Automated amplified flow immunoassay for cocaine

被引:56
作者
Bauer, CG
Eremenko, AV
Kühn, A
Kürzinger, K
Makower, A
Scheller, FW
机构
[1] Univ Potsdam, Inst Biochem & Mol Physiol, D-14943 Luckenwalde, Germany
[2] Boehringer Mannheim GmbH, Diagnost Lab, D-82377 Penzberg, Germany
关键词
D O I
10.1021/ac971388s
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An amplified now immunoassay (AFIA) was developed for cocaine, which combines a noncompetitive immunoenzymometric assay (IEMA) with an on-line detection of the enzyme label alkaline phosphatase (ALP) by a substratere-cycling biosensor. In the IEMA, the analyte cocaine first binds to a labeled polyclonal anti-cocaine antibody. Then, the excess labeled antibody is separated on an affinity column that contains a perfusion chromatography carrier modified by immobilized cocaine. The unbound complexes of the analyte cocaine with the ALP-labeled antibody are detected postcolumn, The detector senses phenol produced by ALP from phenyl phosphate. As detector, an amperometric substrate-recycling biosensor was used, which consists of a Clark-type oxygen electrode covered by tyrosinase and pyrroloquinoline quinone-dependent glucose dehydrogenase. The lower limit of detection is 380 pM (38 fmol) for cocaine. The sampling rate is 26/h. Cocaine could be detected from "real samples" with an imprecision of +/-10% (it = 3) and with a recovery of 49 +/- 3% for various concentrations. AFIA is generally important as a new approach for the fast detection of picomolar concentrations of haptens.
引用
收藏
页码:4624 / 4630
页数:7
相关论文
共 53 条
[41]   MICROBIAL SENSORS BASED ON RESPIRATION MEASUREMENTS [J].
RIEDEL, K ;
NEUMANN, B ;
SCHELLER, F .
CHEMIE INGENIEUR TECHNIK, 1992, 64 (06) :518-528
[42]  
Scheller FW, 1995, ACS SYM SER, V613, P70
[43]   CAPILLARY ELECTROPHORESIS-BASED IMMUNOASSAY FOR CORTISOL IN SERUM [J].
SCHMALZING, D ;
NASHABEH, W ;
YAO, XW ;
MHATRE, R ;
REGNIER, FE ;
AFEYAN, NB ;
FUCHS, M .
ANALYTICAL CHEMISTRY, 1995, 67 (03) :606-612
[44]  
Spiehler V, 1996, CLIN CHEM, V42, P34
[45]  
STANDEFER JC, 1978, CLIN CHEM, V24, P1903
[46]   AMPEROMETRIC ENZYME-AMPLIFIED IMMUNOASSAYS [J].
STANLEY, CJ ;
COX, RB ;
CARDOSI, MF ;
TURNER, APF .
JOURNAL OF IMMUNOLOGICAL METHODS, 1988, 112 (02) :153-161
[47]   REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF COCAINE IN PLASMA AND HUMAN HAIR WITH DIRECT FLUOROMETRIC DETECTION [J].
TAGLIARO, F ;
ANTONIOLI, C ;
DEBATTISTI, Z ;
GHIELMI, S ;
MARIGO, M .
JOURNAL OF CHROMATOGRAPHY A, 1994, 674 (1-2) :207-215
[48]   SIMULTANEOUS ASSAY OF COCAINE, HEROIN AND METABOLITES IN HAIR, PLASMA, SALIVA AND URINE BY GAS-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
WANG, WL ;
DARWIN, WD ;
CONE, EJ .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1994, 660 (02) :279-290
[49]   NEW COCAINE-SELECTIVE MEMBRANE-ELECTRODE [J].
WATANABE, K ;
OKADA, K ;
ODA, H ;
FURUNO, K ;
GOMITA, Y ;
KATSU, T .
ANALYTICA CHIMICA ACTA, 1995, 316 (03) :371-375
[50]   Amperometric immunosensor for the detection of 2,4-dichlorophenoxyacetic acid (2,4-D) in water [J].
Wilmer, M ;
Trau, D ;
Renneberg, R ;
Spener, F .
ANALYTICAL LETTERS, 1997, 30 (03) :515-525