;
Horn, David ;
Kist, Morgan ;
D'Agostino, Ralph B., Jr. .
DRUG INFORMATION JOURNAL, 2011, 45 (04) :421-430
[7]  
Pigeot Iris, HDB EPIDEMIOLOGY WOL, DOI [10.1007/978-0-387-09834-0, DOI 10.1007/978-0-387-09834-0]
[8]   LUNG-VOLUMES AND FORCED VENTILATORY FLOWS - REPORT WORKING PARTY STANDARDIZATION OF LUNG-FUNCTION TESTS EUROPEAN-COMMUNITY FOR STEEL AND COAL - OFFICIAL STATEMENT OF THE EUROPEAN RESPIRATORY SOCIETY [J].
QUANJER, PH ;
TAMMELING, GJ ;
COTES, JE ;
PEDERSEN, OF ;
PESLIN, R ;
YERNAULT, JC .
EUROPEAN RESPIRATORY JOURNAL, 1993, 6 :5-40
[9]  
Skloot GS, 2010, RESP CARE, V55, P873
[10]   Quality Assurance of Spirometry in a Population-Based Study - Predictors of Good Outcome in Spirometry Testing [J].
Tan, Wan C. ;
Bourbeau, Jean ;
O'Donnell, Denis ;
Aaron, Shawn ;
Maltais, Francois ;
Marciniuk, Darcy ;
Hernandez, Paul ;
Cowie, Robert ;
Chapman, Kenneth ;
Buist, A. Sonia ;
Sin, Don ;
Fitzgerald, J. Mark .
COPD-JOURNAL OF CHRONIC OBSTRUCTIVE PULMONARY DISEASE, 2014, 11 (02) :143-151