Measurement of small displacement based on surface plasmon resonance heterodyne interferometry

被引:27
|
作者
Lin, Jiun-You [1 ]
Chen, Kun-Huang [2 ]
Chen, Jing-Heng [3 ]
机构
[1] Natl Changhua Univ Educ, Dept Mechatron Engn, Changhua 50074, Taiwan
[2] Feng Chia Univ, Dept Elect Engn, Taichung 40724, Taiwan
[3] Feng Chia Univ, Dept Photon, Taichung 40724, Taiwan
关键词
Small displacement; Surface plasmon resonance; Heterodyne interferometry; Common-path configuration; NONLINEARITY; SYSTEM; BEAM;
D O I
10.1016/j.optlaseng.2011.03.005
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
This paper proposes an optical method for measuring small displacements using the surface plasmon resonance (SPR) heterodyne interferometry. A heterodyne light beam reflected by a mirror passes through a hemisphere glass and then enters into a surface plasmon resonance apparatus at the resonant angle. A small displacement of the mirror will introduce a phase-difference variation between p- and s-polarizations of the light emerging from the SPR apparatus. The phase-difference variation can be precisely measured with the heterodyne interferometric technique, and the associated displacement can be estimated. The feasibility of this method was verified by experiment, and the displacement measurement resolution of about 1.4 nm over a traveling range of 6 pm was achieved. Our method of measurement has the merits of both common-path interferometry and heterodyne interferometry. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:811 / 815
页数:5
相关论文
共 50 条
  • [21] Development of an angular displacement measurement technique through birefringence heterodyne interferometry
    Hsieh, Hung-Lin
    Lee, Ju-Yi
    Chen, Lin-Yu
    Yang, Yang
    OPTICS EXPRESS, 2016, 24 (07): : 6802 - 6813
  • [22] A Birefringent-Refraction Transducer for Measuring Angular Displacement Based on Heterodyne Interferometry
    Twu, Ruey-Ching
    Wang, Ching-Shing
    APPLIED SCIENCES-BASEL, 2016, 6 (08):
  • [23] A new application of optical fiber surface plasmon resonance for micro-displacement measurement
    Wei, Yong
    Wu, Ping
    Zhang, Yonghui
    Liu, Chunlan
    Liu, Lu
    Zhu, Zongda
    Hu, Jiangxi
    SENSORS AND ACTUATORS A-PHYSICAL, 2019, 285 : 216 - 223
  • [24] Development of Phase Detection Schemes Based on Surface Plasmon Resonance Using Interferometry
    Kashif, Muhammad
    Bakar, Ahmad Ashrif A.
    Arsad, Norhana
    Shaari, Sahbudin
    SENSORS, 2014, 14 (09): : 15914 - 15938
  • [25] Performance Analysis of Non-Interferometry Based Surface Plasmon Resonance Microscopes
    Tontarawongsa, Sorawit
    Visitsattapongse, Sarinporn
    Pechprasarn, Suejit
    SENSORS, 2021, 21 (15)
  • [26] Surface plasmon resonance interferometry for biological and chemical sensing
    Nikitin, PI
    Beloglazov, AA
    Kochergin, VE
    Valeiko, MV
    Ksenevich, TI
    SENSORS AND ACTUATORS B-CHEMICAL, 1999, 54 (1-2): : 43 - 50
  • [27] Measurement uncertainty in analytical studies based on surface plasmon resonance
    Boltovets, Praskovia M.
    Snopok, Boris A.
    TALANTA, 2009, 80 (02) : 466 - 472
  • [28] Young's modulus measurement based on surface plasmon resonance
    Lotfalian, Ali
    Jandaghian, Ali
    Saghafifar, Hossein
    Mohajerani, Ezzedin
    OPTICS AND LASER TECHNOLOGY, 2017, 94 : 248 - 252
  • [29] Rapid detection of urinary polyomavirus BK by heterodyne-based surface plasmon resonance biosensor
    Su, Li-Chen
    Tian, Ya-Chung
    Chang, Ying-Feng
    Chou, Chien
    Lai, Chao-Sung
    JOURNAL OF BIOMEDICAL OPTICS, 2014, 19 (01)
  • [30] Application of heterodyne interferometry for the full-field surface shape measurement
    Józwicki, R
    Tkaczyk, T
    12TH CZECH-SLOVAK-POLISH OPTICAL CONFERENCE ON WAVE AND QUANTUM ASPECTS OF CONTEMPORARY OPTICS, 2001, 4356 : 182 - 186