A Haemodynamic Study during OPCAB Surgery Using a New Multi-Suction Cardiac Positioner

被引:4
作者
Abicht, J. -M. [1 ]
Bauer, A. [1 ]
Christ, F. [1 ]
Vicol, C. [2 ]
机构
[1] Univ Munich, Dept Anaesthesiol, D-81377 Munich, Germany
[2] Univ Munich, Dept Cardiac Surg, D-81377 Munich, Germany
关键词
cardiovascular surgery; coronary bypass surgery; OPCAB; CORONARY-ARTERY-BYPASS; OFF-PUMP; ON-PUMP; MECHANICAL STABILIZATION; HEART; MORTALITY; EXPOSURE; METAANALYSIS; POSTERIOR; BRANCHES;
D O I
10.1055/s-0030-1250479
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Displacement of the heart is necessary to expose the target vessel for distal anastomosis to achieve successful multivessel off-pump coronary artery bypass (OPCAB) grafting. In addition to complete revascularisation of the heart, a main challenge during the operation is to maintain haemodynamic stability during this procedure. A new heart positioner (Tentacles) was tested. Methods: In a prospective clinical study we used the Tentacles device in 50 patients scheduled for multivessel OPCAB procedures and investigated the haemodynamic effects during displacement of the heart and while performing the anastomoses to the anterior, lateral and posterior wall. The following haemodynamic parameters were investigated: mean arterial blood pressure (MAP), cardiac index (CI) and stroke volume index (SVI). The incidence of myocardial ischaemia was monitored by transoesophageal echocardiography (TEE) and by ST-segment analysis in the electrocardiogram (ECG). Result: The Tentacles device permitted rapid, secure and excellent exposure of the lateral and posterior wall of the heart. During exposure of the anterior wall there was a small decrease in MAP (77 +/- 10 vs. 71 +/- 9 mmHg, p = 0.02) in combination with an increase in the CI (3.0 +/- 0.7 l vs. 3.1 +/- 0.8 l/min/m(2), p = 0.03). When the lateral and posterior walls of the heart were exposed, the SVI decreased significantly (36 +/- 11 and 38 +/- 8 mL/m(2), p < 0.01 and p = 0.04, respectively) compared to baseline (44 +/- 11 mL/m(2)) while CI and MAP remained stable. The amount of norepinephrine administered during displacement of the heart was significantly higher in all three positions (0.05 +/- 0.05, 0.06 +/- 0.05 and 0.04 +/- 0.03 mu g/kg/min, p < 0.01) compared to the physiological position (0.02 +/- 0.02 mu g/kg/min). Sinus rhythm was maintained throughout the operation. Neither significant changes of the ST-segment in the ECG nor incidences of wall motion abnormality in TEE were observed. Six hours postoperatively the troponin I concentration was 11.7 +/- 4.3 ng/mL. Conclusion: The Tentacles device provided excellent access in multivessel OPCAB surgery. Haemodynamic stability was maintained in all patients; however additional catecholamine support was used when the heart was displaced. This was the case when carrying out an anastomosis on the anterior, lateral, or posterior wall.
引用
收藏
页码:217 / 221
页数:5
相关论文
共 26 条
  • [1] *AM HEART ASS, 2007, HEART DIS STROK STAT
  • [2] A New Multisuction Cardiac Positioner for Multivessel Off-Pump Coronary Artery Bypass Grafting
    Arai, Hirokuni
    Mizuno, Tomohiro
    Yoshizaki, Tomoya
    Itoh, Fusahiko
    Oi, Keiji
    Someya, Takeshi
    Tanaka, Hiroyuki
    Sunamori, Makoto
    [J]. INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY, 2006, 1 (03) : 126 - 130
  • [3] Beckman D, 2003, HEART SURG FORUM, V6, P220
  • [4] Hemodynamic changes during posterior vessel off-pump coronary artery bypass: Comparison between deep pericardial sutures and vacuum-assisted apical suction device
    Chang, WK
    Kim, KB
    Kim, JH
    Ham, BM
    Kim, YL
    [J]. ANNALS OF THORACIC SURGERY, 2004, 78 (06) : 2057 - 2062
  • [5] Off-pump coronary surgery: Effect on early mortality and stroke
    Cheng, W
    Denton, TA
    Fontana, GP
    Raissi, S
    Blanche, C
    Kass, RM
    Magliato, KE
    Mirocha, J
    Trento, A
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2002, 124 (02) : 313 - 320
  • [6] Off-pump coronary artery bypass grafting decreases risk-adjusted mortality and morbidity
    Cleveland, JC
    Shroyer, ALW
    Chen, AY
    Peterson, E
    Grover, FL
    [J]. ANNALS OF THORACIC SURGERY, 2001, 72 (04) : 1282 - 1288
  • [7] Connolly MW, 2004, MINIMALLY INVASIVE C, P105
  • [8] Dullum MKC, 2000, HEART SURG FORUM, V3, P113
  • [9] Ninety-degree anterior cardiac displacement in off-pump coronary artery bypass grafting:: The starfish cardiac positioner preserves stroke volume and arterial pressure
    Gründeman, PF
    Verlaan, CWJ
    van Boven, WJ
    Borst, C
    [J]. ANNALS OF THORACIC SURGERY, 2004, 78 (02) : 679 - 685
  • [10] Exposure of circumflex branches in the tilted, beating porcine heart:: Echocardiographic evidence of right ventricular deformation and the effect of right or left heart bypass
    Gründeman, PF
    Borst, C
    Verlaan, CWJ
    Meijburg, H
    Mouës, CM
    Jansen, EWL
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1999, 118 (02) : 316 - 323