Measurement of small displacement based on surface plasmon resonance heterodyne interferometry

被引:27
|
作者
Lin, Jiun-You [1 ]
Chen, Kun-Huang [2 ]
Chen, Jing-Heng [3 ]
机构
[1] Natl Changhua Univ Educ, Dept Mechatron Engn, Changhua 50074, Taiwan
[2] Feng Chia Univ, Dept Elect Engn, Taichung 40724, Taiwan
[3] Feng Chia Univ, Dept Photon, Taichung 40724, Taiwan
关键词
Small displacement; Surface plasmon resonance; Heterodyne interferometry; Common-path configuration; NONLINEARITY; SYSTEM; BEAM;
D O I
10.1016/j.optlaseng.2011.03.005
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
This paper proposes an optical method for measuring small displacements using the surface plasmon resonance (SPR) heterodyne interferometry. A heterodyne light beam reflected by a mirror passes through a hemisphere glass and then enters into a surface plasmon resonance apparatus at the resonant angle. A small displacement of the mirror will introduce a phase-difference variation between p- and s-polarizations of the light emerging from the SPR apparatus. The phase-difference variation can be precisely measured with the heterodyne interferometric technique, and the associated displacement can be estimated. The feasibility of this method was verified by experiment, and the displacement measurement resolution of about 1.4 nm over a traveling range of 6 pm was achieved. Our method of measurement has the merits of both common-path interferometry and heterodyne interferometry. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:811 / 815
页数:5
相关论文
共 50 条
  • [1] Measurement of the concentration of a solution with surface plasmon resonance heterodyne interferometry
    Chen, KH
    Hsu, CC
    Su, DC
    OPTICAL ENGINEERING, 2003, 42 (07) : 1884 - 1887
  • [2] Design of a small-displacement sensing system based on the surface plasmon resonance technology in heterodyne interferometry
    Wang, Shinn-Fwu
    Yang, Wayne
    Liu, An-Li
    Kao, Fu-Hsi
    Lay, Shyh-Rong
    2012 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2012, : 1391 - 1394
  • [3] Experimental Evaluation of a Small-displacement Sensing System Based on the Surface Plasmon Resonance Technology in Heterodyne Interferometry
    Wang, Shinn-Fwu
    Chen, Chi-Tun
    Kao, Fu-Hsi
    Chu, Yi
    Lay, Shyh-Rong
    Liao, Yu-Pin
    Lin, Liuh-Chii
    Liu, An-Li
    APPLIED SCIENCE AND PRECISION ENGINEERING INNOVATION, PTS 1 AND 2, 2014, 479-480 : 682 - 686
  • [4] Angle measurement using surface-plasmon-resonance heterodyne interferometry: a new method
    Guo, JH
    Zhu, ZM
    Deng, WM
    Shen, S
    OPTICAL ENGINEERING, 1998, 37 (11) : 2998 - 3001
  • [5] Measuring physical parameters with surface plasmon resonance heterodyne interferometry
    Chen, Kun-Huang
    Lin, Jiun-You
    Chen, Jing-Heng
    OPTIK, 2009, 120 (01): : 29 - 34
  • [6] Surface plasmon resonance biosensor using heterodyne interferometry
    Joe, SF
    Wu, CM
    Chang, LB
    Hsieh, LZ
    ADVANCED SENSOR SYSTEMS AND APPLICATIONS II PT 1AND 2, 2004, 5634 : 166 - 173
  • [7] A Small-Displacement Sensor Using Total Internal Reflection Theory and Surface Plasmon Resonance Technology for Heterodyne Interferometry
    Wang, Shinn-Fwu
    SENSORS, 2009, 9 (04): : 2498 - 2510
  • [8] Surface plasmon resonance heterodyne interferometry from measuring physical parameters
    Su, DC
    Chen, JH
    Chen, KH
    Lin, JY
    OPTICAL METROLOGY IN PRODUCTION ENGINEERING, 2004, 5457 : 566 - 573
  • [9] High-sensitivity sensor based on surface plasmon resonance and heterodyne interferometry
    Wu, CM
    Jian, ZC
    Joe, SF
    Chang, LB
    SENSORS AND ACTUATORS B-CHEMICAL, 2003, 92 (1-2): : 133 - 136
  • [10] Measurement of refractive index variation of liquids by surface plasmon resonance and wavelength-modulated heterodyne interferometry
    Lee, Ju-Yi