Application of single shot free-breathing fast imaging employing steady state sequence in cardiac magnetic resonance imaging

被引:1
|
作者
Wang, Lidong [1 ]
Cheng, Liuquan [2 ]
Fang, Fang [2 ,3 ]
Han, Xiaodong [4 ]
Liu, Aishi [4 ]
Ma, Lin [2 ]
Gao, Peiyi [1 ]
Niu, Guangming [1 ]
机构
[1] Capital Med Univ, Dept Radiol, Beijing Tiantan Hosp, Beijing 100050, Peoples R China
[2] Peoples Liberat Army Gen Hosp, Dept Radiol, Beijing, Peoples R China
[3] 273 Hosp PLA, Dept Cardiol, Korla, Xinjiang, Peoples R China
[4] Inner Mongolia Med Univ, Dept Radiol, Affiliated Hosp, Hohhot, Peoples R China
基金
美国国家科学基金会;
关键词
contrast-enhanced cardiac magnetic resonance; segmented inversion recovery 2D fast gradient echo; segmented inversion recovery 3D fast gradient echo; single-shot inversion recovery fast imaging employing steady state; REVERSIBLE MYOCARDIAL DYSFUNCTION; COMPUTED-TOMOGRAPHY; FREE PRECESSION; INFARCTION; ENHANCEMENT; HEART; MRI; CARDIOLOGY; TRUEFISP; 3.0-T;
D O I
10.1111/cpf.12140
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
ObjectiveTo investigate the imaging quality of single shot (SS) fast imaging employing steady state (FIESTA) sequence in contrast-enhanced cardiac magnetic resonance (MR) examination, in comparison with the segmented inversion recovery 2D fast gradient echo (IR FGRE) sequence. Materials and methodsFifty-two cases with suspected or known heart disease were enrolled in this study, including 24 patients who had enhanced myocardium in myocardial delayed enhancement (MDE). We analyzed the imaging quality of the sequences by measuring the myocardium and blood pool signal-to-noise ratios (SNR) and the contrast-to-noise ratios (CNR) of blood pool relative to normal myocardium and of enhanced myocardium relative to normal myocardium and compared the new sequences with traditional sequence. ResultsThe scanning time of SS FIESTA was significantly shortened as compared to IR FGRE. The differences in the image quality scores, enhanced myocardium (EM) mass and percentages, SNR(bp), SNR(myo), CNR(myo/bp) and CNR(l/bg) were not statistically significant between SS FIESTA and IR FGRE (P>005). However, the difference in CNR(em/myo) was statistically significant between SS FIESTA and IR FGRE (P<00001), with CNR(em/myo) of IR FGRE higher than SS FIESTA. ConclusionSingle shot FIESTA speeded up the acquisition time, halving it to (276 +/- 18s) instead of 146+138s (IR FGRE), it had higher SNR and CNR, and its image quality did not differ significantly from IR FGRE. The SS FIESTA is more suitable for patients with severely heart diseases or those unable to hold breath. 3D IR FGRE sequence had higher SNR(myo) than the others and it is suitable for displaying the subendocardial scar. However, it has more artefacts and poor imaging quality than IR FGRE.
引用
收藏
页码:159 / 166
页数:8
相关论文
共 50 条
  • [1] A Deep Learning Segmentation Approach in Free-Breathing Real-Time Cardiac Magnetic Resonance Imaging
    Yang, Fan
    Zhang, Yan
    Lei, Pinggui
    Wang, Lihui
    Miao, Yuehong
    Xie, Hong
    Zeng, Zhu
    BIOMED RESEARCH INTERNATIONAL, 2019, 2019
  • [2] Utility of single-shot compressed sensing cardiac magnetic resonance cine imaging for assessment of biventricular function in free-breathing and arrhythmic pediatric patients
    Zou, Qing
    Xu, Hua-yan
    Fu, Chuan
    Zhou, Xiao-yue
    Xu, Rong
    Yang, Meng-xi
    Yang, Zhi-gang
    Guo, Ying-kun
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2021, 338 : 258 - 264
  • [3] 3D free-breathing cardiac magnetic resonance fingerprinting
    Cruz, Gastao
    Jaubert, Olivier
    Qi, Haikun
    Bustin, Aurelien
    Milotta, Giorgia
    Schneider, Torben
    Koken, Peter
    Doneva, Mariya
    Botnar, Rene M.
    Prieto, Claudia
    NMR IN BIOMEDICINE, 2020, 33 (10)
  • [4] Comparative assessment of motion averaged free-breathing or breath-held cardiac magnetic resonance imaging protocols in a porcine myocardial infarction model
    Selvakumar, Dinesh
    Deshmukh, Tejas
    Foster, Sheryl L.
    Sanaei, Naeim N.
    Min, Anthea L. L.
    Grieve, Stuart M.
    Pathan, Faraz
    Chong, James J. H.
    SCIENTIFIC REPORTS, 2022, 12 (01):
  • [5] Validation of cardiac magnetic-resonance-derived left ventricular strain measurements from free-breathing motion-corrected cine imaging
    Merlocco, Anthony
    Cross, Russell R.
    Kellman, Peter
    Xue, Hui
    Olivieri, Laura
    PEDIATRIC RADIOLOGY, 2019, 49 (01) : 68 - 75
  • [6] Accuracy and effectiveness of self-gating signals in free-breathing three-dimensional cardiac cine magnetic resonance imaging
    Li, Shuo
    Wang, Lei
    Zhu, Yan-Chun
    Yang, Jie
    Xie, Yao-Qin
    Fu, Nan
    Wang, Yi
    Gao, Song
    CHINESE PHYSICS B, 2016, 25 (12)
  • [7] Dynamic MR imaging of temporomandibular joint: an initial assessment with fast imaging employing steady-state acquisition sequence
    Sun, Qi
    Dong, Min-jun
    Tao, Xiao-feng
    Yu, Qiang
    Li, Kai-cheng
    Yang, Chi
    MAGNETIC RESONANCE IMAGING, 2015, 33 (03) : 270 - 275
  • [8] Radial fast interrupted steady-state (FISS) magnetic resonance imaging
    Koktzoglou, Ioannis
    Edelman, Robert R.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (04) : 2077 - 2086
  • [9] Convolutional Neural Network for the Detection of End-Diastole and End-Systole Frames in Free-Breathing Cardiac Magnetic Resonance Imaging
    Yang, Fan
    He, Yan
    Hussain, Mubashir
    Xie, Hong
    Lei, Pinggui
    COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2017, 2017
  • [10] Assessment of deep learning segmentation for real-time free-breathing cardiac magnetic resonance imaging at rest and under exercise stress
    Schilling, Martin
    Unterberg-Buchwald, Christina
    Lotz, Joachim
    Uecker, Martin
    SCIENTIFIC REPORTS, 2024, 14 (01)