Comparison of the accuracy of dental implant placement using static and dynamic computer-assisted systems: an in vitro study

被引:15
|
作者
Zhou, Miao [1 ]
Zhou, Hui [1 ,2 ]
Li, Shu-Yi [1 ]
Zhu, Yi-Bo [3 ]
Geng, Yuan-Ming [4 ]
机构
[1] Guangzhou Med Univ, Affiliated Stomatol Hosp, Dept Oral & Maxillofacial Surg, Guangzhou Key Lab Basic & Appl Res Oral Regenerat, Huangshadadao Rd 39, Guangzhou 510182, Peoples R China
[2] Eighth People Hosp Guangzhou, Dept Stomatol, Huayinglu Rd 8, Guangzhou 510060, Peoples R China
[3] Peking Univ, Dent Ctr 4, Sch & Hosp Stomatol, Dongsihuanzhonglu Rd 41, Beijing 100025, Peoples R China
[4] Southern Med Univ, Zhujiang Hosp, Dept Stomatol, Gongyedadaozhong Rd 253, Guangzhou 510282, Peoples R China
基金
中国国家自然科学基金;
关键词
Dental implant; Computer-assisted system; Accuracy; Model study; REGISTRATION METHODS; GUIDED SURGERY; NAVIGATION; TEMPLATE; CAD/CAM; BONE;
D O I
10.1016/j.jormas.2020.11.008
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The study aimed to compare the accuracy of implant placement between static and dynamic computer-assisted systems (CAS) in a partially edentulous mandible model. Materials & Methods: A total of 80 implants was placed in mandible models. The implants were placed using either static or dynamic computer-assisted system. Deviations of implant hex, apex and angulation were measured between preoperative planning and postoperative CBCT in planning software. Results: The mean deviations of implant hex, apex and angulation in static CAS group were 1.15 +/- 0.34 mm, 1.37 +/- 0.38 mm and 2.60 +/- 1.11 degree, while in dynamic CAS group were 0.40 +/- 0.41 mm, 0.34 +/- 0.33 mm and 0.97 +/- 1.21 degree, respectively. Implant placement with dynamic CAS showed less deviations of shoulder, apex and angulation than with static CAS significantly. Conclusions: The implant accuracy using CAS system could be influenced by the guiding technique. (C) 2020 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:343 / 348
页数:6
相关论文
共 50 条
  • [21] Accuracy of Different Surgical Guide Designs for Static Computer-Assisted Implant Surgery: An In Vitro Study
    Wu, Yu Tsung
    Papaspyridakos, Panos
    Kang, Kiho
    Finkelman, Matthew
    Kudara, Yukio
    De Souza, Andre B.
    JOURNAL OF ORAL IMPLANTOLOGY, 2022, 48 (05) : 351 - 357
  • [22] Accuracy of dynamic computer-assisted implant surgery in fully edentulous patients: An in vitro study
    Ruiz-Romero, Victor
    Jorba-Garcia, Adria
    Camps-Font, Octavi
    Figueiredo, Rui
    Valmaseda-Castellon, Eduard
    JOURNAL OF DENTISTRY, 2024, 149
  • [23] Accuracy of open-sleeved vs. closed-sleeved static computer-assisted implant systems in immediate maxillary molar implant placement: An in vitro study
    Chen, Zhaozhao
    Li, Junying
    Wei, Chen Xuan
    Mendonca, Gustavo
    Wang, Hom-Lay
    CLINICAL ORAL IMPLANTS RESEARCH, 2024, 35 (07) : 694 - 705
  • [24] Comparison of precision of implant placement between two different guided systems for static computer-assisted implant surgery: A simulation-based experimental study
    Pattanasirikun, Papon
    Arunjaroensuk, Sirida
    Panya, Sappasith
    Subbalekha, Keskanya
    Mattheos, Nikos
    Pimkhaokham, Atiphan
    JOURNAL OF DENTAL SCIENCES, 2024, 19 : S38 - S43
  • [25] Accuracy and patient-centered results of static and dynamic computer-assisted implant surgery in edentulous jaws: a retrospective cohort study
    Fu, Shuang
    Sun, Wei
    Zhu, Jingxian
    Huang, Bin
    Ji, Wei
    Shi, Bin
    CLINICAL ORAL INVESTIGATIONS, 2023, 27 (09) : 5427 - 5438
  • [26] In vitro and in vivo accuracy of autonomous robotic vs. fully guided static computer-assisted implant surgery
    He, Jin
    Zhang, Qinmeng
    Wang, Xueting
    Fu, Mengdie
    Zhang, Hui
    Song, Luyao
    Pu, Rui
    Jiang, Zhiwei
    Yang, Guoli
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2024, 26 (02) : 385 - 401
  • [27] Accuracy assessment of computer-assisted flapless implant placement in partial edentulism
    Van Assche, N.
    van Steenberghe, D.
    Quirynen, M.
    Jacobs, R.
    JOURNAL OF CLINICAL PERIODONTOLOGY, 2010, 37 (04) : 398 - 403
  • [28] Accuracy of robotic computer-assisted implant surgery for immediate implant placement: A retrospective case series study
    Li, Ping
    Zhao, Chunhui
    Chen, Jiahao
    Xu, Shulan
    Yang, Shuo
    Li, An
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2024, 26 (06) : 1279 - 1288
  • [29] Comparison of Dental Surface Image Registration and Fiducial Marker Registration: An In Vivo Accuracy Study of Static Computer-Assisted Implant Surgery
    Han, Yen-Ting
    Lin, Wei-Chun
    Fan, Fang-Yu
    Chen, Chih-Long
    Lin, Chia-Cheng
    Cheng, Hsin-Chung
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (18)
  • [30] In Vivo and In Vitro Accuracy Analysis of Static Computer-Assisted Implant Surgery in an Edentulous Patient
    Makarov, Nikolay
    Papi, Piero
    Santomauro, Vincenzo
    Di Carlo, Gabriele
    Polimeni, Antonella
    Di Murro, Bianca
    Saccucci, Matteo
    APPLIED SCIENCES-BASEL, 2023, 13 (02):