Automated amplified flow immunoassay for cocaine

被引:56
作者
Bauer, CG
Eremenko, AV
Kühn, A
Kürzinger, K
Makower, A
Scheller, FW
机构
[1] Univ Potsdam, Inst Biochem & Mol Physiol, D-14943 Luckenwalde, Germany
[2] Boehringer Mannheim GmbH, Diagnost Lab, D-82377 Penzberg, Germany
关键词
D O I
10.1021/ac971388s
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An amplified now immunoassay (AFIA) was developed for cocaine, which combines a noncompetitive immunoenzymometric assay (IEMA) with an on-line detection of the enzyme label alkaline phosphatase (ALP) by a substratere-cycling biosensor. In the IEMA, the analyte cocaine first binds to a labeled polyclonal anti-cocaine antibody. Then, the excess labeled antibody is separated on an affinity column that contains a perfusion chromatography carrier modified by immobilized cocaine. The unbound complexes of the analyte cocaine with the ALP-labeled antibody are detected postcolumn, The detector senses phenol produced by ALP from phenyl phosphate. As detector, an amperometric substrate-recycling biosensor was used, which consists of a Clark-type oxygen electrode covered by tyrosinase and pyrroloquinoline quinone-dependent glucose dehydrogenase. The lower limit of detection is 380 pM (38 fmol) for cocaine. The sampling rate is 26/h. Cocaine could be detected from "real samples" with an imprecision of +/-10% (it = 3) and with a recovery of 49 +/- 3% for various concentrations. AFIA is generally important as a new approach for the fast detection of picomolar concentrations of haptens.
引用
收藏
页码:4624 / 4630
页数:7
相关论文
共 53 条
[1]   FLOW-INJECTION ENZYME-IMMUNOASSAY OF HAPTENS WITH ENHANCED CHEMILUMINESCENCE DETECTION [J].
AREFYEV, AA ;
VLASENKO, SB ;
EREMIN, SA ;
OSIPOV, AP ;
EGOROV, AM .
ANALYTICA CHIMICA ACTA, 1990, 237 (02) :285-289
[2]  
Barat SA, 1996, J APPL TOXICOL, V16, P215
[3]   Zeptomole-detecting biosensor for alkaline phosphatase in an electrochemical immunoassay for 2,4-dichlorophenoxyacetic acid [J].
Bauer, CG ;
Eremenko, AV ;
EhrentreichForster, E ;
Bier, FF ;
Makower, A ;
Halsall, HB ;
Heineman, WR ;
Scheller, FW .
ANALYTICAL CHEMISTRY, 1996, 68 (15) :2453-2458
[4]   An enzymatic amplification cycle for high sensitive immunoassay [J].
Bier, FF ;
EhrentreichForster, E ;
Makower, A ;
Scheller, FW .
ANALYTICA CHIMICA ACTA, 1996, 328 (01) :27-32
[5]  
Bier FF, 1996, FRESEN J ANAL CHEM, V354, P861
[6]  
Cardenas S, 1996, RAPID COMMUN MASS SP, V10, P631, DOI 10.1002/(SICI)1097-0231(199604)10:6<631::AID-RCM524>3.0.CO
[7]  
2-T
[8]  
CHEN P, 1994, RES COMMUN SUBSTANCE, V15, P71
[9]   Microchip-based capillary electrophoresis for immunoassays: Analysis of monoclonal antibodies and theophylline [J].
Chiem, N ;
Harrison, DJ .
ANALYTICAL CHEMISTRY, 1997, 69 (03) :373-378
[10]  
CONE EJ, 1994, CLIN CHEM, V40, P1299